Lowering error log for optional TLV type in LLDP packet0900

Refactor: remove verbose logging message at openstack networking

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Starting Mininet Topology - PASS (tick)
  • 13.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.15 Check whether all flow status are ADDED - PASS (tick)
  • 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.19 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.20 Check whether all flow status are ADDED - PASS (tick)
  • 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.22 Stopping Mininet - PASS (tick)
  • 13.23 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.13 Check whether all flow status are ADDED - PASS (tick)
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling Atomix - PASS (tick)
  • 33.3 Uninstalling ONOS package - PASS (tick)
  • 33.4 Installing Atomix - PASS (tick)
  • 33.5 Installing ONOS package - PASS (tick)
  • 33.6 Set up ONOS secure SSH - PASS (tick)
  • 33.7 Checking ONOS service - PASS (tick)
  • 33.8 Starting ONOS CLI sessions - PASS (tick)
  • 33.9 Checking ONOS nodes - PASS (tick)
  • 33.10 Checking ONOS applications - PASS (tick)
  • 33.11 Starting Mininet Topology - PASS (tick)
  • 33.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.13 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong: 21
  • PASS (tick)
  • 33.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.22 Stopping Mininet - PASS (tick)
  • 33.23 Copying karaf logs - PASS (tick)

...

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling Atomix - PASS (tick)
  • 83.3 Uninstalling ONOS package - PASS (tick)
  • 83.4 Installing Atomix - PASS (tick)
  • 83.5 Installing ONOS package - PASS (tick)
  • 83.6 Set up ONOS secure SSH - PASS (tick)
  • 83.7 Checking ONOS service - PASS (tick)
  • 83.8 Starting ONOS CLI sessions - PASS (tick)
  • 83.9 Checking ONOS nodes - PASS (tick)
  • 83.10 Checking ONOS applications - PASS (tick)
  • 83.11 Starting Mininet Topology - PASS (tick)
  • 83.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.13 Check whether all flow status are ADDED - PASS (tick)
  • 83.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - PASS (tick)
  • 83.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 83.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 83.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.19 Check whether all flow status are ADDED - PASS (tick)
  • 83.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - PASS (tick)
  • 83.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - PASS (tick)
  • 83.22 Stopping Mininet - PASS (tick)
  • 83.23 Copying karaf logs - PASS (tick)

Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling Atomix - PASS (tick)
  • 93.3 Uninstalling ONOS package - PASS (tick)
  • 93.4 Installing Atomix - PASS (tick)
  • 93.5 Installing ONOS package - PASS (tick)
  • 93.6 Set up ONOS secure SSH - PASS (tick)
  • 93.7 Checking ONOS service - PASS (tick)
  • 93.8 Starting ONOS CLI sessions - PASS (tick)
  • 93.9 Checking ONOS nodes - PASS (tick)
  • 93.10 Checking ONOS applications - PASS (tick)
  • 93.11 Starting Mininet Topology - PASS (tick)
  • 93.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.13 Check whether all flow status are ADDED - PASS (tick)
  • 93.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 93.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)
  • 93.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 93.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 93.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.19 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 93.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 93.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)
  • 93.22 Stopping Mininet - PASS (tick)
  • 93.23 Copying karaf logs - PASS (tick)

...

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling Atomix - PASS (tick)
  • 113.3 Uninstalling ONOS package - PASS (tick)
  • 113.4 Installing Atomix - PASS (tick)
  • 113.5 Installing ONOS package - PASS (tick)
  • 113.6 Set up ONOS secure SSH - PASS (tick)
  • 113.7 Checking ONOS service - PASS (tick)
  • 113.8 Starting ONOS CLI sessions - PASS (tick)
  • 113.9 Checking ONOS nodes - PASS (tick)
  • 113.10 Checking ONOS applications - PASS (tick)
  • 113.11 Starting Mininet Topology - PASS (tick)
  • 113.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.13 Check whether all flow status are ADDED - PASS (tick)
  • 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.19 Check whether all flow status are ADDED - PASS (tick)
  • 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.22 Stopping Mininet - PASS (tick)
  • 113.23 Copying karaf logs - PASS (tick)

Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling Atomix - PASS (tick)
  • 123.3 Uninstalling ONOS package - PASS (tick)
  • 123.4 Installing Atomix - PASS (tick)
  • 123.5 Installing ONOS package - PASS (tick)
  • 123.6 Set up ONOS secure SSH - PASS (tick)
  • 123.7 Checking ONOS service - PASS (tick)
  • 123.8 Starting ONOS CLI sessions - PASS (tick)
  • 123.9 Checking ONOS nodes - PASS (tick)
  • 123.10 Checking ONOS applications - PASS (tick)
  • 123.11 Starting Mininet Topology - PASS (tick)
  • 123.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.13 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 25
  • 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 123.22 Stopping Mininet - PASS (tick)
  • 123.23 Copying karaf logs - PASS (tick)

...

  • 173.1 Apply cell to environment - PASS (tick)
  • 173.2 Uninstalling Atomix - PASS (tick)
  • 173.3 Uninstalling ONOS package - PASS (tick)
  • 173.4 Installing Atomix - PASS (tick)
  • 173.5 Installing ONOS package - PASS (tick)
  • 173.6 Set up ONOS secure SSH - PASS (tick)
  • 173.7 Checking ONOS service - PASS (tick)
  • 173.8 Starting ONOS CLI sessions - PASS (tick)
  • 173.9 Checking ONOS nodes - PASS (tick)
  • 173.10 Checking ONOS applications - PASS (tick)
  • 173.11 Starting Mininet Topology - PASS (tick)
  • 173.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.13 Check whether all flow status are ADDED - PASS (tick)
  • 173.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - PASS (tick)
  • 173.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS (tick)
  • 173.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 173.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 173.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 173.19 Check whether all flow status are ADDED - PASS (tick)
  • 173.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - PASS (tick)
  • 173.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS (tick)
  • 173.22 Stopping Mininet - PASS (tick)
  • 173.23 Copying karaf logs - PASS (tick)

Case 183: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 183.1 Apply cell to environment - PASS (tick)
  • 183.2 Uninstalling Atomix - PASS (tick)
  • 183.3 Uninstalling ONOS package - PASS (tick)
  • 183.4 Installing Atomix - PASS (tick)
  • 183.5 Installing ONOS package - PASS (tick)
  • 183.6 Set up ONOS secure SSH - PASS (tick)
  • 183.7 Checking ONOS service - PASS (tick)
  • 183.8 Starting ONOS CLI sessions - PASS (tick)
  • 183.9 Checking ONOS nodes - PASS (tick)
  • 183.10 Checking ONOS applications - PASS (tick)
  • 183.11 Starting Mininet Topology - PASS (tick)
  • 183.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.13 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 183.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS (tick)
  • 183.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS (tick)
  • 183.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 183.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 183.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 183.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS (tick)
  • 183.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS (tick)
  • 183.22 Stopping Mininet - PASS (tick)
  • 183.23 Copying karaf logs - PASS (tick)

...