Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 21 Next »

SROnosFailure at 06 Mar 2020 21:31:05

SROnosFailure

commit 13a62a6e9aa436b2db7d8f6e2affa799ad103310 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Jian Li [pyguni@gmail.com]
AuthorDate: Tue Feb 25 05:04:14 2020 +0900
Commit: Jian Li [pyguni@gmail.com]
CommitDate: Wed Mar 4 08:48:37 2020 +0000

Fix: re-order the flow rule and group rule install/uninstall sequence

Case 1: ONOS Failure test with 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 1.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.24 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.25 Checking if ONOS CLI is ready - PASS (tick)
  • 1.26 Checking ONOS nodes - PASS (tick)
  • 1.27 Check number of topology elements - PASS (tick)
  • 1.28 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.29 Check whether all flow status are ADDED - PASS (tick)
  • 1.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.33 Stopping Mininet - PASS (tick)
  • 1.34 Copying karaf logs - PASS (tick)

Case 2: ONOS Failure test with 4x4 Leaf-spine - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 2.19 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.23 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 2.24 Checking if ONOS CLI is ready - PASS (tick)
  • 2.25 Checking ONOS nodes - PASS (tick)
  • 2.26 Check number of topology elements - PASS (tick)
  • 2.27 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.28 Check whether all flow status are ADDED - PASS (tick)
  • 2.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.32 Stopping Mininet - PASS (tick)
  • 2.33 Copying karaf logs - PASS (tick)

Case 3: ONOS Failure test with single switch - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Starting Mininet Topology - PASS (tick)
  • 3.13 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.14 Check whether all flow status are ADDED - PASS (tick)
  • 3.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.18 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 3.19 Check number of topology elements - PASS (tick)
  • 3.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.23 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 3.24 Checking if ONOS CLI is ready - PASS (tick)
  • 3.25 Checking ONOS nodes - PASS (tick)
  • 3.26 Check number of topology elements - PASS (tick)
  • 3.27 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.28 Check whether all flow status are ADDED - PASS (tick)
  • 3.29 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Recovery - PASS (tick)
  • 3.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 3.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 3.32 Stopping Mininet - PASS (tick)
  • 3.33 Copying karaf logs - PASS (tick)
  • No labels