Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.15_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0"> |
commit 017589427ac26024dd5ff2d6818907e09defbabc bac68786045e673d6155c84a8253420e77aa6706 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Georgios Katsikas [katsikas.gp@gmailJian Li [pyguni@gmail.com]
AuthorDate: Thu Tue May 2 2214 17:3045:16 54 2019 +02000900
Commit: Georgios Katsikas Jian Li [katsikaspyguni@gmail.gp@gmail.com]
CommitDate: Thu Fri May 2 2217 10:3044:16 28 2019 +0200
Set protocol field for server devices
--
in the DeviceView UI. This commit fixes the issue
by passing the protocol as a device annotation.
Change-Id: I9e6343c2e1a1afdd4ffe0accd227fb05f5f3caf7
Signed-off-by: Georgios Katsikas [katsikas.gp@gmail.com]
0000
Refactor external peer router store, fix NPE due to MAC is not ready
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
...
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - PASS
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS
Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling Atomix - PASS
- 33.3 Uninstalling ONOS package - PASS
- 33.4 Installing Atomix - PASS
- 33.5 Installing ONOS package - PASS
- 33.6 Set up ONOS secure SSH - PASS
- 33.7 Checking ONOS service - PASS
- 33.8 Starting ONOS CLI sessions - PASS
- 33.9 Checking ONOS nodes - PASS
- 33.10 Checking ONOS applications - PASS
- 33.11 Starting Mininet Topology - PASS
- 33.12 Check whether the flow count is bigger than 104 - PASS
- 33.13 Check whether all flow status are ADDED - PASS
- 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - FAIL IP connectivity failed
- PASS
- 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - FAIL IP connectivity failed
- PASS
- 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 33.18 Check whether the flow count is bigger than 104 - PASS
- 33.19 Check whether all flow status are ADDED - PASS
- 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - FAIL
- IP connectivity failed
- PASS
- 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS
- 33.22 Stopping Mininet - PASS
- 33.23 Copying karaf logs - PASS
...
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling Atomix - PASS
- 113.3 Uninstalling ONOS package - PASS
- 113.4 Installing Atomix - PASS
- 113.5 Installing ONOS package - PASS
- 113.6 Set up ONOS secure SSH - PASS
- 113.7 Checking ONOS service - PASS
- 113.8 Starting ONOS CLI sessions - PASS
- 113.9 Checking ONOS nodes - PASS
- 113.10 Checking ONOS applications - PASS
- 113.11 Starting Mininet Topology - PASS
- 113.12 Check whether the flow count is bigger than 104 - PASS FAIL
- Flow count looks wrong: 87
- 113.13 Check whether all flow status are ADDED - PASS
- 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS FAIL
- IP connectivity failed
- 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS FAIL
- IP connectivity failed
- 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS FAIL
- Flow count looks wrong: 16
- 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS FAIL
- Flow count looks wrong: 27
- 113.18 Check whether the flow count is bigger than 104 - PASS FAIL
- Flow count looks wrong: 87
- 113.19 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- PASS
- 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS FAIL
- IP connectivity failed
- 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.22 Stopping Mininet - PASS
- 113.23 Copying karaf logs - PASS
Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 123.1 Apply cell to environment - PASS
- 123.2 Uninstalling Atomix - PASS
- 123.3 Uninstalling ONOS package - PASS
- 123.4 Installing Atomix - PASS
- 123.5 Installing ONOS package - PASS
- 123.6 Set up ONOS secure SSH - PASS
- 123.7 Checking ONOS service - PASS
- 123.8 Starting ONOS CLI sessions - PASS
- 123.9 Checking ONOS nodes - PASS
- 123.10 Checking ONOS applications - PASS
- 123.11 Starting Mininet Topology - PASS
- 123.12 Check whether the flow count is bigger than 104 - PASS
- 123.13 Check whether all flow status are ADDED - PASS
- 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS
- 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS
- 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 123.18 Check whether the flow count is bigger than 104 - PASS
- 123.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS
- 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS
- 123.22 Stopping Mininet - PASS
- 123.23 Copying karaf logs - PASS
...