Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 70 Next »

SROnosFailure at 03 May 2021 19:54:18

SROnosFailure-stratum

commit 219dd8fedf54e33da8df7bcb4e755724a7637650 (HEAD -] master, origin/master, origin/HEAD)
Author: pierventre [pier@opennetworking.org]
AuthorDate: Wed Apr 21 12:57:47 2021 +0200
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Fri Apr 30 04:33:42 2021 +0000

[AETHER-1550] Add additional trace logs in P4RT SB

Case 1: ONOS Failure test with 2x2 leaf-spine topology - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Building ONOS Docker image - PASS (tick)
  • 1.6 Create Cluster Config - PASS (tick)
  • 1.7 Installing Atomix via docker containers - PASS (tick)
  • 1.8 Installing ONOS via docker containers - PASS (tick)
  • 1.9 Set up ONOS secure SSH - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Configure switches in ONOS - PASS (tick)
  • 1.17 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 4 devices (4 expected) and 0 links (8 expected) and 3 controllers (3 expected) and 4 SCCs (1 expected)
  • 1.18 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 116
  • 1.19 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.20 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.21 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.22 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.23 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 1.24 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 4 devices (4 expected) and 0 links (8 expected) and 2 controllers (2 expected) and 4 SCCs (1 expected)
  • 1.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.28 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 1.29 Checking if ONOS CLI is ready - PASS (tick)
  • 1.30 Checking ONOS nodes - PASS (tick)
  • 1.31 Check number of topology elements - PASS (tick)
  • 1.32 Check whether the flow count is >= 116 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 116
  • 1.33 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 1.34 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.35 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.36 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Recovery - FAIL (error)
    • IP connectivity failed
  • 1.37 Check number of topology elements - FAIL (error)
    • Unexpected number of links, switches, and/or controllers: The number of links, switches, nodes, and SCCs does not match what was expected
    • ONOS sees 4 devices (4 expected) and 0 links (8 expected) and 3 controllers (3 expected) and 4 SCCs (1 expected)
  • 1.38 Stopping Mininet - PASS (tick)
  • 1.39 Copying karaf logs - PASS (tick)

Case 2: ONOS Failure test with 4x4 dual-homed leaf-spine topology - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Building ONOS Docker image - PASS (tick)
  • 2.5 Create Cluster Config - PASS (tick)
  • 2.6 Installing Atomix via docker containers - PASS (tick)
  • 2.7 Installing ONOS via docker containers - PASS (tick)
  • 2.8 Set up ONOS secure SSH - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Set logging levels - PASS (tick)
  • 2.13 Set ONOS configurations - PASS (tick)
  • 2.14 Stopping Mininet - PASS (tick)
  • 2.15 Copying karaf logs - PASS (tick)
    • Skipping the rest of this case. 'mininetArgs'

Case 3: ONOS Failure test with single ToR - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Building ONOS Docker image - PASS (tick)
  • 3.5 Create Cluster Config - PASS (tick)
  • 3.6 Installing Atomix via docker containers - PASS (tick)
  • 3.7 Installing ONOS via docker containers - PASS (tick)
  • 3.8 Set up ONOS secure SSH - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Set logging levels - PASS (tick)
  • 3.13 Set ONOS configurations - PASS (tick)
  • 3.14 Starting Mininet Topology - PASS (tick)
  • 3.15 Configure switches in ONOS - PASS (tick)
  • 3.16 Check number of topology elements - PASS (tick)
  • 3.17 Check whether the flow count is >= 15 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 15
  • 3.18 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 3.19 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.20 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.21 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.22 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.23 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 3.24 Check number of topology elements - PASS (tick)
  • 3.25 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.28 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.29 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 3.30 Checking if ONOS CLI is ready - PASS (tick)
  • 3.31 Checking ONOS nodes - PASS (tick)
  • 3.32 Check number of topology elements - PASS (tick)
  • 3.33 Check whether the flow count is >= 15 - FAIL (error)
    • Flow count looks wrong; found 0, expecting at least 15
  • 3.34 Check whether all flow status are ADDED - FAIL (error)
    • Flow status is wrong!
  • 3.35 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Recovery - PASS (tick)
  • 3.36 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 3.37 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 3.38 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 3.39 Check number of topology elements - PASS (tick)
  • 3.40 Stopping Mininet - PASS (tick)
  • 3.41 Copying karaf logs - PASS (tick)
  • No labels