Have questions? Stuck? Please check our FAQ for some common questions and answers.

Description

This test is described in more detail in the following links, which we refer to:

Test plan: Experiment F Plan - Flow Subsystem Burst Throughput

Test result: Master: Experiment F - Flow Subsystem Burst Throughput

The difference is that we use the IXIA tester to simulate openflow switches, total 100 switches was set and 100000 flows for each switch, the results show below.

Test Results

  • Flow_mode Rate 

     

    Flow_mode rate(P/S)

    Single mode(ONOS)

    Flow_mode rate(P/S)

    Three mode(ONOS1)

    Flow_mode rate(P/S)

    Three mode(ONOS2)

    Flow_mode rate(P/S)

    Three mode(ONOS3)

    First1076013112125698941
    Second114148383786511244
    Third11892855873768477
    Fourth12029798377909028
    Fifth1217413387130877666
    Sixth11319912689058335
    Seventh1122514442135467906
    Eighth1258510446974812318
    Ninth120651045698788406
    Tenth104139638923713580
    Avg1158710553100009590
    Std644218821651939
  • Histogram of Flow_mod rate


  • Histogram of Flow_mod std

 

As the histograms show, in the case of three nodes, flow_mod is three times the case of a single node, but the standard deviation is much higher than single node.

 