- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Starting Mininet Topology - PASS
- 5.14 Check whether the flow count is bigger than 28 - PASS
- 5.15 Check whether all flow status are ADDED - PASS
- 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS
- 5.18 Stopping Mininet - PASS
- 5.19 Copying karaf logs - PASS
Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR and 3 ONOS instances -
...
FAIL
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Starting Mininet Topology - PASS
- 6.12 Check whether the flow count is bigger than 74 - PASS
- 6.13 Check whether all flow status are ADDED - PASS
- 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS FAIL
- IP connectivity failed
- 6.17 Stopping Mininet - PASS
- 6.18 Copying karaf logs - PASS
...
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Installing Atomix - PASS
- 35.5 Installing ONOS package - PASS
- 35.6 Set up ONOS secure SSH - PASS
- 35.7 Checking ONOS service - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Starting Mininet Topology - PASS
- 35.12 Check whether the flow count is bigger than 28 - PASS
- 35.13 Check whether all flow status are ADDED - PASS
- 35.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 35.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - PASS
- 35.16 Stopping Mininet - PASS
- 35.17 Copying karaf logs - PASS
Case 36: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with dual-homed ToR and 3 ONOS instances -
...
PASS
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Starting Mininet Topology - PASS
- 36.12 Check whether the flow count is bigger than 74 - PASS
- 36.13 Check whether all flow status are ADDED - PASS
- 36.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 36.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 36.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - FAIL
- IP connectivity failed
- PASS
- 36.17 Stopping Mininet - PASS
- 36.18 Copying karaf logs - PASS
...
- 38.1 Apply cell to environment - PASS
- 38.2 Uninstalling Atomix - PASS
- 38.3 Uninstalling ONOS package - PASS
- 38.4 Installing Atomix - PASS
- 38.5 Installing ONOS package - PASS
- 38.6 Set up ONOS secure SSH - PASS
- 38.7 Checking ONOS service - PASS
- 38.8 Starting ONOS CLI sessions - PASS
- 38.9 Checking ONOS nodes - PASS
- 38.10 Checking ONOS applications - PASS
- 38.11 Starting Mininet Topology - PASS
- 38.12 Check whether the flow count is bigger than 212 - PASS
- 38.13 Check whether all flow status are ADDED - PASS
- 38.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 38.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 38.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 38.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 38.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS
- 38.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS
- 38.20 Stopping Mininet - PASS
- 38.21 Copying karaf logs - PASS
Case 45: Bridging test between untagged host and tagged host, with single ToR and 3 ONOS instances -
...
PASS
- 45.1 Apply cell to environment - PASS
- 45.2 Uninstalling Atomix - PASS
- 45.3 Uninstalling ONOS package - PASS
- 45.4 Installing Atomix - PASS
- 45.5 Installing ONOS package - PASS
- 45.6 Set up ONOS secure SSH - PASS
- 45.7 Checking ONOS service - PASS
- 45.8 Starting ONOS CLI sessions - PASS
- 45.9 Checking ONOS nodes - PASS
- 45.10 Checking ONOS applications - PASS
- 45.11 Starting Mininet Topology - PASS
- 45.12 Check whether the flow count is bigger than 28 - PASS
- 45.13 Check whether all flow status are ADDED - PASS
- 45.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 45.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - FAIL IP connectivity failed
- PASS
- 45.16 Stopping Mininet - PASS
- 45.17 Copying karaf logs - PASS
...