- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Starting Mininet Topology - PASS
- 5.14 Check whether the flow count is bigger than 28 - PASS
- 5.15 Check whether all flow status are ADDED - PASS
- 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS
- 5.18 Stopping Mininet - PASS
- 5.19 Copying karaf logs - PASS
Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR and 3 ONOS instances -
...
PASS
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Starting Mininet Topology - PASS
- 6.12 Check whether the flow count is bigger than 74 - PASS
- 6.13 Check whether all flow status are ADDED - PASS
- 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - FAIL
- IP connectivity failed
- PASS
- 6.17 Stopping Mininet - PASS
- 6.18 Copying karaf logs - PASS
...
- 75.1 Apply cell to environment - PASS
- 75.2 Uninstalling Atomix - PASS
- 75.3 Uninstalling ONOS package - PASS
- 75.4 Installing Atomix - PASS
- 75.5 Installing ONOS package - PASS
- 75.6 Set up ONOS secure SSH - PASS
- 75.7 Checking ONOS service - PASS
- 75.8 Starting ONOS CLI sessions - PASS
- 75.9 Checking ONOS nodes - PASS
- 75.10 Checking ONOS applications - PASS
- 75.11 Starting Mininet Topology - PASS
- 75.12 Check whether the flow count is bigger than 28 - PASS
- 75.13 Check whether all flow status are ADDED - PASS
- 75.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 75.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE75 - PASS
- 75.16 Stopping Mininet - PASS
- 75.17 Copying karaf logs - PASS
Case 76: Bridging test between untagged and tagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances -
...
FAIL
- 76.1 Apply cell to environment - PASS
- 76.2 Uninstalling Atomix - PASS
- 76.3 Uninstalling ONOS package - PASS
- 76.4 Installing Atomix - PASS
- 76.5 Installing ONOS package - PASS
- 76.6 Set up ONOS secure SSH - PASS
- 76.7 Checking ONOS service - PASS
- 76.8 Starting ONOS CLI sessions - PASS
- 76.9 Checking ONOS nodes - PASS
- 76.10 Checking ONOS applications - PASS
- 76.11 Starting Mininet Topology - PASS
- 76.12 Check whether the flow count is bigger than 74 - PASS FAIL
- Flow count looks wrong: 6
- 76.13 Check whether all flow status are ADDED - PASS
- 76.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 3
- 76.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS FAIL
- Flow count looks wrong: 3
- 76.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS
- 76.17 Stopping Mininet - PASS
- 76.18 Copying karaf logs - PASS
...