Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.15/1136/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-1.15_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit fe9a094cb3509dd0a70b65a8c0ad70b54dbff818 1d19c9cc70585996aa201d74bfe328c6ffbc312f (HEAD -] onos-1.15, origin/onos-1.15)
Author: pier Ray Milkey [pier@opennetworkingray@opennetworking.org]
AuthorDate: Mon Thu Apr 1 234 12:3800:42 18 2019 -0700
Commit: pier Ray Milkey [pier@opennetworkingray@opennetworking.org]
CommitDate: Wed Thu Apr 3 204 22:5139:36 56 2019 +0200
Remove listeners before shutting down the executors0000

Bump up required bazel version to 0.23

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Starting Mininet Topology - PASS (tick)
  • 17.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.13 Check whether all flow status are ADDED - PASS (tick)
  • 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS (tick)
  • 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS (tick)
  • 17.18 Stopping Mininet - PASS (tick)
  • 17.19 Copying karaf logs - PASS (tick)

Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Starting Mininet Topology - PASS (tick)
  • 18.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 18.13 Check whether all flow status are ADDED - PASS (tick)
  • 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 23
  • 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 18.20 Stopping Mininet - PASS (tick)
  • 18.21 Copying karaf logs - PASS (tick)

...