Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.2/29/

...

commit 63c69a74c6a9604ebfaa0e2268fafdf59f070c94 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Harshada Chaundkar [Harshada_Chaundkar@comcast.com]
AuthorDate: Wed Sep 25 17:42:33 2019 +0000
Commit: Charles Chan [rascov@gmail.com]
CommitDate: Wed Sep 25 13:12:42 2019 -0700

Fpm additional logs
--
(cherry picked from commit a533f14b31bc38a57a44f1e839edd25fac745c67)

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Starting Mininet Topology - PASS (tick)
  • 13.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.15 Check whether all flow status are ADDED - PASS (tick)
  • 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.19 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.20 Check whether all flow status are ADDED - PASS (tick)
  • 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 13.22 Stopping Mininet - PASS (tick)
  • 13.23 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.13 Check whether all flow status are ADDED - PASS (tick)
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.19 Check whether all flow status are ADDED - PASS (tick)
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

...

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling Atomix - PASS (tick)
  • 53.3 Uninstalling ONOS package - PASS (tick)
  • 53.4 Installing Atomix - PASS (tick)
  • 53.5 Installing ONOS package - PASS (tick)
  • 53.6 Set up ONOS secure SSH - PASS (tick)
  • 53.7 Checking ONOS service - PASS (tick)
  • 53.8 Starting ONOS CLI sessions - PASS (tick)
  • 53.9 Checking ONOS nodes - PASS (tick)
  • 53.10 Checking ONOS applications - PASS (tick)
  • 53.11 Starting Mininet Topology - PASS (tick)
  • 53.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.13 Check whether all flow status are ADDED - PASS (tick)
  • 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 53.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.19 Check whether all flow status are ADDED - PASS (tick)
  • 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.22 Stopping Mininet - PASS (tick)
  • 53.23 Copying karaf logs - PASS (tick)

Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling Atomix - PASS (tick)
  • 63.3 Uninstalling ONOS package - PASS (tick)
  • 63.4 Installing Atomix - PASS (tick)
  • 63.5 Installing ONOS package - PASS (tick)
  • 63.6 Set up ONOS secure SSH - PASS (tick)
  • 63.7 Checking ONOS service - PASS (tick)
  • 63.8 Starting ONOS CLI sessions - PASS (tick)
  • 63.9 Checking ONOS nodes - PASS (tick)
  • 63.10 Checking ONOS applications - PASS (tick)
  • 63.11 Starting Mininet Topology - PASS (tick)
  • 63.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.13 Check whether all flow status are ADDED - PASS (tick)
  • 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS (tick)
  • 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 63.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.19 Check whether all flow status are ADDED - PASS (tick)
  • 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.22 Stopping Mininet - PASS (tick)
  • 63.23 Copying karaf logs - PASS (tick)

...

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling Atomix - PASS (tick)
  • 113.3 Uninstalling ONOS package - PASS (tick)
  • 113.4 Installing Atomix - PASS (tick)
  • 113.5 Installing ONOS package - PASS (tick)
  • 113.6 Set up ONOS secure SSH - PASS (tick)
  • 113.7 Checking ONOS service - PASS (tick)
  • 113.8 Starting ONOS CLI sessions - PASS (tick)
  • 113.9 Checking ONOS nodes - PASS (tick)
  • 113.10 Checking ONOS applications - PASS (tick)
  • 113.11 Starting Mininet Topology - PASS (tick)
  • 113.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.13 Check whether all flow status are ADDED - PASS (tick)
  • 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.22 Stopping Mininet - PASS (tick)
  • 113.23 Copying karaf logs - PASS (tick)

Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling Atomix - PASS (tick)
  • 123.3 Uninstalling ONOS package - PASS (tick)
  • 123.4 Installing Atomix - PASS (tick)
  • 123.5 Installing ONOS package - PASS (tick)
  • 123.6 Set up ONOS secure SSH - PASS (tick)
  • 123.7 Checking ONOS service - PASS (tick)
  • 123.8 Starting ONOS CLI sessions - PASS (tick)
  • 123.9 Checking ONOS nodes - PASS (tick)
  • 123.10 Checking ONOS applications - PASS (tick)
  • 123.11 Starting Mininet Topology - PASS (tick)
  • 123.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.13 Check whether all flow status are ADDED - PASS (tick)
  • 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)
  • 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.19 Check whether all flow status are ADDED - PASS (tick)
  • 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)
  • 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)
  • 123.22 Stopping Mininet - PASS (tick)
  • 123.23 Copying karaf logs - PASS (tick)

...

  • 133.1 Apply cell to environment - PASS (tick)
  • 133.2 Uninstalling Atomix - PASS (tick)
  • 133.3 Uninstalling ONOS package - PASS (tick)
  • 133.4 Installing Atomix - PASS (tick)
  • 133.5 Installing ONOS package - PASS (tick)
  • 133.6 Set up ONOS secure SSH - PASS (tick)
  • 133.7 Checking ONOS service - PASS (tick)
  • 133.8 Starting ONOS CLI sessions - PASS (tick)
  • 133.9 Checking ONOS nodes - PASS (tick)
  • 133.10 Checking ONOS applications - PASS (tick)
  • 133.11 Starting Mininet Topology - PASS (tick)
  • 133.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 133.13 Check whether all flow status are ADDED - PASS (tick)
  • 133.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_Before - PASS (tick)
  • 133.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_Before - PASS (tick)
  • 133.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 133.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 133.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 133.19 Check whether all flow status are ADDED - PASS (tick)
  • 133.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE133_After - PASS (tick)
  • 133.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE133_After - PASS (tick)
  • 133.22 Stopping Mininet - PASS (tick)
  • 133.23 Copying karaf logs - PASS (tick)

Case 143: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 143.1 Apply cell to environment - PASS (tick)
  • 143.2 Uninstalling Atomix - PASS (tick)
  • 143.3 Uninstalling ONOS package - PASS (tick)
  • 143.4 Installing Atomix - PASS (tick)
  • 143.5 Installing ONOS package - PASS (tick)
  • 143.6 Set up ONOS secure SSH - PASS (tick)
  • 143.7 Checking ONOS service - PASS (tick)
  • 143.8 Starting ONOS CLI sessions - PASS (tick)
  • 143.9 Checking ONOS nodes - PASS (tick)
  • 143.10 Checking ONOS applications - PASS (tick)
  • 143.11 Starting Mininet Topology - PASS (tick)
  • 143.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 143.13 Check whether all flow status are ADDED - PASS (tick)
  • 143.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE143_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 143.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_Before - PASS (tick)
  • 143.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 143.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 143.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 143.19 Check whether all flow status are ADDED - PASS (tick)
  • 143.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE143_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 143.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE143_After - PASS (tick)
  • 143.22 Stopping Mininet - PASS (tick)
  • 143.23 Copying karaf logs - PASS (tick)

...

  • 183.1 Apply cell to environment - PASS (tick)
  • 183.2 Uninstalling Atomix - PASS (tick)
  • 183.3 Uninstalling ONOS package - PASS (tick)
  • 183.4 Installing Atomix - PASS (tick)
  • 183.5 Installing ONOS package - PASS (tick)
  • 183.6 Set up ONOS secure SSH - PASS (tick)
  • 183.7 Checking ONOS service - PASS (tick)
  • 183.8 Starting ONOS CLI sessions - PASS (tick)
  • 183.9 Checking ONOS nodes - PASS (tick)
  • 183.10 Checking ONOS applications - PASS (tick)
  • 183.11 Starting Mininet Topology - PASS (tick)
  • 183.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.13 Check whether all flow status are ADDED - PASS (tick)
  • 183.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_Before - PASS (tick)
  • 183.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_Before - PASS (tick)
  • 183.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 183.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 183.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 183.19 Check whether all flow status are ADDED - PASS (tick)
  • 183.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE183_After - PASS (tick)
  • 183.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE183_After - PASS (tick)
  • 183.22 Stopping Mininet - PASS (tick)
  • 183.23 Copying karaf logs - PASS (tick)

Case 193: Changing port configuration from tagged 20 and native 10 to untagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 193.1 Apply cell to environment - PASS (tick)
  • 193.2 Uninstalling Atomix - PASS (tick)
  • 193.3 Uninstalling ONOS package - PASS (tick)
  • 193.4 Installing Atomix - PASS (tick)
  • 193.5 Installing ONOS package - PASS (tick)
  • 193.6 Set up ONOS secure SSH - PASS (tick)
  • 193.7 Checking ONOS service - PASS (tick)
  • 193.8 Starting ONOS CLI sessions - PASS (tick)
  • 193.9 Checking ONOS nodes - PASS (tick)
  • 193.10 Checking ONOS applications - PASS (tick)
  • 193.11 Starting Mininet Topology - PASS (tick)
  • 193.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.13 Check whether all flow status are ADDED - PASS (tick)
  • 193.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE193_Before - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 193.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE193_Before - PASS (tick)
  • 193.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 193.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 193.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 193.19 Check whether all flow status are ADDED - PASS (tick)
  • 193.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE193_After - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 193.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE193_After - PASS (tick)
  • 193.22 Stopping Mininet - PASS (tick)
  • 193.23 Copying karaf logs - PASS (tick)

...