HAsingleInstanceRestart at 10 Aug 2018 23:30:30
commit 4867af2f9c0f2fcb01850fe682b285c2aa1d50da (HEAD -] master, origin/master, origin/HEAD)
Author: Ray Milkey [ray@opennetworking.org]
AuthorDate: Fri Aug 10 16:52:28 2018 -0700
Commit: Ray Milkey [ray@opennetworking.org]
CommitDate: Fri Aug 10 16:53:10 2018 -0700
Revert "Tagging 1.14.0-b1"
--
This reverts commit 78ce40093ac008fd6d169ab83d2d5961f91f6e31.
Change-Id: I8482f550c30f75d65333f6be9c9115a930abc56f
Case 1: Constructing test variables and building ONOS package - FAIL
For loading from params file, and pull and build the latest ONOS package
- 1.1 Constructing test variables - PASS
- 1.2 Apply cell to environment - PASS
- 1.3 Uninstalling Atomix - PASS
- 1.4 Uninstalling ONOS package - PASS
- 1.5 Apply cell to environment - PASS
- 1.6 Creating ONOS package - PASS
- 1.7 Installing Atomix - PASS
- 1.8 Installing ONOS package - PASS
- 1.9 Set up ONOS secure SSH - PASS
- 1.10 Checking ONOS service - PASS
- 1.11 Starting ONOS CLI sessions - PASS
- 1.12 Checking ONOS nodes - PASS
- 1.13 Checking ONOS applications - FAIL
- Not all ONOS apps are activated
- 1.14 Checking ONOS nodes - PASS
- 1.15 Activate apps defined in the params file - No Result
- 1.16 Set ONOS configurations - PASS
- 1.17 Check app ids - PASS
- 1.18 Set logging levels - PASS
Case 102: Starting Mininet Topology - FAIL
- 102.1 Pushing Network config - PASS
- 102.2 Check Network config - FAIL
- Net Cfg not correctly set
- 102.3 Start Mininet topology - PASS
Case 8: Compare ONOS Topology view to Mininet topology - PASS
Compare topology objects between Mininet and ONOS
- 8.1 Comparing ONOS topology to MN topology - PASS
- 8.2 Checking ONOS nodes - PASS
Case 104: Check connectivity - FAIL
- 104.1 Ping between all hosts - FAIL
- Failed to ping between all hosts
Case 8: Compare ONOS Topology view to Mininet topology - PASS
Compare topology objects between Mininet and ONOS
- 8.1 Comparing ONOS topology to MN topology - PASS
- 8.2 Checking ONOS nodes - PASS
Case 5: Setting up and gathering data for current state - FAIL
- 5.1 Check that each switch has a master - PASS
- 5.2 Get the Mastership of each switch from each controller - No Result
- 5.3 Read device roles from ONOS - PASS
- 5.4 Check for consistency in roles from each controller - PASS
- 5.5 Get the intents from each controller - PASS
- 5.6 Check for consistency in Intents from each controller - PASS
- 5.7 Get the flows from each controller - PASS
- 5.8 Check for consistency in Flows from each controller - PASS
- 5.9 Get the OF Table entries - No Result
- 5.10 Start continuous pings - No Result
- 5.11 Collecting topology information from ONOS - No Result
- 5.12 Host view is consistent across ONOS nodes - FAIL
- ONOS nodes have different views of hosts
- 5.13 Each host has an IP address - PASS
- 5.14 Cluster view is consistent across ONOS nodes - PASS
- 5.15 Cluster view correct across ONOS nodes - PASS
- 5.16 Comparing ONOS topology to MN - FAIL
- ONOS1 hosts don't match Mininet
- 5.17 Device information is correct - PASS
- 5.18 Links are correct - PASS
- 5.19 Hosts are correct - FAIL
- Hosts are incorrect