Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 33 Next »

SRHighAvailability at 20 Jun 2020 23:41:22

SRHighAvailability

commit 6dc062a01cfefdbfd8efc8e8ed73e66400bdb750 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Seyeon Jeong [seyeon@opennetworking.org]
AuthorDate: Fri Feb 28 01:17:34 2020 -0800
Commit: Seyeon Jeong [seyeon@opennetworking.org]
CommitDate: Wed Jun 17 19:32:14 2020 -0700

[AETHER-76] Complete T3 offline mode
--
(cherry picked from commit c3803e7fad5fb28ecf3e83253f183a34936be4a0)

Case 1: High Availability tests - ONOS failures 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 1.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 1.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 1.24 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.25 Checking if ONOS CLI is ready - PASS (tick)
  • 1.26 Checking ONOS nodes - PASS (tick)
  • 1.27 Check number of topology elements - PASS (tick)
  • 1.28 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.29 Check whether all flow status are ADDED - PASS (tick)
  • 1.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 1.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 1.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 1.33 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 1.34 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 1.35 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 1.36 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 1.37 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 1.38 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 1.39 Checking if ONOS CLI is ready - PASS (tick)
  • 1.40 Checking ONOS nodes - PASS (tick)
  • 1.41 Check number of topology elements - PASS (tick)
  • 1.42 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.43 Check whether all flow status are ADDED - PASS (tick)
  • 1.44 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 1.45 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 1.46 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 1.47 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 1.48 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 1.49 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 1.50 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 1.51 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 1.52 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 1.53 Checking if ONOS CLI is ready - PASS (tick)
  • 1.54 Checking ONOS nodes - PASS (tick)
  • 1.55 Check number of topology elements - PASS (tick)
  • 1.56 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.57 Check whether all flow status are ADDED - PASS (tick)
  • 1.58 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 1.59 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 1.60 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 1.61 Stopping Mininet - PASS (tick)
  • 1.62 Copying karaf logs - PASS (tick)

Case 2: High Availability tests - ONOS random failures 2x2 Leaf-spine - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 2.19 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 2.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 2.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 2.23 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 2.24 Checking if ONOS CLI is ready - PASS (tick)
  • 2.25 Checking ONOS nodes - PASS (tick)
  • 2.26 Check number of topology elements - PASS (tick)
  • 2.27 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.28 Check whether all flow status are ADDED - PASS (tick)
  • 2.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 2.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 2.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 2.32 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 2.33 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 2.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 2.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 2.37 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 2.38 Checking if ONOS CLI is ready - PASS (tick)
  • 2.39 Checking ONOS nodes - PASS (tick)
  • 2.40 Check number of topology elements - PASS (tick)
  • 2.41 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.42 Check whether all flow status are ADDED - PASS (tick)
  • 2.43 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 2.44 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 2.45 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 2.46 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 2.47 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.48 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 2.49 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 2.50 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 2.51 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 2.52 Checking if ONOS CLI is ready - PASS (tick)
  • 2.53 Checking ONOS nodes - PASS (tick)
  • 2.54 Check number of topology elements - PASS (tick)
  • 2.55 Check whether the flow count is bigger than 116 - PASS (tick)
  • 2.56 Check whether all flow status are ADDED - PASS (tick)
  • 2.57 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE2_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 2.58 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 2.59 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 2.60 Stopping Mininet - PASS (tick)
  • 2.61 Copying karaf logs - PASS (tick)

Case 3: High Availability tests - ONOS failures 4x4 Leaf-spine - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Starting Mininet Topology - PASS (tick)
  • 3.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 3.14 Check whether all flow status are ADDED - PASS (tick)
  • 3.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.18 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 3.19 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 3.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 3.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 3.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 3.23 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 3.24 Checking if ONOS CLI is ready - PASS (tick)
  • 3.25 Checking ONOS nodes - PASS (tick)
  • 3.26 Check number of topology elements - PASS (tick)
  • 3.27 Check whether the flow count is bigger than 350 - PASS (tick)
  • 3.28 Check whether all flow status are ADDED - PASS (tick)
  • 3.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 3.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 3.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 3.32 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 3.33 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 3.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 3.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 3.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 3.37 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 3.38 Checking if ONOS CLI is ready - PASS (tick)
  • 3.39 Checking ONOS nodes - PASS (tick)
  • 3.40 Check number of topology elements - PASS (tick)
  • 3.41 Check whether the flow count is bigger than 350 - PASS (tick)
  • 3.42 Check whether all flow status are ADDED - PASS (tick)
  • 3.43 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 3.44 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 3.45 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 3.46 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 3.47 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 3.48 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 3.49 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 3.50 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 3.51 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 3.52 Checking if ONOS CLI is ready - PASS (tick)
  • 3.53 Checking ONOS nodes - PASS (tick)
  • 3.54 Check number of topology elements - PASS (tick)
  • 3.55 Check whether the flow count is bigger than 350 - PASS (tick)
  • 3.56 Check whether all flow status are ADDED - PASS (tick)
  • 3.57 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE3_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 3.58 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 3.59 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 3.60 Stopping Mininet - PASS (tick)
  • 3.61 Copying karaf logs - PASS (tick)

Case 4: High Availability tests - ONOS random failures 4x4 Leaf-spine - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Starting Mininet Topology - PASS (tick)
  • 4.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 4.14 Check whether all flow status are ADDED - PASS (tick)
  • 4.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.18 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 4.19 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 4.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 4.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 4.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Failure1 - FAIL (error)
    • IP connectivity failed
  • 4.23 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 4.24 Checking if ONOS CLI is ready - PASS (tick)
  • 4.25 Checking ONOS nodes - PASS (tick)
  • 4.26 Check number of topology elements - PASS (tick)
  • 4.27 Check whether the flow count is bigger than 350 - PASS (tick)
  • 4.28 Check whether all flow status are ADDED - PASS (tick)
  • 4.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 4.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 4.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Recovery1 - FAIL (error)
    • IP connectivity failed
  • 4.32 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 4.33 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 4.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 4.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 4.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Failure2 - FAIL (error)
    • IP connectivity failed
  • 4.37 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 4.38 Checking if ONOS CLI is ready - PASS (tick)
  • 4.39 Checking ONOS nodes - PASS (tick)
  • 4.40 Check number of topology elements - PASS (tick)
  • 4.41 Check whether the flow count is bigger than 350 - PASS (tick)
  • 4.42 Check whether all flow status are ADDED - PASS (tick)
  • 4.43 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 4.44 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 4.45 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Recovery2 - FAIL (error)
    • IP connectivity failed
  • 4.46 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 4.47 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 4.48 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 4.49 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 4.50 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Failure3 - FAIL (error)
    • IP connectivity failed
  • 4.51 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 4.52 Checking if ONOS CLI is ready - PASS (tick)
  • 4.53 Checking ONOS nodes - PASS (tick)
  • 4.54 Check number of topology elements - PASS (tick)
  • 4.55 Check whether the flow count is bigger than 350 - PASS (tick)
  • 4.56 Check whether all flow status are ADDED - PASS (tick)
  • 4.57 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE4_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 4.58 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 4.59 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4_ONOS_Recovery3 - FAIL (error)
    • IP connectivity failed
  • 4.60 Stopping Mininet - PASS (tick)
  • 4.61 Copying karaf logs - PASS (tick)

Case 5: High Availability tests - ONOS failures and Switch failures 2x2 Leaf-spine - No Result

  • No labels