commit a10f675028d2b297fb63b1fd4af1aade37801156 a60a2d9124f00e4cf7d8575a2756bac627fe9129 (HEAD -] onos-2.0, origin/onos-2.0)
Author: Carmelo Cascone Andrea Campanella [carmelo@opennetworkingandrea@opennetworking.org]
AuthorDate: Tue Sep Jan 15 11 15:17:23 2018 -070010:44 2019 +0100
Commit: Carmelo Cascone Thomas Vachuska [carmelo@opennetworkingtom@opennetworking.org]
CommitDate: Mon Tue Jan 14 1315 23:5501:26 48 2019 -0800+0000
ONOS-7887 Rename action profile-related entities
[ONOS-7882] Updating Yang Tools to 2.6.1 to address JSON serialization issue
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Starting Mininet Topology - PASS
- 27.12 Check whether the flow count is bigger than 74 - PASS
- 27.13 Check whether all flow status are ADDED - PASS
- 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS
- 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS
- 27.18 Stopping Mininet - PASS
- 27.19 Copying karaf logs - PASS
Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 28.1 Apply cell to environment - PASS
- 28.2 Uninstalling Atomix - PASS
- 28.3 Uninstalling ONOS package - PASS
- 28.4 Installing Atomix - PASS
- 28.5 Installing ONOS package - PASS
- 28.6 Set up ONOS secure SSH - PASS
- 28.7 Checking ONOS service - PASS
- 28.8 Starting ONOS CLI sessions - PASS
- 28.9 Checking ONOS nodes - PASS
- 28.10 Checking ONOS applications - PASS
- 28.11 Starting Mininet Topology - PASS
- 28.12 Check whether the flow count is bigger than 212 - PASS
- 28.13 Check whether all flow status are ADDED - PASS
- 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL Flow count looks wrong.
- PASS
- 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS
- 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - FAIL
- IP connectivity failed
- PASS
- 28.20 Stopping Mininet - PASS
- 28.21 Copying karaf logs - PASS
...
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling Atomix - PASS
- 48.3 Uninstalling ONOS package - PASS
- 48.4 Installing Atomix - PASS
- 48.5 Installing ONOS package - PASS
- 48.6 Set up ONOS secure SSH - PASS
- 48.7 Checking ONOS service - PASS
- 48.8 Starting ONOS CLI sessions - PASS
- 48.9 Checking ONOS nodes - PASS
- 48.10 Checking ONOS applications - PASS
- 48.11 Starting Mininet Topology - PASS
- 48.12 Check whether the flow count is bigger than 212 - PASS
- 48.13 Check whether all flow status are ADDED - PASS
- 48.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 48.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 48.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 48.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 48.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS
- 48.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS
- 48.20 Stopping Mininet - PASS
- 48.21 Copying karaf logs - PASS
Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR and 3 ONOS instances -
...
FAIL
- 55.1 Apply cell to environment - PASS
- 55.2 Uninstalling Atomix - PASS
- 55.3 Uninstalling ONOS package - PASS
- 55.4 Installing Atomix - PASS
- 55.5 Installing ONOS package - PASS
- 55.6 Set up ONOS secure SSH - PASS
- 55.7 Checking ONOS service - PASS
- 55.8 Starting ONOS CLI sessions - PASS
- 55.9 Checking ONOS nodes - PASS
- 55.10 Checking ONOS applications - PASS
- 55.11 Starting Mininet Topology - PASS
- 55.12 Check whether the flow count is bigger than 28 - PASS FAIL
- Flow count looks wrong: False
- 55.13 Check whether all flow status are ADDED - PASS
- 55.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS FAIL
- Flow count looks wrong.
- 55.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS
- 55.16 Stopping Mininet - PASS
- 55.17 Copying karaf logs - PASS
Case 56: Bridging test between two untagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances -
...
FAIL
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Installing Atomix - PASS
- 56.5 Installing ONOS package - PASS
- 56.6 Set up ONOS secure SSH - PASS
- 56.7 Checking ONOS service - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Starting Mininet Topology - PASS
- 56.12 Check whether the flow count is bigger than 74 - PASS FAIL
- Flow count looks wrong: False
- 56.13 Check whether all flow status are ADDED - PASS
- 56.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS FAIL
- Flow count looks wrong.
- 56.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS FAIL
- Flow count looks wrong.
- 56.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.17 Stopping Mininet - PASS
- 56.18 Copying karaf logs - PASS
...