SRDynamicConf at 22 Oct 2019 12:26:49
commit c1184d777cf02e997262fc675b7ca4a932f54bd4 (HEAD -] onos-2.2, origin/onos-2.2)
Author: Chinmaya Agarwal [chinmaya.agarwal@hsc.com]
AuthorDate: Wed Oct 9 16:53:22 2019 +0530
Commit: Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Wed Oct 16 10:45:38 2019 +0000
Fix for Bug 8005. Parsing Sub Tlv for multiple neighbors
--
(cherry picked from commit 8bfea5ec60caa14aa61b4efba1758f0394be8a4e)
Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
- 13.1 Constructing test variables - PASS
- 13.2 Apply cell to environment - PASS
- 13.3 Uninstalling Atomix - PASS
- 13.4 Uninstalling ONOS package - PASS
- 13.5 Creating ONOS package - PASS
- 13.6 Installing Atomix - PASS
- 13.7 Installing ONOS package - PASS
- 13.8 Set up ONOS secure SSH - PASS
- 13.9 Checking ONOS service - PASS
- 13.10 Starting ONOS CLI sessions - PASS
- 13.11 Checking ONOS nodes - PASS
- 13.12 Checking ONOS applications - PASS
- 13.13 Starting Mininet Topology - PASS
- 13.14 Check whether the flow count is bigger than 104 - PASS
- 13.15 Check whether all flow status are ADDED - PASS
- 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS
- 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 13.19 Check whether the flow count is bigger than 104 - PASS
- 13.20 Check whether all flow status are ADDED - PASS
- 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS
- 13.22 Stopping Mininet - PASS
- 13.23 Copying karaf logs - PASS
Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL
- 23.1 Apply cell to environment - PASS
- 23.2 Uninstalling Atomix - PASS
- 23.3 Uninstalling ONOS package - PASS
- 23.4 Installing Atomix - PASS
- 23.5 Installing ONOS package - PASS
- 23.6 Set up ONOS secure SSH - PASS
- 23.7 Checking ONOS service - PASS
- 23.8 Starting ONOS CLI sessions - PASS
- 23.9 Checking ONOS nodes - PASS
- 23.10 Checking ONOS applications - PASS
- 23.11 Starting Mininet Topology - PASS
- 23.12 Check whether the flow count is bigger than 106 - PASS
- 23.13 Check whether all flow status are ADDED - PASS
- 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS
- 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS
- 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS
- 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS
- 23.18 Check whether the flow count is bigger than 106 - PASS
- 23.19 Check whether all flow status are ADDED - FAIL
- Flow status is wrong!
- 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS
- 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS
- 23.22 Stopping Mininet - PASS
- 23.23 Copying karaf logs - PASS
Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances - PASS
- 33.1 Apply cell to environment - PASS
- 33.2 Uninstalling Atomix - PASS
- 33.3 Uninstalling ONOS package - PASS
- 33.4 Installing Atomix - PASS
- 33.5 Installing ONOS package - PASS
- 33.6 Set up ONOS secure SSH - PASS
- 33.7 Checking ONOS service - PASS
- 33.8 Starting ONOS CLI sessions - PASS
- 33.9 Checking ONOS nodes - PASS
- 33.10 Checking ONOS applications - PASS
- 33.11 Starting Mininet Topology - PASS
- 33.12 Check whether the flow count is bigger than 104 - PASS
- 33.13 Check whether all flow status are ADDED - PASS
- 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS
- 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS
- 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS
- 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS
- 33.18 Check whether the flow count is bigger than 104 - PASS
- 33.19 Check whether all flow status are ADDED - PASS
- 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS
- 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS
- 33.22 Stopping Mininet - PASS
- 33.23 Copying karaf logs - PASS