Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 20 Next »

SRDynamicConf at 20 Sep 2019 11:02:16

SRDynamicConf

commit cb787514974d13ccce4214997ba3e6c1c630e860 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Harshada Chaundkar [Harshada_Chaundkar@comcast.com]
AuthorDate: Mon Aug 5 15:33:30 2019 +0000
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Tue Sep 17 00:53:40 2019 +0000

Adding ACL flow for Table 60 for Ipv6
--
(cherry picked from commit 77958a5941bfa989f54858dee5515e137676e3db)

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Starting Mininet Topology - PASS (tick)
  • 13.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.15 Check whether all flow status are ADDED - PASS (tick)
  • 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.19 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.20 Check whether all flow status are ADDED - PASS (tick)
  • 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.22 Stopping Mininet - PASS (tick)
  • 13.23 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • No labels