Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.15/1324/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRHighAvailability_onos-1.15_20-builds_graph.jpg", alt="SRHighAvailability", style="width:525px;height:350px;border:0">

commit d57669f27c7f35f2c9f41ec432213e2de334b412 fb73f668dab68515cae00533f006067d068da7e1 (HEAD -] onos-1.15, origin/onos-1.15)
Author: stevenchiu30801 Charles Chan [steven30801@gmailrascov@gmail.com]
AuthorDate: Fri Thu Oct 11 0517 20:2609:47 45 2019 +0800-0700
Commit: Charles Chan [charles@opennetworkingrascov@gmail.orgcom]
CommitDate: Mon Oct 14 07:25:18 2019 +0000
Fix Xconnect example on web docs
--
(cherry picked from commit ea5ea0128f6bac0b3ed1670cae71c83000807413)
Fri Nov 1 13:12:17 2019 -0700

Added table miss flow for ovs-ofdpa punt table

Case 1: High Availability tests - ONOS failures 2x2 Leaf-spine - FAIL

...

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.18 Killing ONOS instances with index(es): [10] - PASS (tick)
  • 2.19 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 2.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Failure1 - PASS (tick)
  • 2.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Failure1 - PASS (tick)
  • 2.23 Recovering ONOS instances with index(es): [10] - PASS (tick)
  • 2.24 Checking if ONOS CLI is ready - PASS (tick)
  • 2.25 Checking ONOS nodes - PASS (tick)
  • 2.26 Check number of topology elements - PASS (tick)
  • 2.27 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.28 Check whether all flow status are ADDED - PASS (tick)
  • 2.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 2.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Recovery1 - PASS (tick)
  • 2.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Recovery1 - PASS (tick)
  • 2.32 Killing ONOS instances with index(es): [12] - PASS (tick)
  • 2.33 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 2.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Failure2 - PASS (tick)
  • 2.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Failure2 - PASS (tick)
  • 2.37 Recovering ONOS instances with index(es): [12] - PASS (tick)
  • 2.38 Checking if ONOS CLI is ready - PASS (tick)
  • 2.39 Checking ONOS nodes - PASS (tick)
  • 2.40 Check number of topology elements - PASS (tick)
  • 2.41 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.42 Check whether all flow status are ADDED - PASS (tick)
  • 2.43 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 2.44 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Recovery2 - PASS (tick)
  • 2.45 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Recovery2 - PASS (tick)
  • 2.46 Killing ONOS instances with index(es): [21] - PASS (tick)
  • 2.47 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.48 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 2.49 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Failure3 - PASS (tick)
  • 2.50 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Failure3 - PASS (tick)
  • 2.51 Recovering ONOS instances with index(es): [21] - PASS (tick)
  • 2.52 Checking if ONOS CLI is ready - PASS (tick)
  • 2.53 Checking ONOS nodes - PASS (tick)
  • 2.54 Check number of topology elements - PASS (tick)
  • 2.55 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.56 Check whether all flow status are ADDED - PASS (tick)
  • 2.57 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 2.58 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Recovery3 - PASS (tick)
  • 2.59 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Recovery3 - PASS (tick)
  • 2.60 Stopping Mininet - PASS (tick)
  • 2.61 Copying karaf logs - PASS (tick)

...