Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-master/582/

...

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Starting Mininet Topology - PASS (tick)
  • 18.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 18.13 Check whether all flow status are ADDED - PASS (tick)
  • 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)
  • 18.20 Stopping Mininet - PASS (tick)
  • 18.21 Copying karaf logs - PASS (tick)

Case 25: Bridging test between two untagged hosts on vlan-native port, with single ToR and 3 ONOS instances -

...

PASS

  • 25.1 Apply cell to environment - PASS (tick)
  • 25.2 Uninstalling Atomix - PASS (tick)
  • 25.3 Uninstalling ONOS package - PASS (tick)
  • 25.4 Installing Atomix - PASS (tick)
  • 25.5 Installing ONOS package - PASS (tick)
  • 25.6 Set up ONOS secure SSH - PASS (tick)
  • 25.7 Checking ONOS service - PASS (tick)
  • 25.8 Starting ONOS CLI sessions - PASS (tick)
  • 25.9 Checking ONOS nodes - PASS (tick)
  • 25.10 Checking ONOS applications - PASS (tick)
  • 25.11 Starting Mininet Topology - PASS (tick)
  • 25.12 Check whether the flow count is bigger than 28 - FAIL (error)
    • Flow count looks wrong: 17
  • PASS (tick)
  • 25.13 Check whether all flow status are ADDED - PASS (tick)
  • 25.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
  • Flow count looks wrong: 17
  • PASS (tick)
  • 25.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE25 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 25.16 Stopping Mininet - PASS (tick)
  • 25.17 Copying karaf logs - PASS (tick)

...

  • 36.1 Apply cell to environment - PASS (tick)
  • 36.2 Uninstalling Atomix - PASS (tick)
  • 36.3 Uninstalling ONOS package - PASS (tick)
  • 36.4 Installing Atomix - PASS (tick)
  • 36.5 Installing ONOS package - PASS (tick)
  • 36.6 Set up ONOS secure SSH - PASS (tick)
  • 36.7 Checking ONOS service - PASS (tick)
  • 36.8 Starting ONOS CLI sessions - PASS (tick)
  • 36.9 Checking ONOS nodes - PASS (tick)
  • 36.10 Checking ONOS applications - PASS (tick)
  • 36.11 Starting Mininet Topology - PASS (tick)
  • 36.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 36.13 Check whether all flow status are ADDED - PASS (tick)
  • 36.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 36.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 36.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS (tick)
  • 36.17 Stopping Mininet - PASS (tick)
  • 36.18 Copying karaf logs - PASS (tick)

Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Starting Mininet Topology - PASS (tick)
  • 37.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.13 Check whether all flow status are ADDED - PASS (tick)
  • 37.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 37.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)
  • 37.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 37.18 Stopping Mininet - PASS (tick)
  • 37.19 Copying karaf logs - PASS (tick)

...

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling Atomix - PASS (tick)
  • 38.3 Uninstalling ONOS package - PASS (tick)
  • 38.4 Installing Atomix - PASS (tick)
  • 38.5 Installing ONOS package - PASS (tick)
  • 38.6 Set up ONOS secure SSH - PASS (tick)
  • 38.7 Checking ONOS service - PASS (tick)
  • 38.8 Starting ONOS CLI sessions - PASS (tick)
  • 38.9 Checking ONOS nodes - PASS (tick)
  • 38.10 Checking ONOS applications - PASS (tick)
  • 38.11 Starting Mininet Topology - PASS (tick)
  • 38.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 38.13 Check whether all flow status are ADDED - PASS (tick)
  • 38.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 38.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 38.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS (tick)
  • 38.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)
  • 38.20 Stopping Mininet - PASS (tick)
  • 38.21 Copying karaf logs - PASS (tick)

Case 45: Bridging test between untagged host and tagged host, with single ToR and 3 ONOS instances -

...

PASS

  • 45.1 Apply cell to environment - PASS (tick)
  • 45.2 Uninstalling Atomix - PASS (tick)
  • 45.3 Uninstalling ONOS package - PASS (tick)
  • 45.4 Installing Atomix - PASS (tick)
  • 45.5 Installing ONOS package - PASS (tick)
  • 45.6 Set up ONOS secure SSH - PASS (tick)
  • 45.7 Checking ONOS service - PASS (tick)
  • 45.8 Starting ONOS CLI sessions - PASS (tick)
  • 45.9 Checking ONOS nodes - PASS (tick)
  • 45.10 Checking ONOS applications - PASS (tick)
  • 45.11 Starting Mininet Topology - PASS (tick)
  • 45.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 45.13 Check whether all flow status are ADDED - PASS (tick)
  • 45.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 45.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE45 - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 45.16 Stopping Mininet - PASS (tick)
  • 45.17 Copying karaf logs - PASS (tick)

...

  • 46.1 Apply cell to environment - PASS (tick)
  • 46.2 Uninstalling Atomix - PASS (tick)
  • 46.3 Uninstalling ONOS package - PASS (tick)
  • 46.4 Installing Atomix - PASS (tick)
  • 46.5 Installing ONOS package - PASS (tick)
  • 46.6 Set up ONOS secure SSH - PASS (tick)
  • 46.7 Checking ONOS service - PASS (tick)
  • 46.8 Starting ONOS CLI sessions - PASS (tick)
  • 46.9 Checking ONOS nodes - PASS (tick)
  • 46.10 Checking ONOS applications - PASS (tick)
  • 46.11 Starting Mininet Topology - PASS (tick)
  • 46.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 46.13 Check whether all flow status are ADDED - PASS (tick)
  • 46.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 46.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 46.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE46 - PASS (tick)
  • 46.17 Stopping Mininet - PASS (tick)
  • 46.18 Copying karaf logs - PASS (tick)

Case 47: Bridging test between untagged host and tagged host, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 47.1 Apply cell to environment - PASS (tick)
  • 47.2 Uninstalling Atomix - PASS (tick)
  • 47.3 Uninstalling ONOS package - PASS (tick)
  • 47.4 Installing Atomix - PASS (tick)
  • 47.5 Installing ONOS package - PASS (tick)
  • 47.6 Set up ONOS secure SSH - PASS (tick)
  • 47.7 Checking ONOS service - PASS (tick)
  • 47.8 Starting ONOS CLI sessions - PASS (tick)
  • 47.9 Checking ONOS nodes - PASS (tick)
  • 47.10 Checking ONOS applications - PASS (tick)
  • 47.11 Starting Mininet Topology - PASS (tick)
  • 47.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 47.13 Check whether all flow status are ADDED - PASS (tick)
  • 47.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 47.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 47.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE47 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 47.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE47 - PASS (tick)
  • 47.18 Stopping Mininet - PASS (tick)
  • 47.19 Copying karaf logs - PASS (tick)

Case 48: Bridging test between untagged host and tagged host, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling Atomix - PASS (tick)
  • 48.3 Uninstalling ONOS package - PASS (tick)
  • 48.4 Installing Atomix - PASS (tick)
  • 48.5 Installing ONOS package - PASS (tick)
  • 48.6 Set up ONOS secure SSH - PASS (tick)
  • 48.7 Checking ONOS service - PASS (tick)
  • 48.8 Starting ONOS CLI sessions - PASS (tick)
  • 48.9 Checking ONOS nodes - PASS (tick)
  • 48.10 Checking ONOS applications - PASS (tick)
  • 48.11 Starting Mininet Topology - PASS (tick)
  • 48.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 48.13 Check whether all flow status are ADDED - PASS (tick)
  • 48.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 48.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 48.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 48.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 48.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 48.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS (tick)
  • 48.20 Stopping Mininet - PASS (tick)
  • 48.21 Copying karaf logs - PASS (tick)

...

  • 56.1 Apply cell to environment - PASS (tick)
  • 56.2 Uninstalling Atomix - PASS (tick)
  • 56.3 Uninstalling ONOS package - PASS (tick)
  • 56.4 Installing Atomix - PASS (tick)
  • 56.5 Installing ONOS package - PASS (tick)
  • 56.6 Set up ONOS secure SSH - PASS (tick)
  • 56.7 Checking ONOS service - PASS (tick)
  • 56.8 Starting ONOS CLI sessions - PASS (tick)
  • 56.9 Checking ONOS nodes - PASS (tick)
  • 56.10 Checking ONOS applications - PASS (tick)
  • 56.11 Starting Mininet Topology - PASS (tick)
  • 56.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 56.13 Check whether all flow status are ADDED - PASS (tick)
  • 56.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 56.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 56.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS (tick)
  • 56.17 Stopping Mininet - PASS (tick)
  • 56.18 Copying karaf logs - PASS (tick)

Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 57.1 Apply cell to environment - PASS (tick)
  • 57.2 Uninstalling Atomix - PASS (tick)
  • 57.3 Uninstalling ONOS package - PASS (tick)
  • 57.4 Installing Atomix - PASS (tick)
  • 57.5 Installing ONOS package - PASS (tick)
  • 57.6 Set up ONOS secure SSH - PASS (tick)
  • 57.7 Checking ONOS service - PASS (tick)
  • 57.8 Starting ONOS CLI sessions - PASS (tick)
  • 57.9 Checking ONOS nodes - PASS (tick)
  • 57.10 Checking ONOS applications - PASS (tick)
  • 57.11 Starting Mininet Topology - PASS (tick)
  • 57.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 57.13 Check whether all flow status are ADDED - PASS (tick)
  • 57.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 57.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 18
  • 57.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS (tick)
  • 57.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS (tick)
  • 57.18 Stopping Mininet - PASS (tick)
  • 57.19 Copying karaf logs - PASS (tick)

...