commit 6d1cb159fd06efc94de8d88149669ecacc26ad5b 894ff117f741c735697632a070e0185cb65dc491 (HEAD -] onos-2.0, origin/onos-2.0)
Author: Carmelo Cascone [carmelo@opennetworking.org]
AuthorDate: Mon Wed Feb 4 6 17:23:11:26 05 2019 -0800
Commit: Carmelo Cascone [carmelo@opennetworking.org]
CommitDate: Tue Thu Feb 5 227 20:2900:12 50 2019 +0000
Enhanced gRPC call logging
Set all write responses as failed when P4Runtime server returns error
--
(cherry picked from commit 73f4530c389477352c6ea92d42c94d46fa3f0630b203b648185d88868a05567203597c8c0dead092)
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Starting Mininet Topology - PASS
- 27.12 Check whether the flow count is bigger than 74 - PASS
- 27.13 Check whether all flow status are ADDED - PASS
- 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS
- 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS
- 27.18 Stopping Mininet - PASS
- 27.19 Copying karaf logs - PASS
Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 28.1 Apply cell to environment - PASS
- 28.2 Uninstalling Atomix - PASS
- 28.3 Uninstalling ONOS package - PASS
- 28.4 Installing Atomix - PASS
- 28.5 Installing ONOS package - PASS
- 28.6 Set up ONOS secure SSH - PASS
- 28.7 Checking ONOS service - PASS
- 28.8 Starting ONOS CLI sessions - PASS
- 28.9 Checking ONOS nodes - PASS
- 28.10 Checking ONOS applications - PASS
- 28.11 Starting Mininet Topology - PASS
- 28.12 Check whether the flow count is bigger than 212 - FAIL Flow count looks wrong: 18
- PASS
- 28.13 Check whether all flow status are ADDED - PASS
- 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - FAIL IP connectivity failed
- PASS
- 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - FAIL IP connectivity failed
- PASS
- 28.20 Stopping Mininet - PASS
- 28.21 Copying karaf logs - PASS
...
- 65.1 Apply cell to environment - PASS
- 65.2 Uninstalling Atomix - PASS
- 65.3 Uninstalling ONOS package - PASS
- 65.4 Installing Atomix - PASS
- 65.5 Installing ONOS package - PASS
- 65.6 Set up ONOS secure SSH - PASS
- 65.7 Checking ONOS service - PASS
- 65.8 Starting ONOS CLI sessions - PASS
- 65.9 Checking ONOS nodes - PASS
- 65.10 Checking ONOS applications - PASS
- 65.11 Starting Mininet Topology - PASS
- 65.12 Check whether the flow count is bigger than 28 - PASS
- 65.13 Check whether all flow status are ADDED - PASS
- 65.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 65.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS
- 65.16 Stopping Mininet - PASS
- 65.17 Copying karaf logs - PASS
Case 66: Bridging test between two tagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances -
...
PASS
- 66.1 Apply cell to environment - PASS
- 66.2 Uninstalling Atomix - PASS
- 66.3 Uninstalling ONOS package - PASS
- 66.4 Installing Atomix - PASS
- 66.5 Installing ONOS package - PASS
- 66.6 Set up ONOS secure SSH - PASS
- 66.7 Checking ONOS service - PASS
- 66.8 Starting ONOS CLI sessions - PASS
- 66.9 Checking ONOS nodes - PASS
- 66.10 Checking ONOS applications - PASS
- 66.11 Starting Mininet Topology - PASS
- 66.12 Check whether the flow count is bigger than 74 - FAIL Flow count looks wrong: 6
- PASS
- 66.13 Check whether all flow status are ADDED - PASS
- 66.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL
- Flow count looks wrong: 3
- PASS
- 66.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL
- Flow count looks wrong: 3
- PASS
- 66.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS
- 66.17 Stopping Mininet - PASS
- 66.18 Copying karaf logs - PASS
...
- 77.1 Apply cell to environment - PASS
- 77.2 Uninstalling Atomix - PASS
- 77.3 Uninstalling ONOS package - PASS
- 77.4 Installing Atomix - PASS
- 77.5 Installing ONOS package - PASS
- 77.6 Set up ONOS secure SSH - PASS
- 77.7 Checking ONOS service - PASS
- 77.8 Starting ONOS CLI sessions - PASS
- 77.9 Checking ONOS nodes - PASS
- 77.10 Checking ONOS applications - PASS
- 77.11 Starting Mininet Topology - PASS
- 77.12 Check whether the flow count is bigger than 74 - PASS
- 77.13 Check whether all flow status are ADDED - PASS
- 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS
- 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS
- 77.18 Stopping Mininet - PASS
- 77.19 Copying karaf logs - PASS
Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 78.1 Apply cell to environment - PASS
- 78.2 Uninstalling Atomix - PASS
- 78.3 Uninstalling ONOS package - PASS
- 78.4 Installing Atomix - PASS
- 78.5 Installing ONOS package - PASS
- 78.6 Set up ONOS secure SSH - PASS
- 78.7 Checking ONOS service - PASS
- 78.8 Starting ONOS CLI sessions - PASS
- 78.9 Checking ONOS nodes - PASS
- 78.10 Checking ONOS applications - PASS
- 78.11 Starting Mininet Topology - PASS
- 78.12 Check whether the flow count is bigger than 212 - FAIL Flow count looks wrong: 18
- PASS
- 78.13 Check whether all flow status are ADDED - PASS
- 78.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 78.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 78.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 78.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 78.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS
- 78.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS
- 78.20 Stopping Mininet - PASS
- 78.21 Copying karaf logs - PASS