HAswapNodes at 16 Jun 2016 23:21:49

commit 5e1f42d8ebc6dfa1ed0347d750fb9a6562addbf2 (HEAD, tag: 1.6.0-rc3)
Author: Thomas Vachuska [tom@onlab.us]
AuthorDate: Thu Jun 16 20:07:09 2016 -0700
Commit: Thomas Vachuska [tom@onlab.us]
CommitDate: Thu Jun 16 20:07:09 2016 -0700

Tagging 1.6.0-rc3

Case 1: Setting up test environment - PASS

Setup the test environment including installing ONOS, starting Mininet and ONOScli sessions.

  • 1.1 Create cell file - No Result (warning)
  • 1.2 Applying cell variable to environment - PASS (tick)
  • 1.3 Verify connectivity to cell - PASS (tick)
  • 1.4 Setup server for cluster metadata file - PASS (tick)
  • 1.5 Generate initial metadata file - PASS (tick)
  • 1.6 Starting Mininet - PASS (tick)
  • 1.7 Git checkout and pull master - No Result (warning)
  • 1.8 Using mvn clean install - PASS (tick)
  • 1.9 Copying backup config files - PASS (tick)
  • 1.10 Creating ONOS package - PASS (tick)
  • 1.11 Installing ONOS package - PASS (tick)
  • 1.12 Checking if ONOS is up yet - PASS (tick)
  • 1.13 Checking ONOS nodes - PASS (tick)
  • 1.14 Activate apps defined in the params file - No Result (warning)
  • 1.15 Set ONOS configurations - PASS (tick)
  • 1.16 App Ids check - PASS (tick)

Case 2: Assigning devices to controllers - PASS

Assign switches to ONOS using 'ovs-vsctl' and check that an ONOS node becomes the master of the device.

  • 2.1 Assign switches to controllers - PASS (tick)

Case 8: Compare ONOS Topology view to Mininet topology - FAIL

Compare topology objects between Mininet and ONOS

  • 8.1 Comparing ONOS topology to MN topology - FAIL (error)
    • ONOS topology don't match Mininet
  • 8.2 Hosts view is consistent across all ONOS nodes - PASS (tick)
  • 8.3 Hosts information is correct - PASS (tick)
  • 8.4 Host attachment points to the network - PASS (tick)
  • 8.5 Clusters view is consistent across all ONOS nodes - PASS (tick)
  • 8.6 There is only one SCC - FAIL (error)
    • ONOS shows 27 SCCs
  • 8.7 Device information is correct - PASS (tick)
  • 8.8 Links are correct - FAIL (error)
    • Links are incorrect
  • 8.9 Hosts are correct - PASS (tick)
  • 8.10 Checking ONOS nodes - FAIL (error)
    • Nodes check NOT successful

Case 21: Assigning Controller roles for switches - PASS

Check that ONOS is connected to each device. Then manually assign mastership to specific ONOS nodes using 'device-role'

  • 21.1 Assign mastership of switches to specific controllers - PASS (tick)
  • 21.2 Check mastership was correctly assigned - PASS (tick)