Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 75 Next »

SROnosFailure at 31 Oct 2020 00:08:05

SROnosFailure

commit 7898ceda95b0e27a048c9fcee5e5c8daa332a4d4 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Jian Li [pyguni@gmail.com]
AuthorDate: Mon Oct 5 22:36:41 2020 +0900
Commit: Jian Li [pyguni@gmail.com]
CommitDate: Mon Oct 5 22:56:34 2020 +0900

Fix: make all openstack resource name optional

Case 1: ONOS Failure test with 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.19 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.20 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 1.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.23 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.24 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.25 Checking if ONOS CLI is ready - PASS (tick)
  • 1.26 Checking ONOS nodes - PASS (tick)
  • 1.27 Check number of topology elements - PASS (tick)
  • 1.28 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.29 Check whether all flow status are ADDED - PASS (tick)
  • 1.30 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.31 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS (tick)
  • 1.32 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS (tick)
  • 1.33 Stopping Mininet - PASS (tick)
  • 1.34 Copying karaf logs - PASS (tick)

Case 2: ONOS Failure test with 4x4 Leaf-spine - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.18 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 2.19 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers
  • 2.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.23 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 2.24 Checking if ONOS CLI is ready - PASS (tick)
  • 2.25 Checking ONOS nodes - PASS (tick)
  • 2.26 Check number of topology elements - PASS (tick)
  • 2.27 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.28 Check whether all flow status are ADDED - PASS (tick)
  • 2.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - PASS (tick)
  • 2.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - PASS (tick)
  • 2.32 Stopping Mininet - PASS (tick)
  • 2.33 Copying karaf logs - PASS (tick)

Case 3: ONOS Failure test with single switch - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - FAIL (error)
    • Failed to secure ssh
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Starting Mininet Topology - PASS (tick)
  • 3.13 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.14 Check whether all flow status are ADDED - PASS (tick)
  • 3.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.18 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 3.19 Check number of topology elements - PASS (tick)
  • 3.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS (tick)
  • 3.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS (tick)
  • 3.23 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 3.24 Checking if ONOS CLI is ready - PASS (tick)
  • 3.25 Checking ONOS nodes - PASS (tick)
  • 3.26 Check number of topology elements - PASS (tick)
  • 3.27 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.28 Check whether all flow status are ADDED - PASS (tick)
  • 3.29 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Recovery - PASS (tick)
  • 3.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Recovery - PASS (tick)
  • 3.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Recovery - PASS (tick)
  • 3.32 Stopping Mininet - PASS (tick)
  • 3.33 Copying karaf logs - PASS (tick)
  • No labels