Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.15/1227/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric-1.x/lastSuccessfulBuild/artifact/SRDynamicConf_onos-1.15_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit 3505a14cd2be32e9ef59333a8ea933026a1848d0 bcd65d10c6692d477955d8c87cbbef9ed4047ae9 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Jian Li [pyguni@gmailEsin Karaman [esin.karaman@netsia.com]
AuthorDate: Tue Wed Jul 23 1724 11:1326:19 39 2019 +09000000
Commit: Jian Li [pyguni@gmail.comPier Luigi Ventre [pier@opennetworking.org]
CommitDate: Fri Jul 26 0108:2235:15 13 2019 +0900
Isolate the PODs traffic for each namespace using segment ID0000

SEBA-801 McastHandler of SegmentRouting app. does not install multicast
--
(cherry picked from commit 92920611c0c6cac0eb64587ee0a4bc17c253a120)

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Starting Mininet Topology - PASS (tick)
  • 13.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.15 Check whether all flow status are ADDED - PASS (tick)
  • 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.19 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.20 Check whether all flow status are ADDED - PASS (tick)
  • 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.22 Stopping Mininet - PASS (tick)
  • 13.23 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.13 Check whether all flow status are ADDED - PASS (tick)
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

...

  • 103.1 Apply cell to environment - PASS (tick)
  • 103.2 Uninstalling Atomix - PASS (tick)
  • 103.3 Uninstalling ONOS package - PASS (tick)
  • 103.4 Installing Atomix - PASS (tick)
  • 103.5 Installing ONOS package - PASS (tick)
  • 103.6 Set up ONOS secure SSH - PASS (tick)
  • 103.7 Checking ONOS service - PASS (tick)
  • 103.8 Starting ONOS CLI sessions - PASS (tick)
  • 103.9 Checking ONOS nodes - PASS (tick)
  • 103.10 Checking ONOS applications - PASS (tick)
  • 103.11 Starting Mininet Topology - PASS (tick)
  • 103.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.13 Check whether all flow status are ADDED - PASS (tick)
  • 103.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS (tick)
  • 103.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 103.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 103.17 Check whether the flow count is bigger than 104 - PASS (tick)
  • 103.18 Check whether all flow status are ADDED - PASS (tick)
  • 103.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS (tick)
  • 103.20 Stopping Mininet - PASS (tick)
  • 103.21 Copying karaf logs - PASS (tick)

Case 113: Changing port configuration from tagged 20 and native 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling Atomix - PASS (tick)
  • 113.3 Uninstalling ONOS package - PASS (tick)
  • 113.4 Installing Atomix - PASS (tick)
  • 113.5 Installing ONOS package - PASS (tick)
  • 113.6 Set up ONOS secure SSH - PASS (tick)
  • 113.7 Checking ONOS service - PASS (tick)
  • 113.8 Starting ONOS CLI sessions - PASS (tick)
  • 113.9 Checking ONOS nodes - PASS (tick)
  • 113.10 Checking ONOS applications - PASS (tick)
  • 113.11 Starting Mininet Topology - PASS (tick)
  • 113.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.13 Check whether all flow status are ADDED - PASS (tick)
  • 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.22 Stopping Mininet - PASS (tick)
  • 113.23 Copying karaf logs - PASS (tick)

...