Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.2/3/

...

commit 35a35c52a9d7b2d4e9d27a861a4f33e48e081285 (HEAD -] onos-2.2, origin/onos-2.2)
Author: ONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Fri Aug 30 20:11:47 2019 +0000
Commit: ONOS Jenkins User [jenkins@onlab.us]
CommitDate: Fri Aug 30 20:11:47 2019 +0000

Starting snapshot 2.2.1-SNAPSHOT

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -

...

PASS

  • 5.1 Constructing test variables - PASS (tick)
  • 5.2 Apply cell to environment - PASS (tick)
  • 5.3 Uninstalling Atomix - PASS (tick)
  • 5.4 Uninstalling ONOS package - PASS (tick)
  • 5.5 Creating ONOS package - PASS (tick)
  • 5.6 Installing Atomix - PASS (tick)
  • 5.7 Installing ONOS package - PASS (tick)
  • 5.8 Set up ONOS secure SSH - PASS (tick)
  • 5.9 Checking ONOS service - PASS (tick)
  • 5.10 Starting ONOS CLI sessions - PASS (tick)
  • 5.11 Checking ONOS nodes - PASS (tick)
  • 5.12 Checking ONOS applications - PASS (tick)
  • 5.13 Starting Mininet Topology - PASS (tick)
  • 5.14 Check whether the flow count is bigger than 28 - PASS (tick)
  • 5.15 Check whether all flow status are ADDED - PASS (tick)
  • 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 5.18 Stopping Mininet - PASS (tick)
  • 5.19 Copying karaf logs - PASS (tick)

...

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Starting Mininet Topology - PASS (tick)
  • 6.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 6.13 Check whether all flow status are ADDED - PASS (tick)
  • 6.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 6.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 6.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.17 Stopping Mininet - PASS (tick)
  • 6.18 Copying karaf logs - PASS (tick)

Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Starting Mininet Topology - PASS (tick)
  • 7.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.13 Check whether all flow status are ADDED - PASS (tick)
  • 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 7.18 Stopping Mininet - PASS (tick)
  • 7.19 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Starting Mininet Topology - PASS (tick)
  • 8.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.13 Check whether all flow status are ADDED - PASS (tick)
  • 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 23
  • PASS (tick)
  • 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS (tick)
  • 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 8.20 Stopping Mininet - PASS (tick)
  • 8.21 Copying karaf logs - PASS (tick)

...

  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Starting Mininet Topology - PASS (tick)
  • 17.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.13 Check whether all flow status are ADDED - PASS (tick)
  • 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS (tick)
  • 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS (tick)
  • 17.18 Stopping Mininet - PASS (tick)
  • 17.19 Copying karaf logs - PASS (tick)

Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Starting Mininet Topology - PASS (tick)
  • 18.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 18.13 Check whether all flow status are ADDED - PASS (tick)
  • 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 18.20 Stopping Mininet - PASS (tick)
  • 18.21 Copying karaf logs - PASS (tick)

...

  • 26.1 Apply cell to environment - PASS (tick)
  • 26.2 Uninstalling Atomix - PASS (tick)
  • 26.3 Uninstalling ONOS package - PASS (tick)
  • 26.4 Installing Atomix - PASS (tick)
  • 26.5 Installing ONOS package - PASS (tick)
  • 26.6 Set up ONOS secure SSH - PASS (tick)
  • 26.7 Checking ONOS service - PASS (tick)
  • 26.8 Starting ONOS CLI sessions - PASS (tick)
  • 26.9 Checking ONOS nodes - PASS (tick)
  • 26.10 Checking ONOS applications - PASS (tick)
  • 26.11 Starting Mininet Topology - PASS (tick)
  • 26.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 26.13 Check whether all flow status are ADDED - PASS (tick)
  • 26.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 26.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 26.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE26 - PASS (tick)
  • 26.17 Stopping Mininet - PASS (tick)
  • 26.18 Copying karaf logs - PASS (tick)

Case 27: Bridging test between two untagged hosts on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 27.1 Apply cell to environment - PASS (tick)
  • 27.2 Uninstalling Atomix - PASS (tick)
  • 27.3 Uninstalling ONOS package - PASS (tick)
  • 27.4 Installing Atomix - PASS (tick)
  • 27.5 Installing ONOS package - PASS (tick)
  • 27.6 Set up ONOS secure SSH - PASS (tick)
  • 27.7 Checking ONOS service - PASS (tick)
  • 27.8 Starting ONOS CLI sessions - PASS (tick)
  • 27.9 Checking ONOS nodes - PASS (tick)
  • 27.10 Checking ONOS applications - PASS (tick)
  • 27.11 Starting Mininet Topology - PASS (tick)
  • 27.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 27.13 Check whether all flow status are ADDED - PASS (tick)
  • 27.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 27.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 17
  • PASS (tick)
  • 27.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE27 - PASS (tick)
  • 27.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE27 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 27.18 Stopping Mininet - PASS (tick)
  • 27.19 Copying karaf logs - PASS (tick)

...

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Starting Mininet Topology - PASS (tick)
  • 37.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.13 Check whether all flow status are ADDED - PASS (tick)
  • 37.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 37.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)
  • 37.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)
  • 37.18 Stopping Mininet - PASS (tick)
  • 37.19 Copying karaf logs - PASS (tick)

Case 38: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling Atomix - PASS (tick)
  • 38.3 Uninstalling ONOS package - PASS (tick)
  • 38.4 Installing Atomix - PASS (tick)
  • 38.5 Installing ONOS package - PASS (tick)
  • 38.6 Set up ONOS secure SSH - PASS (tick)
  • 38.7 Checking ONOS service - PASS (tick)
  • 38.8 Starting ONOS CLI sessions - PASS (tick)
  • 38.9 Checking ONOS nodes - PASS (tick)
  • 38.10 Checking ONOS applications - PASS (tick)
  • 38.11 Starting Mininet Topology - PASS (tick)
  • 38.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 38.13 Check whether all flow status are ADDED - PASS (tick)
  • 38.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 38.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 38.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 38.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)
  • 38.20 Stopping Mininet - PASS (tick)
  • 38.21 Copying karaf logs - PASS (tick)

...