- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Starting Mininet Topology - PASS
- 6.12 Check whether the flow count is bigger than 74 - PASS
- 6.13 Check whether all flow status are ADDED - PASS
- 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS
- 6.17 Stopping Mininet - PASS
- 6.18 Copying karaf logs - PASS
Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 7.1 Apply cell to environment - PASS
- 7.2 Uninstalling Atomix - PASS
- 7.3 Uninstalling ONOS package - PASS
- 7.4 Installing Atomix - PASS
- 7.5 Installing ONOS package - PASS
- 7.6 Set up ONOS secure SSH - PASS
- 7.7 Checking ONOS service - PASS
- 7.8 Starting ONOS CLI sessions - PASS
- 7.9 Checking ONOS nodes - PASS
- 7.10 Checking ONOS applications - PASS
- 7.11 Starting Mininet Topology - PASS
- 7.12 Check whether the flow count is bigger than 74 - PASS
- 7.13 Check whether all flow status are ADDED - PASS
- 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS
- 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - FAIL
- PASS
- 7.18 Stopping Mininet - PASS
- 7.19 Copying karaf logs - PASS
...
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling Atomix - PASS
- 48.3 Uninstalling ONOS package - PASS
- 48.4 Installing Atomix - PASS
- 48.5 Installing ONOS package - PASS
- 48.6 Set up ONOS secure SSH - PASS
- 48.7 Checking ONOS service - PASS
- 48.8 Starting ONOS CLI sessions - PASS
- 48.9 Checking ONOS nodes - PASS
- 48.10 Checking ONOS applications - PASS
- 48.11 Starting Mininet Topology - PASS
- 48.12 Check whether the flow count is bigger than 212 - PASS
- 48.13 Check whether all flow status are ADDED - PASS
- 48.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 48.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 48.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 48.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 48.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS
- 48.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS
- 48.20 Stopping Mininet - PASS
- 48.21 Copying karaf logs - PASS
Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR and 3 ONOS instances -
...
FAIL
- 55.1 Apply cell to environment - PASS
- 55.2 Uninstalling Atomix - PASS
- 55.3 Uninstalling ONOS package - PASS
- 55.4 Installing Atomix - PASS
- 55.5 Installing ONOS package - PASS
- 55.6 Set up ONOS secure SSH - PASS
- 55.7 Checking ONOS service - PASS
- 55.8 Starting ONOS CLI sessions - PASS
- 55.9 Checking ONOS nodes - PASS
- 55.10 Checking ONOS applications - PASS
- 55.11 Starting Mininet Topology - PASS
- 55.12 Check whether the flow count is bigger than 28 - PASS
FAIL
- Flow count looks wrong: False
- 55.13 Check whether all flow status are ADDED - PASS
- 55.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
FAIL
- Flow count looks wrong.
- 55.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS
- 55.16 Stopping Mininet - PASS
- 55.17 Copying karaf logs - PASS
...