Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.0_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit d678dceffc43a2d789a30379e70a0f32af8fcdb3 303a99b528a1c71fe16bafbc46e2b4398cfad5e4 (HEAD -] onos-2.0, origin/onos-2.0)
Author: Charles Chan [rascov@gmailqphamvan [quan.pham_van@nokia.com]
AuthorDate: Tue Jan 22 17:25:04 2019 -0800Feb 19 14:38:53 2019 +0100
Commit: Charles Chan Andrea Campanella [charles@opennetworkingandrea@opennetworking.org]
CommitDate: Wed Feb 20 0112:1443:06 11 2019 +0000
Deprecate CpqD pipeliners
adding FlowRuleProgrammable for Nokia's transponders
--
(cherry picked from commit 9aedb5685fa10b13ea5f1eb2380bf297c22cb603)
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling Atomix - PASS
- 53.3 Uninstalling ONOS package - PASS
- 53.4 Installing Atomix - PASS
- 53.5 Installing ONOS package - PASS
- 53.6 Set up ONOS secure SSH - PASS
- 53.7 Checking ONOS service - PASS
- 53.8 Starting ONOS CLI sessions - PASS
- 53.9 Checking ONOS nodes - PASS
- 53.10 Checking ONOS applications - PASS
- 53.11 Starting Mininet Topology - PASS
- 53.12 Check whether the flow count is bigger than 104 - PASS
- 53.13 Check whether all flow status are ADDED - PASS
- 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS
- 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS
- 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 53.18 Check whether the flow count is bigger than 104 - PASS
- 53.19 Check whether all flow status are ADDED - PASS
- 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS
- 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS
- 53.22 Stopping Mininet - PASS
- 53.23 Copying karaf logs - PASS
Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Installing Atomix - PASS
- 63.5 Installing ONOS package - PASS
- 63.6 Set up ONOS secure SSH - PASS
- 63.7 Checking ONOS service - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Starting Mininet Topology - PASS
- 63.12 Check whether the flow count is bigger than 104 - PASS
- 63.13 Check whether all flow status are ADDED - PASS
- 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.18 Check whether the flow count is bigger than 104 - PASS
- 63.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.22 Stopping Mininet - PASS
- 63.23 Copying karaf logs - PASS
...
- 103.1 Apply cell to environment - PASS
- 103.2 Uninstalling Atomix - PASS
- 103.3 Uninstalling ONOS package - PASS
- 103.4 Installing Atomix - PASS
- 103.5 Installing ONOS package - PASS
- 103.6 Set up ONOS secure SSH - PASS
- 103.7 Checking ONOS service - PASS
- 103.8 Starting ONOS CLI sessions - PASS
- 103.9 Checking ONOS nodes - PASS
- 103.10 Checking ONOS applications - PASS
- 103.11 Starting Mininet Topology - PASS
- 103.12 Check whether the flow count is bigger than 104 - PASS
- 103.13 Check whether all flow status are ADDED - PASS
- 103.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS
- 103.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 103.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 103.17 Check whether the flow count is bigger than 104 - PASS
- 103.18 Check whether all flow status are ADDED - PASS
- 103.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS
- 103.20 Stopping Mininet - PASS
- 103.21 Copying karaf logs - PASS
Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling Atomix - PASS
- 113.3 Uninstalling ONOS package - PASS
- 113.4 Installing Atomix - PASS
- 113.5 Installing ONOS package - PASS
- 113.6 Set up ONOS secure SSH - PASS
- 113.7 Checking ONOS service - PASS
- 113.8 Starting ONOS CLI sessions - PASS
- 113.9 Checking ONOS nodes - PASS
- 113.10 Checking ONOS applications - PASS
- 113.11 Starting Mininet Topology - PASS
- 113.12 Check whether the flow count is bigger than 104 - PASS
- 113.13 Check whether all flow status are ADDED - PASS
- 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS
- 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS
- 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 113.18 Check whether the flow count is bigger than 104 - PASS
- 113.19 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- PASS
- 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS
- 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.22 Stopping Mininet - PASS
- 113.23 Copying karaf logs - PASS
Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 123.1 Apply cell to environment - PASS
- 123.2 Uninstalling Atomix - PASS
- 123.3 Uninstalling ONOS package - PASS
- 123.4 Installing Atomix - PASS
- 123.5 Installing ONOS package - PASS
- 123.6 Set up ONOS secure SSH - PASS
- 123.7 Checking ONOS service - PASS
- 123.8 Starting ONOS CLI sessions - PASS
- 123.9 Checking ONOS nodes - PASS
- 123.10 Checking ONOS applications - PASS
- 123.11 Starting Mininet Topology - PASS
- 123.12 Check whether the flow count is bigger than 104 - PASS
- 123.13 Check whether all flow status are ADDED - PASS
- 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS
- 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS
- 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 123.18 Check whether the flow count is bigger than 104 - PASS
- 123.19 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS
- 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS
- 123.22 Stopping Mininet - PASS
- 123.23 Copying karaf logs - PASS
...
- 193.1 Apply cell to environment - PASS
- 193.2 Uninstalling Atomix - PASS
- 193.3 Uninstalling ONOS package - PASS
- 193.4 Installing Atomix - PASS
- 193.5 Installing ONOS package - PASS
- 193.6 Set up ONOS secure SSH - PASS
- 193.7 Checking ONOS service - PASS
- 193.8 Starting ONOS CLI sessions - PASS
- 193.9 Checking ONOS nodes - PASS
- 193.10 Checking ONOS applications - PASS
- 193.11 Starting Mininet Topology - PASS
- 193.12 Check whether the flow count is bigger than 106 - PASS
- 193.13 Check whether all flow status are ADDED - PASS
- 193.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS
- 193.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS
- 193.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 193.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 193.18 Check whether the flow count is bigger than 106 - PASS
- 193.19 Check whether all flow status are ADDED - PASS
- 193.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS
- 193.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS
- 193.22 Stopping Mininet - PASS
- 193.23 Copying karaf logs - PASS
Case 203: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 203.1 Apply cell to environment - PASS
- 203.2 Uninstalling Atomix - PASS
- 203.3 Uninstalling ONOS package - PASS
- 203.4 Installing Atomix - PASS
- 203.5 Installing ONOS package - PASS
- 203.6 Set up ONOS secure SSH - PASS
- 203.7 Checking ONOS service - PASS
- 203.8 Starting ONOS CLI sessions - PASS
- 203.9 Checking ONOS nodes - PASS
- 203.10 Checking ONOS applications - PASS
- 203.11 Starting Mininet Topology - PASS
- 203.12 Check whether the flow count is bigger than 106 - PASS
- 203.13 Check whether all flow status are ADDED - PASS
- 203.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_Before - PASS FAIL
- IP connectivity failed
- 203.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_Before - PASS
- 203.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 203.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 203.18 Check whether the flow count is bigger than 106 - PASS
- 203.19 Check whether all flow status are ADDED - PASS
- 203.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE203_After - PASS
- 203.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE203_After - PASS
- 203.22 Stopping Mininet - PASS
- 203.23 Copying karaf logs - PASS
...