  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Set logging levels - PASS (tick)
  • 7.12 Set ONOS configurations - PASS (tick)
  • 7.13 Starting Mininet Topology - PASS (tick)
  • 7.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.15 Check whether all flow status are ADDED - PASS (tick)
  • 7.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 7.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 7.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS (tick)
  • 7.20 Stopping Mininet - PASS (tick)
  • 7.21 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Set logging levels - PASS (tick)
  • 8.12 Set ONOS configurations - PASS (tick)
  • 8.13 Starting Mininet Topology - PASS (tick)
  • 8.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.15 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • PASS (tick)
  • 8.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 25
  • PASS (tick)
  • 8.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 8.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 8.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 8.22 Stopping Mininet - PASS (tick)
  • 8.23 Copying karaf logs - PASS (tick)

...

  • 16.1 Apply cell to environment - PASS (tick)
  • 16.2 Uninstalling Atomix - PASS (tick)
  • 16.3 Uninstalling ONOS package - PASS (tick)
  • 16.4 Installing Atomix - PASS (tick)
  • 16.5 Installing ONOS package - PASS (tick)
  • 16.6 Set up ONOS secure SSH - PASS (tick)
  • 16.7 Checking ONOS service - PASS (tick)
  • 16.8 Starting ONOS CLI sessions - PASS (tick)
  • 16.9 Checking ONOS nodes - PASS (tick)
  • 16.10 Checking ONOS applications - PASS (tick)
  • 16.11 Set logging levels - PASS (tick)
  • 16.12 Set ONOS configurations - PASS (tick)
  • 16.13 Starting Mininet Topology - PASS (tick)
  • 16.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 16.15 Check whether all flow status are ADDED - PASS (tick)
  • 16.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 16.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 16.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE16 - PASS (tick)
  • 16.19 Stopping Mininet - PASS (tick)
  • 16.20 Copying karaf logs - PASS (tick)

Case 17: Bridging test between two tagged hosts, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Set logging levels - PASS (tick)
  • 17.12 Set ONOS configurations - PASS (tick)
  • 17.13 Starting Mininet Topology - PASS (tick)
  • 17.14 Check whether the flow count is bigger than 74 - FAIL (error)
  • Flow count looks wrong; found 68, expecting at least 74
  • PASS (tick)
  • 17.15 Check whether all flow status are ADDED - PASS (tick)
  • 17.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 17
  • PASS (tick)
  • 17.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 17
  • PASS (tick)
  • 17.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 17.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 17.20 Stopping Mininet - PASS (tick)
  • 17.21 Copying karaf logs - PASS (tick)

Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Set logging levels - PASS (tick)
  • 18.12 Set ONOS configurations - PASS (tick)
  • 18.13 Starting Mininet Topology - PASS (tick)
  • 18.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 18.15 Check whether all flow status are ADDED - PASS (tick)
  • 18.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 18.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 18.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 18.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 20
  • 18.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)CASE18 - FAIL (error)
    • IP connectivity failed
  • 18.22 Stopping Mininet - PASS (tick)
  • 18.23 Copying karaf logs - PASS (tick)

...

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Set logging levels - PASS (tick)
  • 37.12 Set ONOS configurations - PASS (tick)
  • 37.13 Starting Mininet Topology - PASS (tick)
  • 37.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.15 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 37.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 25
  • 37.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 37.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 37.20 Stopping Mininet - PASS (tick)
  • 37.21 Copying karaf logs - PASS (tick)

...

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling Atomix - PASS (tick)
  • 48.3 Uninstalling ONOS package - PASS (tick)
  • 48.4 Installing Atomix - PASS (tick)
  • 48.5 Installing ONOS package - PASS (tick)
  • 48.6 Set up ONOS secure SSH - PASS (tick)
  • 48.7 Checking ONOS service - PASS (tick)
  • 48.8 Starting ONOS CLI sessions - PASS (tick)
  • 48.9 Checking ONOS nodes - PASS (tick)
  • 48.10 Checking ONOS applications - PASS (tick)
  • 48.11 Set logging levels - PASS (tick)
  • 48.12 Set ONOS configurations - PASS (tick)
  • 48.13 Starting Mininet Topology - PASS (tick)
  • 48.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 48.15 Check whether all flow status are ADDED - PASS (tick)
  • 48.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 48.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 48.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 48.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 48.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS (tick)
  • 48.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS (tick)
  • 48.22 Stopping Mininet - PASS (tick)
  • 48.23 Copying karaf logs - PASS (tick)

Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 55.1 Apply cell to environment - PASS (tick)
  • 55.2 Uninstalling Atomix - PASS (tick)
  • 55.3 Uninstalling ONOS package - PASS (tick)
  • 55.4 Installing Atomix - PASS (tick)
  • 55.5 Installing ONOS package - PASS (tick)
  • 55.6 Set up ONOS secure SSH - PASS (tick)
  • 55.7 Checking ONOS service - PASS (tick)
  • 55.8 Starting ONOS CLI sessions - PASS (tick)
  • 55.9 Checking ONOS nodes - PASS (tick)
  • 55.10 Checking ONOS applications - PASS (tick)
  • 55.11 Set logging levels - PASS (tick)
  • 55.12 Set ONOS configurations - PASS (tick)
  • 55.13 Starting Mininet Topology - PASS (tick)
  • 55.14 Check whether the flow count is bigger than 28 - FAIL (error)
    • Flow count looks wrong; found 17, expecting at least 28
  • PASS (tick)
  • 55.15 Check whether all flow status are ADDED - PASS (tick)
  • 55.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
  • Flow count looks wrong: 17
  • PASS (tick)
  • 55.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS (tick)
  • 55.18 Stopping Mininet - PASS (tick)
  • 55.19 Copying karaf logs - PASS (tick)

...

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Set logging levels - PASS (tick)
  • 77.12 Set ONOS configurations - PASS (tick)
  • 77.13 Starting Mininet Topology - PASS (tick)
  • 77.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.15 Check whether all flow status are ADDED - PASS (tick)
  • 77.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 77.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.20 Stopping Mininet - PASS (tick)
  • 77.21 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling Atomix - PASS (tick)
  • 78.3 Uninstalling ONOS package - PASS (tick)
  • 78.4 Installing Atomix - PASS (tick)
  • 78.5 Installing ONOS package - PASS (tick)
  • 78.6 Set up ONOS secure SSH - PASS (tick)
  • 78.7 Checking ONOS service - PASS (tick)
  • 78.8 Starting ONOS CLI sessions - PASS (tick)
  • 78.9 Checking ONOS nodes - PASS (tick)
  • 78.10 Checking ONOS applications - PASS (tick)
  • 78.11 Set logging levels - PASS (tick)
  • 78.12 Set ONOS configurations - PASS (tick)
  • 78.13 Starting Mininet Topology - PASS (tick)
  • 78.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 78.15 Check whether all flow status are ADDED - PASS (tick)
  • 78.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 78.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 78.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 78.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 78.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.22 Stopping Mininet - PASS (tick)
  • 78.23 Copying karaf logs - PASS (tick)