Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 30 Next »

SRLinkFailure at 11 Nov 2020 02:31:58

SRLinkFailure-stratum

commit 225e2b0f3a6767211f828f8480edf314058d4cb4 (HEAD -] master, origin/master, origin/HEAD)
Author: alessio [alessio.giorgetti@gmail.com]
AuthorDate: Wed Oct 28 17:44:44 2020 +0100
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Thu Nov 5 14:48:24 2020 +0000

Extend EncapsulationConstraint to include a suggested value of the Identifier.

Case 1: Bridging and Routing Link Failure test with 2x2 Leaf-spine and 1 Onos - PASS

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Building ONOS Docker image - PASS (tick)
  • 1.6 Create Cluster Config - PASS (tick)
  • 1.7 Installing Atomix via docker containers - PASS (tick)
  • 1.8 Installing ONOS via docker containers - PASS (tick)
  • 1.9 Set up ONOS secure SSH - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Configure switches in ONOS - PASS (tick)
  • 1.17 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.18 Check whether all flow status are ADDED - PASS (tick)
  • 1.19 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - PASS (tick)
  • 1.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.22 Kill link between spine101 and leaf2 - PASS (tick)
  • 1.23 Checking topology after link down - PASS (tick)
  • 1.24 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - PASS (tick)
  • 1.25 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.26 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.27 Restore link between spine101 and leaf2 - PASS (tick)
  • 1.28 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - PASS (tick)
  • 1.29 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - PASS (tick)
  • 1.30 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - PASS (tick)
  • 1.31 Stopping Mininet - PASS (tick)
  • 1.32 Copying karaf logs - PASS (tick)

Case 2: Bridging and Routing Link Failure test with 4x4 Leaf-spine and 1 Onos - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Building ONOS Docker image - PASS (tick)
  • 2.5 Create Cluster Config - PASS (tick)
  • 2.6 Installing Atomix via docker containers - PASS (tick)
  • 2.7 Installing ONOS via docker containers - PASS (tick)
  • 2.8 Set up ONOS secure SSH - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Set logging levels - PASS (tick)
  • 2.13 Set ONOS configurations - PASS (tick)
  • 2.14 Starting Mininet Topology - PASS (tick)
  • 2.15 Configure switches in ONOS - PASS (tick)
  • 2.16 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.17 Check whether all flow status are ADDED - PASS (tick)
  • 2.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.21 Kill link between spine101 and leaf2 - PASS (tick)
  • 2.22 Checking topology after link down - FAIL (error)
    • Topology after link down is incorrect
  • 2.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.24 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.25 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.26 Restore link between spine101 and leaf2 - FAIL (error)
    • Failed to bring link up
  • 2.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Recovery - PASS (tick)
  • 2.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Recovery - PASS (tick)
  • 2.30 Stopping Mininet - PASS (tick)
  • 2.31 Copying karaf logs - PASS (tick)

Case 4: Bridging and Routing Link Failure test with 2x2 Leaf-spine and 3 Onos - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Building ONOS Docker image - PASS (tick)
  • 4.5 Create Cluster Config - PASS (tick)
  • 4.6 Installing Atomix via docker containers - PASS (tick)
  • 4.7 Installing ONOS via docker containers - PASS (tick)
  • 4.8 Set up ONOS secure SSH - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Set logging levels - PASS (tick)
  • 4.13 Set ONOS configurations - PASS (tick)
  • 4.14 Starting Mininet Topology - PASS (tick)
  • 4.15 Configure switches in ONOS - PASS (tick)
  • 4.16 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.17 Check whether all flow status are ADDED - PASS (tick)
  • 4.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS (tick)
  • 4.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS (tick)
  • 4.21 Kill link between spine101 and leaf2 - PASS (tick)
  • 4.22 Checking topology after link down - PASS (tick)
  • 4.23 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 4.24 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS (tick)
  • 4.25 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS (tick)
  • 4.26 Restore link between spine101 and leaf2 - PASS (tick)
  • 4.27 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 4.28 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Recovery - PASS (tick)
  • 4.29 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Recovery - PASS (tick)
  • 4.30 Stopping Mininet - PASS (tick)
  • 4.31 Copying karaf logs - PASS (tick)

Case 5: Bridging and Routing Link Failure test with 4x4 Leaf-spine and 3 Onos - FAIL

  • No labels