SRDynamicConf at 18 Dec 2018 02:33:12
commit 20f71e063b095e572b2b0b1cd6797d59feb4531d (HEAD -] onos-1.14, origin/onos-1.14)
Author: Ray Milkey [ray@opennetworking.org]
AuthorDate: Mon Dec 17 09:13:24 2018 -0800
Commit: Ray Milkey [ray@opennetworking.org]
CommitDate: Mon Dec 17 09:17:50 2018 -0800
bump up required version of bazel to 0.19
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 13.1 Constructing test variables - PASS
- 13.2 Apply cell to environment - PASS
- 13.3 Uninstalling Atomix - PASS
- 13.4 Uninstalling ONOS package - PASS
- 13.5 Creating ONOS package - PASS
- 13.6 Installing Atomix - PASS
- 13.7 Installing ONOS package - PASS
- 13.8 Set up ONOS secure SSH - FAIL
- Failed to secure ssh
- 13.9 Checking ONOS service - PASS
- 13.10 Starting ONOS CLI sessions - PASS
- 13.11 Checking ONOS nodes - PASS
- 13.12 Checking ONOS applications - PASS
- 13.13 Starting Mininet Topology - PASS
- 13.14 Check whether the flow count is bigger than 104 - PASS
- 13.15 Check whether all flow status are ADDED - PASS
- 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS
- 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 13.19 Check whether the flow count is bigger than 104 - PASS
- 13.20 Check whether all flow status are ADDED - PASS
- 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS
- 13.22 Stopping Mininet - PASS
- 13.23 Copying karaf logs - PASS
Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - FAIL
- Failed to secure ssh
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - PASS
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS
Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling Atomix - PASS
- 33.3 Uninstalling ONOS package - PASS
- 33.4 Installing Atomix - PASS
- 33.5 Installing ONOS package - PASS
- 33.6 Set up ONOS secure SSH - PASS
- 33.7 Checking ONOS service - PASS
- 33.8 Starting ONOS CLI sessions - PASS
- 33.9 Checking ONOS nodes - PASS
- 33.10 Checking ONOS applications - PASS
- 33.11 Starting Mininet Topology - PASS
- 33.12 Check whether the flow count is bigger than 104 - FAIL
- Flow count looks wrong: False
- 33.13 Check whether all flow status are ADDED - PASS
- 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - FAIL
- IP connectivity failed
- 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - FAIL
- IP connectivity failed
- 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL
- Flow count looks wrong.
- 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL
- Flow count looks wrong.
- 33.18 Check whether the flow count is bigger than 104 - FAIL
- Flow count looks wrong: False
- 33.19 Check whether all flow status are ADDED - PASS
- 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - FAIL
- IP connectivity failed
- 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS
- 33.22 Stopping Mininet - PASS
- 33.23 Copying karaf logs - PASS
Case 43: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 43.1 Apply cell to environment - PASS
- 43.2 Uninstalling Atomix - PASS
- 43.3 Uninstalling ONOS package - PASS
- 43.4 Installing Atomix - PASS
- 43.5 Installing ONOS package - PASS
- 43.6 Set up ONOS secure SSH - FAIL
- Failed to secure ssh
- 43.7 Checking ONOS service - PASS
- 43.8 Starting ONOS CLI sessions - PASS
- 43.9 Checking ONOS nodes - PASS
- 43.10 Checking ONOS applications - PASS
- 43.11 Starting Mininet Topology - PASS
- 43.12 Check whether the flow count is bigger than 104 - PASS
- 43.13 Check whether all flow status are ADDED - PASS
- 43.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS
- 43.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS
- 43.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 43.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 43.18 Check whether the flow count is bigger than 104 - PASS
- 43.19 Check whether all flow status are ADDED - PASS
- 43.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS
- 43.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS
- 43.22 Stopping Mininet - PASS
- 43.23 Copying karaf logs - PASS
Case 53: Changing port configuration from untagged 10 to tagged 20 with native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 53.1 Apply cell to environment - PASS
- 53.2 Uninstalling Atomix - PASS
- 53.3 Uninstalling ONOS package - PASS
- 53.4 Installing Atomix - PASS
- 53.5 Installing ONOS package - PASS
- 53.6 Set up ONOS secure SSH - FAIL
- Failed to secure ssh
- 53.7 Checking ONOS service - PASS
- 53.8 Starting ONOS CLI sessions - PASS
- 53.9 Checking ONOS nodes - PASS
- 53.10 Checking ONOS applications - PASS
- 53.11 Starting Mininet Topology - PASS
- 53.12 Check whether the flow count is bigger than 104 - PASS
- 53.13 Check whether all flow status are ADDED - PASS
- 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS
- 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS
- 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 53.18 Check whether the flow count is bigger than 104 - PASS
- 53.19 Check whether all flow status are ADDED - PASS
- 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS
- 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS
- 53.22 Stopping Mininet - PASS
- 53.23 Copying karaf logs - PASS
Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 63.1 Apply cell to environment - PASS
- 63.2 Uninstalling Atomix - PASS
- 63.3 Uninstalling ONOS package - PASS
- 63.4 Installing Atomix - PASS
- 63.5 Installing ONOS package - PASS
- 63.6 Set up ONOS secure SSH - FAIL
- Failed to secure ssh
- 63.7 Checking ONOS service - PASS
- 63.8 Starting ONOS CLI sessions - PASS
- 63.9 Checking ONOS nodes - PASS
- 63.10 Checking ONOS applications - PASS
- 63.11 Starting Mininet Topology - PASS
- 63.12 Check whether the flow count is bigger than 104 - PASS
- 63.13 Check whether all flow status are ADDED - PASS
- 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - PASS
- 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - PASS
- 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 63.18 Check whether the flow count is bigger than 104 - PASS
- 63.19 Check whether all flow status are ADDED - PASS
- 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS
- 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS
- 63.22 Stopping Mininet - PASS
- 63.23 Copying karaf logs - PASS