- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - PASS
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS
Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling Atomix - PASS
- 33.3 Uninstalling ONOS package - PASS
- 33.4 Installing Atomix - PASS
- 33.5 Installing ONOS package - PASS
- 33.6 Set up ONOS secure SSH - PASS
- 33.7 Checking ONOS service - PASS
- 33.8 Starting ONOS CLI sessions - PASS
- 33.9 Checking ONOS nodes - PASS
- 33.10 Checking ONOS applications - PASS
- 33.11 Starting Mininet Topology - PASS
- 33.12 Check whether the flow count is bigger than 104 - PASS
- 33.13 Check whether all flow status are ADDED - PASS
- 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS
- 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS
- 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 33.18 Check whether the flow count is bigger than 104 - PASS
- 33.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS
- 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS
- 33.22 Stopping Mininet - PASS
- 33.23 Copying karaf logs - PASS
Case 43: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 43.1 Apply cell to environment - PASS
- 43.2 Uninstalling Atomix - PASS
- 43.3 Uninstalling ONOS package - PASS
- 43.4 Installing Atomix - PASS
- 43.5 Installing ONOS package - PASS
- 43.6 Set up ONOS secure SSH - PASS
- 43.7 Checking ONOS service - PASS
- 43.8 Starting ONOS CLI sessions - PASS
- 43.9 Checking ONOS nodes - PASS
- 43.10 Checking ONOS applications - PASS
- 43.11 Starting Mininet Topology - PASS
- 43.12 Check whether the flow count is bigger than 104 - PASS
- 43.13 Check whether all flow status are ADDED - PASS
- 43.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS
- 43.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS
- 43.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 43.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 43.18 Check whether the flow count is bigger than 104 - PASS
- 43.19 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- PASS
- 43.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS
- 43.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS
- 43.22 Stopping Mininet - PASS
- 43.23 Copying karaf logs - PASS
Case 53: Changing port configuration from untagged 10 to tagged 20 with native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
PASS
- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling Atomix - PASS
- 53.3 Uninstalling ONOS package - PASS
- 53.4 Installing Atomix - PASS
- 53.5 Installing ONOS package - PASS
- 53.6 Set up ONOS secure SSH - PASS
- 53.7 Checking ONOS service - PASS
- 53.8 Starting ONOS CLI sessions - PASS
- 53.9 Checking ONOS nodes - PASS
- 53.10 Checking ONOS applications - PASS
- 53.11 Starting Mininet Topology - PASS
- 53.12 Check whether the flow count is bigger than 104 - PASS
- 53.13 Check whether all flow status are ADDED - PASS
- 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - FAIL
- IP connectivity failed
- PASS
- 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - FAIL
- IP connectivity failed
- PASS
- 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- Flow count looks wrong: 21
- PASS
- 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 53.18 Check whether the flow count is bigger than 104 - PASS
- 53.19 Check whether all flow status are ADDED - PASS
- 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - FAIL IP connectivity failed
- PASS
- 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - FAIL
- IP connectivity failed
- PASS
- 53.22 Stopping Mininet - PASS
- 53.23 Copying karaf logs - PASS
Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Installing Atomix - PASS
- 63.5 Installing ONOS package - PASS
- 63.6 Set up ONOS secure SSH - PASS
- 63.7 Checking ONOS service - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Starting Mininet Topology - PASS
- 63.12 Check whether the flow count is bigger than 104 - PASS
- 63.13 Check whether all flow status are ADDED - PASS
- 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.18 Check whether the flow count is bigger than 104 - PASS
- 63.19 Check whether all flow status are ADDED - PASS FAIL
- Flow status is wrong!
- 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.22 Stopping Mininet - PASS
- 63.23 Copying karaf logs - PASS
...
- 153.1 Apply cell to environment - PASS
- 153.2 Uninstalling Atomix - PASS
- 153.3 Uninstalling ONOS package - PASS
- 153.4 Installing Atomix - PASS
- 153.5 Installing ONOS package - PASS
- 153.6 Set up ONOS secure SSH - PASS
- 153.7 Checking ONOS service - PASS
- 153.8 Starting ONOS CLI sessions - PASS
- 153.9 Checking ONOS nodes - PASS
- 153.10 Checking ONOS applications - PASS
- 153.11 Starting Mininet Topology - PASS
- 153.12 Check whether the flow count is bigger than 106 - PASS
- 153.13 Check whether all flow status are ADDED - PASS
- 153.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_Before - PASS
- 153.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_Before - PASS
- 153.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 153.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 153.18 Check whether the flow count is bigger than 106 - PASS
- 153.19 Check whether all flow status are ADDED - PASS
- 153.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE153_After - PASS
- 153.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE153_After - PASS
- 153.22 Stopping Mininet - PASS
- 153.23 Copying karaf logs - PASS
Case 163: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -
...
FAIL
- 163.1 Apply cell to environment - PASS
- 163.2 Uninstalling Atomix - PASS
- 163.3 Uninstalling ONOS package - PASS
- 163.4 Installing Atomix - PASS
- 163.5 Installing ONOS package - PASS
- 163.6 Set up ONOS secure SSH - PASS
- 163.7 Checking ONOS service - PASS
- 163.8 Starting ONOS CLI sessions - PASS
- 163.9 Checking ONOS nodes - PASS
- 163.10 Checking ONOS applications - PASS
- 163.11 Starting Mininet Topology - PASS
- 163.12 Check whether the flow count is bigger than 106 - PASS FAIL
- Flow count looks wrong: 81
- 163.13 Check whether all flow status are ADDED - PASS
- 163.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE163_Before - PASS FAIL
- IP connectivity failed
- 163.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_Before - PASS
- 163.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 20
- 163.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS FAIL
- Flow count looks wrong: 17
- 163.18 Check whether the flow count is bigger than 106 - PASS FAIL
- Flow count looks wrong: 86
- 163.19 Check whether all flow status are ADDED - PASS
- 163.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE163_After - PASS FAIL
- IP connectivity failed
- 163.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE163_After - PASS
- 163.22 Stopping Mininet - PASS
- 163.23 Copying karaf logs - PASS
...