Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
HTML |
---|
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRBridging_onos-2.2_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0"> |
commit 70782fc05fab40e77134fdc460f1613394528246 90613fc8b563f96866f390f3c47f857c79344972 (HEAD -] onos-2.2, origin/onos-2.2)
Author: pierventre Jian Li [pier@opennetworkingpyguni@gmail.orgcom]
AuthorDate: Wed Apr 21 12:57:47 2021 +0200Thu Aug 26 22:04:08 2021 +0900
Commit: Pier Luigi Ventre [pier@opennetworking.orgJian Li [pyguni@gmail.com]
CommitDate: Fri Apr 30 04: Thu Aug 26 22:20:33 :23 2021 +0000
[AETHER-1550] Add additional trace logs in P4RT SB0900
Fix: use k8s API config IP address as the controller's IP
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - FAIL
...
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Set logging levels - PASS
- 5.14 Set ONOS configurations - PASS
- 5.15 Starting Mininet Topology - PASS
- 5.16 Check whether the flow count is >= 28 - FAIL
- Flow count looks wrong; found 1718, expecting at least 28
- 5.17 Check whether all flow status are ADDED - PASS
- 5.18 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL
- Flow count looks wrong: 1718
- 5.19 Check number of topology elements - PASS
- 5.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - FAIL
- IP connectivity failed
- 5.21 Stopping Mininet - PASS
- 5.22 Copying karaf logs - PASS
Case 6: Bridging test between two untagged hosts on vlan-untagged port, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
FAIL
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Installing Atomix - PASS
- 6.5 Installing ONOS package - PASS
- 6.6 Set up ONOS secure SSH - PASS
- 6.7 Checking ONOS service - PASS
- 6.8 Starting ONOS CLI sessions - PASS
- 6.9 Checking ONOS nodes - PASS
- 6.10 Checking ONOS applications - PASS
- 6.11 Set logging levels - PASS
- 6.12 Set ONOS configurations - PASS
- 6.13 Starting Mininet Topology - PASS
- 6.14 Check whether the flow count is >= 74 - PASS
- 6.15 Check whether all flow status are ADDED - PASS
- 6.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 6.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS FAIL
- Flow count looks wrong: 17
- 6. 6.18 Check number of topology elements - PASS
- 6.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS FAIL
- IP connectivity failed
- 6.20 Stopping Mininet - PASS
- 6.21 Copying karaf logs - PASS
...
- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Installing Atomix - PASS
- 15.5 Installing ONOS package - PASS
- 15.6 Set up ONOS secure SSH - PASS
- 15.7 Checking ONOS service - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Set logging levels - PASS
- 15.12 Set ONOS configurations - PASS
- 15.13 Starting Mininet Topology - PASS
- 15.14 Check whether the flow count is >= 28 - FAIL
- Flow count looks wrong; found 18, expecting at least 28
- 15.15 Check whether all flow status are ADDED - PASS
- 15.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL
- Flow count looks wrong: 18
- 15.17 Check number of topology elements - PASS
- 15.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - FAIL
- IP connectivity failed
- 15.19 Stopping Mininet - PASS
- 15.20 Copying karaf logs - PASS
Case 16: Bridging test between two tagged hosts, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
PASS
- 16.1 Apply cell to environment - PASS
- 16.2 Uninstalling Atomix - PASS
- 16.3 Uninstalling ONOS package - PASS
- 16.4 Installing Atomix - PASS
- 16.5 Installing ONOS package - PASS
- 16.6 Set up ONOS secure SSH - PASS
- 16.7 Checking ONOS service - PASS
- 16.8 Starting ONOS CLI sessions - PASS
- 16.9 Checking ONOS nodes - PASS
- 16.10 Checking ONOS applications - PASS
- 16.11 Set logging levels - PASS
- 16.12 Set ONOS configurations - PASS
- 16.13 Starting Mininet Topology - PASS
- 16.14 Check whether the flow count is >= 74 - PASS
- 16.15 Check whether all flow status are ADDED - PASS
- 16.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL Flow count looks wrong: 21
- PASS
- 16.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 16.18 Check number of topology elements - PASS
- 16.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - FAIL IP connectivity failed
- PASS
- 16.20 Stopping Mininet - PASS
- 16.21 Copying karaf logs - PASS
...
- 18.1 Apply cell to environment - PASS
- 18.2 Uninstalling Atomix - PASS
- 18.3 Uninstalling ONOS package - PASS
- 18.4 Installing Atomix - PASS
- 18.5 Installing ONOS package - PASS
- 18.6 Set up ONOS secure SSH - PASS
- 18.7 Checking ONOS service - PASS
- 18.8 Starting ONOS CLI sessions - PASS
- 18.9 Checking ONOS nodes - PASS
- 18.10 Checking ONOS applications - PASS
- 18.11 Set logging levels - PASS
- 18.12 Set ONOS configurations - PASS
- 18.13 Starting Mininet Topology - PASS
- 18.14 Check whether the flow count is >= 212 - PASS
- 18.15 Check whether all flow status are ADDED - PASS
- 18.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS
- 18.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS
- 18.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS
- 18.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS
- 18.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 18.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS
- 18.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS
- 18.23 Stopping Mininet - PASS
- 18.24 Copying karaf logs - PASS
Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR, ovs switches and 3 ONOS instances -
...
PASS
- 25.1 Apply cell to environment - PASS
- 25.2 Uninstalling Atomix - PASS
- 25.3 Uninstalling ONOS package - PASS
- 25.4 Installing Atomix - PASS
- 25.5 Installing ONOS package - PASS
- 25.6 Set up ONOS secure SSH - PASS
- 25.7 Checking ONOS service - PASS
- 25.8 Starting ONOS CLI sessions - PASS
- 25.9 Checking ONOS nodes - PASS
- 25.10 Checking ONOS applications - PASS
- 25.11 Set logging levels - PASS
- 25.12 Set ONOS configurations - PASS
- 25.13 Starting Mininet Topology - PASS
- 25.14 Check whether the flow count is >= 28 - FAIL Flow count looks wrong; found 18, expecting at least 28
- PASS
- 25.15 Check whether all flow status are ADDED - PASS
- 25.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL Flow count looks wrong: 18
- PASS
- 25.17 Check number of topology elements - PASS
- 25.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - FAIL IP connectivity failed
- PASS
- 25.19 Stopping Mininet - PASS
- 25.20 Copying karaf logs - PASS
Case 26: Bridging test between two untagged hosts on vlan-native port, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
PASS
- 26.1 Apply cell to environment - PASS
- 26.2 Uninstalling Atomix - PASS
- 26.3 Uninstalling ONOS package - PASS
- 26.4 Installing Atomix - PASS
- 26.5 Installing ONOS package - PASS
- 26.6 Set up ONOS secure SSH - PASS
- 26.7 Checking ONOS service - PASS
- 26.8 Starting ONOS CLI sessions - PASS
- 26.9 Checking ONOS nodes - PASS
- 26.10 Checking ONOS applications - PASS
- 26.11 Set logging levels - PASS
- 26.12 Set ONOS configurations - PASS
- 26.13 Starting Mininet Topology - PASS
- 26.14 Check whether the flow count is >= 74 - FAIL Flow count looks wrong; found 36, expecting at least 74
- PASS
- 26.15 Check whether all flow status are ADDED - PASS
- 26.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL Flow count looks wrong: 18
- PASS
- 26.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL Flow count looks wrong: 18
- PASS
- 26.18 Check number of topology elements - PASS
- 26.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - FAIL IP connectivity failed
- PASS
- 26.20 Stopping Mininet - PASS
- 26.21 Copying karaf logs - PASS
...
- 28.1 Apply cell to environment - PASS
- 28.2 Uninstalling Atomix - PASS
- 28.3 Uninstalling ONOS package - PASS
- 28.4 Installing Atomix - PASS
- 28.5 Installing ONOS package - PASS
- 28.6 Set up ONOS secure SSH - PASS
- 28.7 Checking ONOS service - PASS
- 28.8 Starting ONOS CLI sessions - PASS
- 28.9 Checking ONOS nodes - PASS
- 28.10 Checking ONOS applications - PASS
- 28.11 Set logging levels - PASS
- 28.12 Set ONOS configurations - PASS
- 28.13 Starting Mininet Topology - PASS
- 28.14 Check whether the flow count is >= 212 - PASS FAIL
- Flow count looks wrong; found 108, expecting at least 212
- 28.15 Check whether all flow status are ADDED - PASS
- 28.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 28.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 28.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 28.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 28.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 28.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE28 - PASS FAIL
- IP connectivity failed
- 28.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE28 - PASS FAIL
- IP connectivity failed
- 28.23 Stopping Mininet - PASS
- 28.24 Copying karaf logs - PASS
Case 35: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with single ToR, ovs switches and 3 ONOS instances -
...
PASS
- 35.1 Apply cell to environment - PASS
- 35.2 Uninstalling Atomix - PASS
- 35.3 Uninstalling ONOS package - PASS
- 35.4 Installing Atomix - PASS
- 35.5 Installing ONOS package - PASS
- 35.6 Set up ONOS secure SSH - PASS
- 35.7 Checking ONOS service - PASS
- 35.8 Starting ONOS CLI sessions - PASS
- 35.9 Checking ONOS nodes - PASS
- 35.10 Checking ONOS applications - PASS
- 35.11 Set logging levels - PASS
- 35.12 Set ONOS configurations - PASS
- 35.13 Starting Mininet Topology - PASS
- 35.14 Check whether the flow count is >= 28 - FAIL Flow count looks wrong; found 18, expecting at least 28
- PASS
- 35.15 Check whether all flow status are ADDED - PASS
- 35.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL Flow count looks wrong: 18
- PASS
- 35.17 Check number of topology elements - PASS
- 35.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE35 - FAIL IP connectivity failed
- PASS
- 35.19 Stopping Mininet - PASS
- 35.20 Copying karaf logs - PASS
...
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Set logging levels - PASS
- 36.12 Set ONOS configurations - PASS
- 36.13 Starting Mininet Topology - PASS
- 36.14 Check whether the flow count is >= 74 - PASS
- 36.15 Check whether all flow status are ADDED - PASS
- 36.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 36.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 36.18 Check number of topology elements - PASS
- 36.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS
- 36.20 Stopping Mininet - PASS
- 36.21 Copying karaf logs - PASS
Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -
...
FAIL
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Set logging levels - PASS
- 37.12 Set ONOS configurations - PASS
- 37.13 Starting Mininet Topology - PASS
- 37.14 Check whether the flow count is >= 74 - PASS
- 37.15 Check whether all flow status are ADDED - PASS
- 37.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 37.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 37.18 Check number of topology elements - PASS
- 37.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS FAIL
- IP connectivity failed
- 37.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS
- 37.21 Stopping Mininet - PASS
- 37.22 Copying karaf logs - PASS
...
- 38.1 Apply cell to environment - PASS
- 38.2 Uninstalling Atomix - PASS
- 38.3 Uninstalling ONOS package - PASS
- 38.4 Installing Atomix - PASS
- 38.5 Installing ONOS package - PASS
- 38.6 Set up ONOS secure SSH - PASS
- 38.7 Checking ONOS service - PASS
- 38.8 Starting ONOS CLI sessions - PASS
- 38.9 Checking ONOS nodes - PASS
- 38.10 Checking ONOS applications - PASS
- 38.11 Set logging levels - PASS
- 38.12 Set ONOS configurations - PASS
- 38.13 Starting Mininet Topology - PASS
- 38.14 Check whether the flow count is >= 212 - PASS FAIL
- Flow count looks wrong; found 108, expecting at least 212
- 38.15 Check whether all flow status are ADDED - PASS
- 38.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 38.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 38.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 38.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS FAIL
- Flow count looks wrong: 18
- 38.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 38.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS FAIL
- IP connectivity failed
- 38.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS FAIL
- IP connectivity failed
- 38.23 Stopping Mininet - PASS
- 38.24 Copying karaf logs - PASS
...
- 46.1 Apply cell to environment - PASS
- 46.2 Uninstalling Atomix - PASS
- 46.3 Uninstalling ONOS package - PASS
- 46.4 Installing Atomix - PASS
- 46.5 Installing ONOS package - PASS
- 46.6 Set up ONOS secure SSH - PASS
- 46.7 Checking ONOS service - PASS
- 46.8 Starting ONOS CLI sessions - PASS
- 46.9 Checking ONOS nodes - PASS
- 46.10 Checking ONOS applications - PASS
- 46.11 Set logging levels - PASS
- 46.12 Set ONOS configurations - PASS
- 46.13 Starting Mininet Topology - PASS
- 46.14 Check whether the flow count is >= 74 - FAIL
- Flow count looks wrong; found 3634, expecting at least 74
- 46.15 Check whether all flow status are ADDED - PASS
- 46.16 Check whether the flow count of device of:0000000000000001 >= than 37 - FAIL
- Flow count looks wrong: 1817
- 46.17 Check whether the flow count of device of:0000000000000002 >= than 37 - FAIL
- Flow count looks wrong: 1817
- 46.18 Check number of topology elements - PASS
- 46.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - FAIL
- IP connectivity failed
- 46.20 Stopping Mininet - PASS
- 46.21 Copying karaf logs - PASS
...
- 48.1 Apply cell to environment - PASS
- 48.2 Uninstalling Atomix - PASS
- 48.3 Uninstalling ONOS package - PASS
- 48.4 Installing Atomix - PASS
- 48.5 Installing ONOS package - PASS
- 48.6 Set up ONOS secure SSH - PASS
- 48.7 Checking ONOS service - PASS
- 48.8 Starting ONOS CLI sessions - PASS
- 48.9 Checking ONOS nodes - PASS
- 48.10 Checking ONOS applications - PASS
- 48.11 Set logging levels - PASS
- 48.12 Set ONOS configurations - PASS
- 48.13 Starting Mininet Topology - PASS
- 48.14 Check whether the flow count is >= 212 - FAIL
- Flow count looks wrong; found 108102, expecting at least 212
- 48.15 Check whether all flow status are ADDED - PASS
- 48.16 Check whether the flow count of device of:0000000000000001 >= than 53 - FAIL
- Flow count looks wrong: 1817
- 48.17 Check whether the flow count of device of:0000000000000002 >= than 53 - FAIL
- Flow count looks wrong: 1817
- 48.18 Check whether the flow count of device of:0000000000000003 >= than 53 - FAIL
- Flow count looks wrong: 1817
- 48.19 Check whether the flow count of device of:0000000000000004 >= than 53 - FAIL
- Flow count looks wrong: 1817
- 48.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 48.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - FAIL
- IP connectivity failed
- 48.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - FAIL
- IP connectivity failed
- 48.23 Stopping Mininet - PASS
- 48.24 Copying karaf logs - PASS
Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances -
...
FAIL
- 55.1 Apply cell to environment - PASS
- 55.2 Uninstalling Atomix - PASS
- 55.3 Uninstalling ONOS package - PASS
- 55.4 Installing Atomix - PASS
- 55.5 Installing ONOS package - PASS
- 55.6 Set up ONOS secure SSH - PASS
- 55.7 Checking ONOS service - PASS
- 55.8 Starting ONOS CLI sessions - PASS
- 55.9 Checking ONOS nodes - PASS
- 55.10 Checking ONOS applications - PASS
- 55.11 Set logging levels - PASS
- 55.12 Set ONOS configurations - PASS
- 55.13 Starting Mininet Topology - PASS
- 55.14 Check whether the flow count is >= 28 - PASS FAIL
- Flow count looks wrong; found 18, expecting at least 28
- 55.15 Check whether all flow status are ADDED - PASS
- 55.16 Check whether the flow count of device of:0000000000000001 >= than 28 - PASS FAIL
- Flow count looks wrong: 18
- 55.17 Check number of topology elements - PASS
- 55.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS
- 55.19 Stopping Mininet - PASS
- 55.20 Copying karaf logs - PASS
Case 56: Bridging test between two untagged hosts with different vlan id, with dual-homed ToR, ovs switches and 3 ONOS instances -
...
FAIL
- 56.1 Apply cell to environment - PASS
- 56.2 Uninstalling Atomix - PASS
- 56.3 Uninstalling ONOS package - PASS
- 56.4 Installing Atomix - PASS
- 56.5 Installing ONOS package - PASS
- 56.6 Set up ONOS secure SSH - PASS
- 56.7 Checking ONOS service - PASS
- 56.8 Starting ONOS CLI sessions - PASS
- 56.9 Checking ONOS nodes - PASS
- 56.10 Checking ONOS applications - PASS
- 56.11 Set logging levels - PASS
- 56.12 Set ONOS configurations - PASS
- 56.13 Starting Mininet Topology - PASS
- 56.14 Check whether the flow count is >= 74 - PASS FAIL
- Flow count looks wrong; found 36, expecting at least 74
- 56.15 56.15 Check whether all flow status are ADDED - PASS
- 56.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS FAIL
- Flow count looks wrong: 18
- 56.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS FAIL
- Flow count looks wrong: 18
- 56.18 Check number of topology elements - PASS
- 56.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS
- 56.20 Stopping Mininet - PASS
- 56.21 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances
...
- PASS
- 57.1 Apply cell to environment - PASS
- 57.2 Uninstalling Atomix - PASS
- 57.3 Uninstalling ONOS package - PASS
- 57.4 Installing Atomix - PASS
- 57.5 Installing ONOS package - PASS
- 57.6 Set up ONOS secure SSH - PASS
- 57.7 Checking ONOS service - PASS
- 57.8 Starting ONOS CLI sessions - PASS
- 57.9 Checking ONOS nodes - PASS
- 57.10 Checking ONOS applications - PASS
- 57.11 Set logging levels - PASS
- 57.12 Set ONOS configurations - PASS
- 57.13 Starting Mininet Topology - PASS
- 57.14 Check whether the flow count is >= 74 - PASS
- 57.15 Check whether all flow status are ADDED - PASS
- 57.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 57.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 57.18 Check number of topology elements - PASS
- 57.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS
- 57.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS
- 57.21 Stopping Mininet - PASS
- 57.22 Copying karaf logs - PASS
Case 58: Bridging test between two untagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL
- 58.1 Apply cell to environment - PASS
- 58.2 Uninstalling Atomix - PASS
- 58.3 Uninstalling ONOS package - PASS
- 58.4 Installing Atomix - PASS
- 58.5 Installing ONOS package - PASS
- 58.6 Set up ONOS secure SSH - PASS
- 58.7 Checking ONOS service - PASS
- 58.8 Starting ONOS CLI sessions - PASS
- 58.9 Checking ONOS nodes - PASS
- 58.10 Checking ONOS applications - PASS
- 58.11 Set logging levels - PASS
- 58.12 Set ONOS configurations - PASS
- 58.13 Starting Mininet Topology - PASS
- 58.14 Check whether the flow count is >= 212 - PASS
- 58.15 Check whether all flow status are ADDED - PASS
- 58.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS
- 58.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS
- 58.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS
- 58.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS
- 58.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 58.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS
- 58.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS
- 58.23 Stopping Mininet - PASS
- 58.24 Copying karaf logs - PASS
Case 65: Bridging test between two tagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances - FAIL
- 65.1 Apply cell to environment - PASS
- 65.2 Uninstalling Atomix - PASS
- 65.3 Uninstalling ONOS package - PASS
- 65.4 Installing Atomix - PASS
- 65.5 Installing ONOS package - PASS
- 65.6 Set up ONOS secure SSH - PASS
- 65.7 Checking ONOS service - PASS
- 65.8 Starting ONOS CLI sessions - PASS
- 65.9 Checking ONOS nodes - PASS
- 65.10 Checking ONOS applications - PASS
- 65.11 Set logging levels - PASS
- 65.12 Set ONOS configurations - PASS
- 65.13 Starting Mininet Topology - PASS
- 65.14 Check whether the flow count is >= 28 - FAIL
- Flow count looks wrong; found 17, expecting at least 28
- 65.15 Check whether all flow status are ADDED - PASS
- 65.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL
- Flow count looks wrong: 17
- 65.17 Check number of topology elements - PASS
- 65.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS
- 65.19 Stopping Mininet - PASS
- 65.20 Copying karaf logs - PASS
Case 66: Bridging test between two tagged hosts with different vlan id, with dual-homed ToR, ovs switches and 3 ONOS instances - PASS
- 66.1 Apply cell to environment - PASS
- 66.2 Uninstalling Atomix - PASS
- 66.3 Uninstalling ONOS package - PASS
- 66.4 Installing Atomix - PASS
- 66.5 Installing ONOS package - PASS
- 66.6 Set up ONOS secure SSH - PASS
- 66.7 Checking ONOS service - PASS
- 66.8 Starting ONOS CLI sessions - PASS
- 66.9 Checking ONOS nodes - PASS
- 66.10 Checking ONOS applications - PASS
- 66.11 Set logging levels - PASS
- 66.12 Set ONOS configurations - PASS
- 66.13 Starting Mininet Topology - PASS
- 66.14 Check whether the flow count is >= 74 - PASS
- 66.15 Check whether all flow status are ADDED - PASS
- 66.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 66.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 66.18 Check number of topology elements - PASS
- 66.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS
- 66.20 Stopping Mininet - PASS
- 66.21 Copying karaf logs - PASS
Case 67: Bridging test between two tagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - PASS
- 67.1 Apply cell to environment - PASS
- 67.2 Uninstalling Atomix - PASS
- 67.3 Uninstalling ONOS package - PASS
- 67.4 Installing Atomix - PASS
- 67.5 Installing ONOS package - PASS
- 67.6 Set up ONOS secure SSH - PASS
- 67.7 Checking ONOS service - PASS
- 67.8 Starting ONOS CLI sessions - PASS
- 67.9 Checking ONOS nodes - PASS
- 67.10 Checking ONOS applications - PASS
- 67.11 Set logging levels - PASS
- 67.12 Set ONOS configurations - PASS
- 67.13 Starting Mininet Topology - PASS
- 67.14 Check whether the flow count is >= 74 - PASS
- 67.15 Check whether all flow status are ADDED - PASS
- 67.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 67.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 67.18 Check number of topology elements - PASS
- 67.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE67 - PASS
- 67.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE67 - PASS
- 67.21 Stopping Mininet - PASS
- 67.22 Copying karaf logs - PASS
Case 68: Bridging test between two tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL
- 68.1 Apply cell to environment - PASS
- 68.2 Uninstalling Atomix - PASS
- 68.3 Uninstalling ONOS package - PASS
- 68.4 Installing Atomix - PASS
- 68.5 Installing ONOS package - PASS
- 68.6 Set up ONOS secure SSH - PASS
- 68.7 Checking ONOS service - PASS
- 68.8 Starting ONOS CLI sessions - PASS
- 68.9 Checking ONOS nodes - PASS
- 68.10 Checking ONOS applications - PASS
- 68.11 Set logging levels - PASS
- 68.12 Set ONOS configurations - PASS
- 68.13 Starting Mininet Topology - PASS
- 68.14 Check whether the flow count is >= 212 - PASS
- 68.15 Check whether all flow status are ADDED - PASS
- 68.16 Check whether the flow count of device of:0000000000000001 >= than 53 - FAIL
- Flow count looks wrong: 21
- 68.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS
- 68.18 Check whether the flow count of device of:0000000000000003 >= than 53 - FAIL
- Flow count looks wrong: 18
- 68.19 Check whether the flow count of device of:0000000000000004 >= than 53 - FAIL
- Flow count looks wrong: 18
- 68.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 68.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE68 - PASS
- 68.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE68 - PASS
- 68.23 Stopping Mininet - PASS
- 68.24 Copying karaf logs - PASS
Case 75: Bridging test between untagged and tagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances - FAIL
- 75.1 Apply cell to environment - PASS
- 75.2 Uninstalling Atomix - PASS
- 75.3 Uninstalling ONOS package - PASS
- 75.4 Installing Atomix - PASS
- 75.5 Installing ONOS package - PASS
- 75.6 Set up ONOS secure SSH - PASS
- 75.7 Checking ONOS service - PASS
- 75.8 Starting ONOS CLI sessions - PASS
- 75.9 Checking ONOS nodes - PASS
- 75.10 Checking ONOS applications - PASS
- 75.11 Set logging levels - PASS
- 75.12 Set ONOS configurations - PASS
- 75.13 Starting Mininet Topology - PASS
- 75.14 Check whether the flow count is >= 28 - FAIL
- Flow count looks wrong; found 18, expecting at least 28
- 75.15 Check whether all flow status are ADDED - PASS
- 75.16 Check whether the flow count of device of:0000000000000001 >= than 28 - FAIL
- Flow count looks wrong: 18
- 75.17 Check number of topology elements - PASS
- 75.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE75 - PASS
- 75.19 Stopping Mininet - PASS
- 75.20 Copying karaf logs - PASS
Case 76: Bridging test between untagged and tagged hosts with different vlan id, with dual-homed ToR, ovs switches and 3 ONOS instances - PASS
- 76.1 Apply cell to environment - PASS
- 76.2 Uninstalling Atomix - PASS
- 76.3 Uninstalling ONOS package - PASS
- 76.4 Installing Atomix - PASS
- 76.5 Installing ONOS package - PASS
- 76.6 Set up ONOS secure SSH - PASS
- 76.7 Checking ONOS service - PASS
- 76.8 Starting ONOS CLI sessions - PASS
- 76.9 Checking ONOS nodes - PASS
- 76.10 Checking ONOS applications - PASS
- 76.11 Set logging levels - PASS
- 76.12 Set ONOS configurations - PASS
- 76.13 Starting Mininet Topology - PASS
- 76.14 Check whether the flow count is >= 74 - PASS
- 76.15 Check whether all flow status are ADDED - PASS
- 76.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 76.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 76.18 Check number of topology elements - PASS
- 76.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE76 - PASS
- 76.20 Stopping Mininet - PASS
- 76.21 Copying karaf logs - PASS
Case 77: Bridging test between untagged and tagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - PASS
- 77.1 Apply cell to environment - PASS
- 77.2 Uninstalling Atomix - PASS
- 77.3 Uninstalling ONOS package - PASS
- 77.4 Installing Atomix - PASS
- 77.5 Installing ONOS package - PASS
- 77.6 Set up ONOS secure SSH - PASS
- 77.7 Checking ONOS service - PASS
- 77.8 Starting ONOS CLI sessions - PASS
- 77.9 Checking ONOS nodes - PASS
- 77.10 Checking ONOS applications - PASS
- 77.11 Set logging levels - PASS
- 77.12 Set ONOS configurations - PASS
- 77.13 Starting Mininet Topology - PASS
- 77.14 Check whether the flow count is >= 74 - PASS
- 77.15 Check whether all flow status are ADDED - PASS
- 77.16 Check whether the flow count of device of:0000000000000001 >= than 37 - PASS
- 77.17 Check whether the flow count of device of:0000000000000002 >= than 37 - PASS
- 77.18 Check number of topology elements - PASS
- 77.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS
- 77.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS
- 77.21 Stopping Mininet - PASS
- 77.22 Copying karaf logs - PASS
Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances - FAIL
- 78.1 Apply cell to environment - PASS
- 78.2 Uninstalling Atomix - PASS
- 78.3 Uninstalling ONOS package - PASS
- 78.4 Installing Atomix - PASS
- 78.5 Installing ONOS package - PASS
- 78.6 Set up ONOS secure SSH - PASS
- 78.7 Checking ONOS service - PASS
- 78.8 Starting ONOS CLI sessions - PASS
- 78.9 Checking ONOS nodes - PASS
- 78.10 Checking ONOS applications - PASS
- 78.11 Set logging levels - PASS
- 78.12 Set ONOS configurations - PASS
- 78.13 Starting Mininet Topology - PASS
- 78.14 Check whether the flow count is >= 212 - PASS
- 78.15 Check whether all flow status are ADDED - PASS
- 78.16 Check whether the flow count of device of:0000000000000001 >= than 53 - PASS
- 78.17 Check whether the flow count of device of:0000000000000002 >= than 53 - PASS
- 78.18 Check whether the flow count of device of:0000000000000003 >= than 53 - PASS
- 78.19 Check whether the flow count of device of:0000000000000004 >= than 53 - PASS
- 78.20 Check number of topology elements - FAIL
- Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
- ONOS sees 6 devices (6 expected) and 36 links (38 expected) and 3 controllers (3 expected) and 1 SCCs (1 expected)
- 78.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS
- 78.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS
- 78.23 Stopping Mininet - PASS
- 78.24 Copying karaf logs - PASS
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - FAIL
Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances - FAIL
...