Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
...
commit cb787514974d13ccce4214997ba3e6c1c630e860 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Harshada Chaundkar [Harshada_Chaundkar@comcast.com]
AuthorDate: Mon Aug 5 15:33:30 2019 +0000
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Tue Sep 17 00:53:40 2019 +0000
Adding ACL flow for Table 60 for Ipv6
--
(cherry picked from commit 77958a5941bfa989f54858dee5515e137676e3db)
Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances -
...
FAIL
- 5.1 Constructing test variables - PASS
- 5.2 Apply cell to environment - PASS
- 5.3 Uninstalling Atomix - PASS
- 5.4 Uninstalling ONOS package - PASS
- 5.5 Creating ONOS package - PASS
- 5.6 Installing Atomix - PASS
- 5.7 Installing ONOS package - PASS
- 5.8 Set up ONOS secure SSH - PASS
- 5.9 Checking ONOS service - PASS
- 5.10 Starting ONOS CLI sessions - PASS
- 5.11 Checking ONOS nodes - PASS
- 5.12 Checking ONOS applications - PASS
- 5.13 Starting Mininet Topology - PASS
- 5.14 Check whether the flow count is bigger than 28 - PASS
- 5.15 Check whether all flow status are ADDED - PASS
- 5.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 5.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE5 - PASS FAIL
- IP connectivity failed
- 5.18 Stopping Mininet - PASS
- 5.19 Copying karaf logs - PASS
...
- 8.1 Apply cell to environment - PASS
- 8.2 Uninstalling Atomix - PASS
- 8.3 Uninstalling ONOS package - PASS
- 8.4 Installing Atomix - PASS
- 8.5 Installing ONOS package - PASS
- 8.6 Set up ONOS secure SSH - PASS
- 8.7 Checking ONOS service - PASS
- 8.8 Starting ONOS CLI sessions - PASS
- 8.9 Checking ONOS nodes - PASS
- 8.10 Checking ONOS applications - PASS
- 8.11 Starting Mininet Topology - PASS
- 8.12 Check whether the flow count is bigger than 212 - PASS
- 8.13 Check whether all flow status are ADDED - PASS
- 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS
- 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS
- 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - PASS
- 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - PASS
- 8.20 Stopping Mininet - PASS
- 8.21 Copying karaf logs - PASS
Case 15: Bridging test between two tagged hosts, with single ToR and 3 ONOS instances -
...
PASS
- 15.1 Apply cell to environment - PASS
- 15.2 Uninstalling Atomix - PASS
- 15.3 Uninstalling ONOS package - PASS
- 15.4 Installing Atomix - PASS
- 15.5 Installing ONOS package - PASS
- 15.6 Set up ONOS secure SSH - PASS
- 15.7 Checking ONOS service - PASS
- 15.8 Starting ONOS CLI sessions - PASS
- 15.9 Checking ONOS nodes - PASS
- 15.10 Checking ONOS applications - PASS
- 15.11 Starting Mininet Topology - PASS
- 15.12 Check whether the flow count is bigger than 28 - PASS
- 15.13 Check whether all flow status are ADDED - PASS
- 15.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS
- 15.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE15 - FAIL
- IP connectivity failed
- PASS
- 15.16 Stopping Mininet - PASS
- 15.17 Copying karaf logs - PASS
...
- 36.1 Apply cell to environment - PASS
- 36.2 Uninstalling Atomix - PASS
- 36.3 Uninstalling ONOS package - PASS
- 36.4 Installing Atomix - PASS
- 36.5 Installing ONOS package - PASS
- 36.6 Set up ONOS secure SSH - PASS
- 36.7 Checking ONOS service - PASS
- 36.8 Starting ONOS CLI sessions - PASS
- 36.9 Checking ONOS nodes - PASS
- 36.10 Checking ONOS applications - PASS
- 36.11 Starting Mininet Topology - PASS
- 36.12 Check whether the flow count is bigger than 74 - PASS
- 36.13 Check whether all flow status are ADDED - PASS
- 36.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 36.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS
- 36.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE36 - PASS
- 36.17 Stopping Mininet - PASS
- 36.18 Copying karaf logs - PASS
Case 37: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 37.1 Apply cell to environment - PASS
- 37.2 Uninstalling Atomix - PASS
- 37.3 Uninstalling ONOS package - PASS
- 37.4 Installing Atomix - PASS
- 37.5 Installing ONOS package - PASS
- 37.6 Set up ONOS secure SSH - PASS
- 37.7 Checking ONOS service - PASS
- 37.8 Starting ONOS CLI sessions - PASS
- 37.9 Checking ONOS nodes - PASS
- 37.10 Checking ONOS applications - PASS
- 37.11 Starting Mininet Topology - PASS
- 37.12 Check whether the flow count is bigger than 74 - PASS
- 37.13 Check whether all flow status are ADDED - PASS
- 37.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS
- 37.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL Flow count looks wrong: 18
- PASS
- 37.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS
- 37.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - FAIL IP connectivity failed
- PASS
- 37.18 Stopping Mininet - PASS
- 37.19 Copying karaf logs - PASS
...