Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.0_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 386bd345717017b3ce66ee3c5a6222e0cd3bbc7e 359f4d84608c44541c43bfc564893ac76c326063 (HEAD -] onos-2.0, origin/onos-2.0)
Author: gyewan.an [gyewan.an@samsung.Jon Hall [jhall@ciena.com]
AuthorDate: Mon Dec 24 11:47:57 2018 +0900Tue Jan 8 16:17:24 2019 -0800
Commit: Andrea Campanella Ray Milkey [andrea@opennetworkingray@opennetworking.org]
CommitDate: Wed Thu Jan 9 10 23:5330:39 32 2019 +0000
Implementation Cisco rest driver for Nexus 900
--
(cherry picked from commit a7d7bd95a1cbb16311dac72b08fedc557850d2bb)
(cherry picked from commit c7d9077049a783f23f03e615bb7b517675a394a1)
Allow use of rsync when fetching logs
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - PASS
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS
Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling Atomix - PASS
- 33.3 Uninstalling ONOS package - PASS
- 33.4 Installing Atomix - PASS
- 33.5 Installing ONOS package - PASS
- 33.6 Set up ONOS secure SSH - PASS
- 33.7 Checking ONOS service - PASS
- 33.8 Starting ONOS CLI sessions - PASS
- 33.9 Checking ONOS nodes - PASS
- 33.10 Checking ONOS applications - PASS
- 33.11 Starting Mininet Topology - PASS
- 33.12 Check whether the flow count is bigger than 104 - PASS
- 33.13 Check whether all flow status are ADDED - PASS
- 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS
- 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS
- 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 33.18 Check whether the flow count is bigger than 104 - PASS
- 33.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS
- 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS
- 33.22 Stopping Mininet - PASS
- 33.23 Copying karaf logs - PASS
...
- 183.1 Apply cell to environment - PASS
- 183.2 Uninstalling Atomix - PASS
- 183.3 Uninstalling ONOS package - PASS
- 183.4 Installing Atomix - PASS
- 183.5 Installing ONOS package - PASS
- 183.6 Set up ONOS secure SSH - PASS
- 183.7 Checking ONOS service - PASS
- 183.8 Starting ONOS CLI sessions - PASS
- 183.9 Checking ONOS nodes - PASS
- 183.10 Checking ONOS applications - PASS
- 183.11 Starting Mininet Topology - PASS
- 183.12 Check whether the flow count is bigger than 106 - PASS
- 183.13 Check whether all flow status are ADDED - PASS
- 183.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS
- 183.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS
- 183.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 183.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 183.18 Check whether the flow count is bigger than 106 - PASS
- 183.19 Check whether all flow status are ADDED - PASS
- 183.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS
- 183.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS
- 183.22 Stopping Mininet - PASS
- 183.23 Copying karaf logs - PASS
Case 193: Changing port configuration from tagged 20 and native 10 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 193.1 Apply cell to environment - PASS
- 193.2 Uninstalling Atomix - PASS
- 193.3 Uninstalling ONOS package - PASS
- 193.4 Installing Atomix - PASS
- 193.5 Installing ONOS package - PASS
- 193.6 Set up ONOS secure SSH - PASS
- 193.7 Checking ONOS service - PASS
- 193.8 Starting ONOS CLI sessions - PASS
- 193.9 Checking ONOS nodes - PASS
- 193.10 Checking ONOS applications - PASS
- 193.11 Starting Mininet Topology - PASS
- 193.12 Check whether the flow count is bigger than 106 - PASS
- 193.13 Check whether all flow status are ADDED - PASS
- 193.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - FAIL IP connectivity failed
- PASS
- 193.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS
- 193.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 193.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 193.18 Check whether the flow count is bigger than 106 - PASS
- 193.19 Check whether all flow status are ADDED - PASS
- 193.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS
- 193.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS
- 193.22 Stopping Mininet - PASS
- 193.23 Copying karaf logs - PASS
...