commit d120291cfe7173d5bbb2b7fb098a1eaa22868d97 830507e8a8a7547d02194dce8cde35bb3c421d6d (HEAD -] onos-2.0, origin/onos-2.0)
Author: Andrea Campanella Charles Chan [andrea@opennetworkingrascov@gmail.orgcom]
AuthorDate: Thu Mar 21 11:45:44 2019 -0700Wed Jan 2 13:46:16 2019 -0800
Commit: Andrea Campanella Charles Chan [andrea@opennetworkingrascov@gmail.orgcom]
CommitDate: Tue Sun Mar 26 1731 01:3418:16 2019 +0000
Only one node should be master of initializing the DCS store
--
(cherry picked from commit 566edf3b5d508b3e7fdb1877f936863800738f60)45 2019 -0700
Address comments in gerrit 20328
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS
...
- 27.1 Apply cell to environment - PASS
- 27.2 Uninstalling Atomix - PASS
- 27.3 Uninstalling ONOS package - PASS
- 27.4 Installing Atomix - PASS
- 27.5 Installing ONOS package - PASS
- 27.6 Set up ONOS secure SSH - PASS
- 27.7 Checking ONOS service - PASS
- 27.8 Starting ONOS CLI sessions - PASS
- 27.9 Checking ONOS nodes - PASS
- 27.10 Checking ONOS applications - PASS
- 27.11 Starting Mininet Topology - PASS
- 27.12 Check whether the flow count is bigger than 74 - PASS
- 27.13 Check whether all flow status are ADDED - PASS
- 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS
- 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - PASS
- 27.18 Stopping Mininet - PASS
- 27.19 Copying karaf logs - PASS
Case 28: Bridging test between two untagged hosts on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -
...
PASS
- 28.1 Apply cell to environment - PASS
- 28.2 Uninstalling Atomix - PASS
- 28.3 Uninstalling ONOS package - PASS
- 28.4 Installing Atomix - PASS
- 28.5 Installing ONOS package - PASS
- 28.6 Set up ONOS secure SSH - PASS
- 28.7 Checking ONOS service - PASS
- 28.8 Starting ONOS CLI sessions - PASS
- 28.9 Checking ONOS nodes - PASS
- 28.10 Checking ONOS applications - PASS
- 28.11 Starting Mininet Topology - PASS
- 28.12 Check whether the flow count is bigger than 212 - FAIL
- Flow count looks wrong: 18
- PASS
- 28.13 Check whether all flow status are ADDED - PASS
- 28.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 28.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 28.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL Flow count looks wrong: 3
- PASS
- 28.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL
- Flow count looks wrong: 3
- PASS
- 28.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - FAIL IP connectivity failed
- PASS
- 28.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - FAIL IP connectivity failed
- PASS
- 28.20 Stopping Mininet - PASS
- 28.21 Copying karaf logs - PASS
...