Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Installing Atomix - PASS
- 63.5 Installing ONOS package - PASS
- 63.6 Set up ONOS secure SSH - PASS
- 63.7 Checking ONOS service - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Set logging levels - PASS
- 63.12 Set ONOS configurations - PASS
- 63.13 Starting Mininet Topology - PASS
- 63.14 Check whether the flow count is bigger than 104 - PASS
- 63.15 Check whether all flow status are ADDED - PASS
- 63.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.20 Check whether the flow count is bigger than 104 - PASS
- 63.21 Check whether all flow status are ADDED - PASS
- 63.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.24 Stopping Mininet - PASS
- 63.25 Copying karaf logs - PASS
Case 73: Changing port configuration from tagged 10 to untagged 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 73.1 Apply cell to environment - PASS
- 73.2 Uninstalling Atomix - PASS
- 73.3 Uninstalling ONOS package - PASS
- 73.4 Installing Atomix - PASS
- 73.5 Installing ONOS package - PASS
- 73.6 Set up ONOS secure SSH - PASS
- 73.7 Checking ONOS service - PASS
- 73.8 Starting ONOS CLI sessions - PASS
- 73.9 Checking ONOS nodes - PASS
- 73.10 Checking ONOS applications - PASS
- 73.11 Set logging levels - PASS
- 73.12 Set ONOS configurations - PASS
- 73.13 Starting Mininet Topology - PASS
- 73.14 Check whether the flow count is bigger than 106 - PASS
- 73.15 Check whether all flow status are ADDED - PASS
- 73.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_Before - FAIL IP connectivity failed
- PASS
- 73.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_Before - FAIL IP connectivity failed
- PASS
- 73.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 73.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 73.20 Check whether the flow count is bigger than 106 - PASS
- 73.21 Check whether all flow status are ADDED - PASS
- 73.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE73_After - FAIL IP connectivity failed
- PASS
- 73.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE73_After - FAIL IP connectivity failed
- PASS
- 73.24 Stopping Mininet - PASS
- 73.25 Copying karaf logs - PASS
Case 83: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 83.1 Apply cell to environment - PASS
- 83.2 Uninstalling Atomix - PASS
- 83.3 Uninstalling ONOS package - PASS
- 83.4 Installing Atomix - PASS
- 83.5 Installing ONOS package - PASS
- 83.6 Set up ONOS secure SSH - PASS
- 83.7 Checking ONOS service - PASS
- 83.8 Starting ONOS CLI sessions - PASS
- 83.9 Checking ONOS nodes - PASS
- 83.10 Checking ONOS applications - PASS
- 83.11 Set logging levels - PASS
- 83.12 Set ONOS configurations - PASS
- 83.13 Starting Mininet Topology - PASS
- 83.14 Check whether the flow count is bigger than 104 - PASS
- 83.15 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- PASS
- 83.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - FAIL
- IP connectivity failed
- PASS
- 83.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS
- 83.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL Flow count looks wrong: 22
- PASS
- 83.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 83.20 Check whether the flow count is bigger than 104 - PASS
- 83.21 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- PASS
- 83.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - FAIL
- IP connectivity failed
- PASS
- 83.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - FAIL IP connectivity failed
- PASS
- 83.24 Stopping Mininet - PASS
- 83.25 Copying karaf logs - PASS
Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 93.1 Apply cell to environment - PASS
- 93.2 Uninstalling Atomix - PASS
- 93.3 Uninstalling ONOS package - PASS
- 93.4 Installing Atomix - PASS
- 93.5 Installing ONOS package - PASS
- 93.6 Set up ONOS secure SSH - PASS
- 93.7 Checking ONOS service - PASS
- 93.8 Starting ONOS CLI sessions - PASS
- 93.9 Checking ONOS nodes - PASS
- 93.10 Checking ONOS applications - PASS
- 93.11 Set logging levels - PASS
- 93.12 Set ONOS configurations - PASS
- 93.13 Starting Mininet Topology - PASS
- 93.14 Check whether the flow count is bigger than 106 - PASS
- 93.15 Check whether all flow status are ADDED - PASS
- 93.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS FAIL
- IP connectivity failed
- 93.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS FAIL
- IP connectivity failed
- 93.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 93.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 93.20 Check whether the flow count is bigger than 106 - PASS
- 93.21 Check whether all flow status are ADDED - PASS
- 93.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS FAIL
- IP connectivity failed
- 93.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS
- 93.24 Stopping Mininet - PASS
- 93.25 Copying karaf logs - PASS
Case 103: Changing port configuration from tagged 10 and native 20 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 103.1 Apply cell to environment - PASS
- 103.2 Uninstalling Atomix - PASS
- 103.3 Uninstalling ONOS package - PASS
- 103.4 Installing Atomix - PASS
- 103.5 Installing ONOS package - PASS
- 103.6 Set up ONOS secure SSH - PASS
- 103.7 Checking ONOS service - PASS
- 103.8 Starting ONOS CLI sessions - PASS
- 103.9 Checking ONOS nodes - PASS
- 103.10 Checking ONOS applications - PASS
- 103.11 Set logging levels - PASS
- 103.12 Set ONOS configurations - PASS
- 103.13 Starting Mininet Topology - PASS
- 103.14 Check whether the flow count is bigger than 104 - PASS
- 103.15 Check whether all flow status are ADDED - PASS
- 103.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_Before - PASS FAIL
- IP connectivity failed
- 103.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 103.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 103.19 Check whether the flow count is bigger than 104 - PASS
- 103.20 Check whether all flow status are ADDED - PASS
- 103.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE103_After - PASS FAIL
- IP connectivity failed
- 103.22 Stopping Mininet - PASS
- 103.23 Copying karaf logs - PASS
...
- 113.1 Apply cell to environment - PASS
- 113.2 Uninstalling Atomix - PASS
- 113.3 Uninstalling ONOS package - PASS
- 113.4 Installing Atomix - PASS
- 113.5 Installing ONOS package - PASS
- 113.6 Set up ONOS secure SSH - PASS
- 113.7 Checking ONOS service - PASS
- 113.8 Starting ONOS CLI sessions - PASS
- 113.9 Checking ONOS nodes - PASS
- 113.10 Checking ONOS applications - PASS
- 113.11 Set logging levels - PASS
- 113.12 Set ONOS configurations - PASS
- 113.13 Starting Mininet Topology - PASS
- 113.14 Check whether the flow count is bigger than 104 - PASS
- 113.15 Check whether all flow status are ADDED - PASS
- 113.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS
- 113.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS
- 113.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 113.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 113.20 Check whether the flow count is bigger than 104 - PASS
- 113.21 Check whether all flow status are ADDED - PASS
- 113.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS
- 113.23 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS
- 113.24 Stopping Mininet - PASS
- 113.25 Copying karaf logs - PASS
Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 123.1 Apply cell to environment - PASS
- 123.2 Uninstalling Atomix - PASS
- 123.3 Uninstalling ONOS package - PASS
- 123.4 Installing Atomix - PASS
- 123.5 Installing ONOS package - PASS
- 123.6 Set up ONOS secure SSH - PASS
- 123.7 Checking ONOS service - PASS
- 123.8 Starting ONOS CLI sessions - PASS
- 123.9 Checking ONOS nodes - PASS
- 123.10 Checking ONOS applications - PASS
- 123.11 Set logging levels - PASS
- 123.12 Set ONOS configurations - PASS
- 123.13 Starting Mininet Topology - PASS
- 123.14 Check whether the flow count is bigger than 104 - PASS
- 123.15 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 123.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS
- 123.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS
- 123.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 123.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 123.20 Check whether the flow count is bigger than 104 - PASS
- 123.21 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- status are ADDED - PASS
- 123.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS
- 123.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS
- 123.24 Stopping Mininet - PASS
- 123.25 Copying karaf logs - PASS
...
- 163.1 Apply cell to environment - PASS
- 163.2 Uninstalling Atomix - PASS
- 163.3 Uninstalling ONOS package - PASS
- 163.4 Installing Atomix - PASS
- 163.5 Installing ONOS package - PASS
- 163.6 Set up ONOS secure SSH - PASS
- 163.7 Checking ONOS service - PASS
- 163.8 Starting ONOS CLI sessions - PASS
- 163.9 Checking ONOS nodes - PASS
- 163.10 Checking ONOS applications - PASS
- 163.11 Set logging levels - PASS
- 163.12 Set ONOS configurations - PASS
- 163.13 Starting Mininet Topology - PASS
- 163.14 Check whether the flow count is bigger than 106 - PASS
- 163.15 Check whether all flow status are ADDED - PASS
- 163.16 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS
- 163.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS
- 163.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 163.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 163.20 Check whether the flow count is bigger than 106 - PASS
- 163.21 Check whether all flow status are ADDED - PASS
- 163.22 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS
- 163.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS
- 163.24 Stopping Mininet - PASS
- 163.25 Copying karaf logs - PASS
Case 173: Changing port configuration from tagged 20 to tagged 120, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 173.1 Apply cell to environment - PASS
- 173.2 Uninstalling Atomix - PASS
- 173.3 Uninstalling ONOS package - PASS
- 173.4 Installing Atomix - PASS
- 173.5 Installing ONOS package - PASS
- 173.6 Set up ONOS secure SSH - PASS
- 173.7 Checking ONOS service - PASS
- 173.8 Starting ONOS CLI sessions - PASS
- 173.9 Checking ONOS nodes - PASS
- 173.10 Checking ONOS applications - PASS
- 173.11 Set logging levels - PASS
- 173.12 Set ONOS configurations - PASS
- 173.13 Starting Mininet Topology - PASS
- 173.14 Check whether the flow count is bigger than 106 - PASS
- 173.15 Check whether all flow status are ADDED - PASS
- 173.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE173_Before - FAIL
- IP connectivity failed
- PASS
- 173.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE173_Before - PASS
- 173.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 173.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 173.20 Check whether the flow count is bigger than 106 - PASS
- 173.21 Check whether all flow status are ADDED - PASS
- 173.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE173_After - FAIL IP connectivity failed
- PASS
- 173.23 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE173_After - PASS
- 173.24 Stopping Mininet - PASS
- 173.25 Copying karaf logs - PASS
Case 183: Changing port configuration from tagged 20 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 183.1 Apply cell to environment - PASS
- 183.2 Uninstalling Atomix - PASS
- 183.3 Uninstalling ONOS package - PASS
- 183.4 Installing Atomix - PASS
- 183.5 Installing ONOS package - PASS
- 183.6 Set up ONOS secure SSH - PASS
- 183.7 Checking ONOS service - PASS
- 183.8 Starting ONOS CLI sessions - PASS
- 183.9 Checking ONOS nodes - PASS
- 183.10 Checking ONOS applications - PASS
- 183.11 Set logging levels - PASS
- 183.12 Set ONOS configurations - PASS
- 183.13 Starting Mininet Topology - PASS
- 183.14 Check whether the flow count is bigger than 106 - PASS
- 183.15 Check whether all flow status are ADDED - PASS
- 183.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS FAIL
- IP connectivity failed
- 183.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS
- 183.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 183.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 183.20 Check whether the flow count is bigger than 106 - PASS
- 183.21 Check whether all flow status are ADDED - PASS
- 183.22 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS FAIL
- IP connectivity failed
- 183.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS
- 183.24 Stopping Mininet - PASS
- 183.25 Copying karaf logs - PASS
...
- 213.1 Apply cell to environment - PASS
- 213.2 Uninstalling Atomix - PASS
- 213.3 Uninstalling ONOS package - PASS
- 213.4 Installing Atomix - PASS
- 213.5 Installing ONOS package - PASS
- 213.6 Set up ONOS secure SSH - PASS
- 213.7 Checking ONOS service - PASS
- 213.8 Starting ONOS CLI sessions - PASS
- 213.9 Checking ONOS nodes - PASS
- 213.10 Checking ONOS applications - PASS
- 213.11 Set logging levels - PASS
- 213.12 Set ONOS configurations - PASS
- 213.13 Starting Mininet Topology - PASS
- 213.14 Check whether the flow count is bigger than 106 - PASS
- 213.15 Check whether all flow status are ADDED - PASS
- 213.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS
- 213.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS
- 213.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 213.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 213.20 Check whether the flow count is bigger than 106 - PASS
- 213.21 Check whether all flow status are ADDED - PASS
- 213.22 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS
- 213.23 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS
- 213.24 Stopping Mininet - PASS
- 213.25 Copying karaf logs - PASS
Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 223.1 Apply cell to environment - PASS
- 223.2 Uninstalling Atomix - PASS
- 223.3 Uninstalling ONOS package - PASS
- 223.4 Installing Atomix - PASS
- 223.5 Installing ONOS package - PASS
- 223.6 Set up ONOS secure SSH - PASS
- 223.7 Checking ONOS service - PASS
- 223.8 Starting ONOS CLI sessions - PASS
- 223.9 Checking ONOS nodes - PASS
- 223.10 Checking ONOS applications - PASS
- 223.11 Set logging levels - PASS
- 223.12 Set ONOS configurations - PASS
- 223.13 Starting Mininet Topology - PASS
- 223.14 Check whether the flow count is bigger than 106 - PASS
- 223.15 Check whether all flow status are ADDED - PASS
- 223.16 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - FAIL
- IP connectivity failed
- PASS
- 223.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS
- 223.18 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 223.19 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 223.20 Check whether the flow count is bigger than 106 - PASS
- 223.21 Check whether all flow status are ADDED - PASS
- 223.22 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - FAIL
- IP connectivity failed
- PASS
- 223.23 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS
- 223.24 Stopping Mininet - PASS
- 223.25 Copying karaf logs - PASS
...
- 243.1 Apply cell to environment - PASS
- 243.2 Uninstalling Atomix - PASS
- 243.3 Uninstalling ONOS package - PASS
- 243.4 Installing Atomix - PASS
- 243.5 Installing ONOS package - PASS
- 243.6 Set up ONOS secure SSH - PASS
- 243.7 Checking ONOS service - PASS
- 243.8 Starting ONOS CLI sessions - PASS
- 243.9 Checking ONOS nodes - PASS
- 243.10 Checking ONOS applications - PASS
- 243.11 Set logging levels - PASS
- 243.12 Set ONOS configurations - PASS
- 243.13 Starting Mininet Topology - PASS
- 243.14 Check whether the flow count is bigger than 104 - PASS
- 243.15 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 243.16 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_Before - FAIL IP connectivity failed
- PASS
- 243.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- Flow count looks wrong: 23
- PASS
- 243.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 243.19 Check whether the flow count is bigger than 104 - PASS
- 243.20 Check whether all flow status are ADDED - FAIL Flow status is wrong!
- PASS
- 243.21 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_After - FAIL
- IP connectivity failed
- 243.22 Stopping Mininet - PASS
- 243.23 Copying karaf logs - PASS