Case 1: Constructing test variables and building ONOS package - PASS

...

  • 22.1 Send arping between all hosts - PASS (tick)

Case 23: Compare ONOS Topology view to Mininet topology -

...

PASS

Compare topology elements between Mininet and ONOS

  • 23.1 Comparing Mininet topology to ONOS topology - FAIL (error)
    • ONOS incorrectly discovered the topology
  • PASS (tick)

Case 31: Install point intents between 2 packet layer device and ping the hosts - FAIL

...

  • 31.1 Adding point intents - PASS (tick)
  • 31.2 Ping h1 and h5 - FAIL (error)
    • Failed to add point intents Skipping the rest of this case. ping between h1 and h5

Case 32: Test add host intents between optical layer host - FAIL

...

  • 32.1 Adding host intents to h1 and h2 - FAIL (error)
    • Some of the intents are not in INSTALLED state
  • 32.2 Removing host intents - PASS (tick)FAIL (error)
    • Failed to remove host intents

Case 14: Stop Mininet topology - PASS

...

  • 22.1 Send arping between all hosts - PASS (tick)

Case 23: Compare ONOS Topology view to Mininet topology -

...

PASS

Compare topology elements between Mininet and ONOS

  • 23.1 Comparing Mininet topology to ONOS topology - FAIL (error)
    • ONOS incorrectly discovered the topology
  • PASS (tick)

Case 31: Install point intents between 2 packet layer device and ping the hosts -

...

PASS

This testcase adds bidirectional point intents between 2 packet layer( mininet ) devices and ping mininet hosts

  • 31.1 Adding point intents - FAIL (error)
  • Failed to add point intents
  • Skipping the rest of this case.
  • PASS (tick)
  • 31.2 Ping h1 and h5 - PASS (tick)

Case 32: Test add host intents between optical layer host - FAIL

...

  • 32.1 Adding host intents to h1 and h2 - FAIL (error)
  • Some of the intents are not in INSTALLED state
  • PASS (tick)
  • 32.2 Pinging h1 and h2 - PASS (tick)
  • 32.2 3 Removing host intents - PASS (tick)FAIL (error)
    • Failed to remove host intents

Case 14: Stop Mininet topology - PASS

...

  • 10.1 Starting mininet and LINC-OE - PASS (tick)

Case 17: Enable intent compilation using Flow Objectives -

...

PASS

  • 17.1 Enabling Flow Objectives - FAIL (error)
  • Failed to activate Flow Objectives
  • PASS (tick)

Case 21: Running Pingall - PASS

...

  • 22.1 Send arping between all hosts - PASS (tick)

Case 23: Compare ONOS Topology view to Mininet topology -

...

PASS

Compare topology elements between Mininet and ONOS

  • 23.1 Comparing Mininet topology to ONOS topology - FAIL (error)
  • ONOS incorrectly discovered the topology
  • PASS (tick)

Case 31: Install point intents between 2 packet layer device and ping the hosts -

...

PASS

This testcase adds bidirectional point intents between 2 packet layer( mininet ) devices and ping mininet hosts

  • 31.1 Adding point intents - FAIL (error)
  • Failed to add point intents
  • Skipping the rest of this case.
  • PASS (tick)
  • 31.2 Ping h1 and h5 - PASS (tick)

Case 32: Test add host intents between optical layer host - FAIL

...

  • 32.1 Adding host intents to h1 and h2 - FAIL (error)
  • Some of the intents are not in INSTALLED state
  • PASS (tick)
  • 32.2 Pinging h1 and h2 - PASS (tick)
  • 32.2 3 Removing host intents - PASS (tick)FAIL (error)
    • Failed to remove host intents

Case 14: Stop Mininet topology - PASS

...

  • 10.1 Starting mininet and LINC-OE - PASS (tick)

Case 17: Enable intent compilation using Flow Objectives -

...

PASS

  • 17.1 Enabling Flow Objectives - FAIL (error)
  • Failed to activate Flow Objectives
  • PASS (tick)

Case 21: Running Pingall - PASS

...

  • 22.1 Send arping between all hosts - PASS (tick)

Case 23: Compare ONOS Topology view to Mininet topology -

...

PASS

Compare topology elements between Mininet and ONOS

  • 23.1 Comparing Mininet topology to ONOS topology - FAIL (error)
    • ONOS incorrectly discovered the topology
  • PASS (tick)

Case 31: Install point intents between 2 packet layer device and ping the hosts -

...

PASS

This testcase adds bidirectional point intents between 2 packet layer( mininet ) devices and ping mininet hosts

  • 31.1 Adding point intents - FAIL (error)
  • Failed to add point intents
  • Skipping the rest of this case.
  • PASS (tick)
  • 31.2 Ping h1 and h5 - PASS (tick)

Case 32: Test add host intents between optical layer host - FAIL

...

  • 32.1 Adding host intents to h1 and h2 - PASS (tick)
  • 32.2 Pinging h1 and h2 - FAIL (error)
    • Some of the intents are not in INSTALLED state Pinged failed between h1 and h2
  • 32.2 3 Removing host intents - PASS (tick)FAIL (error)
    • Failed to remove host intents

Case 14: Stop Mininet topology - PASS

...