FUNCgroup at 12 Feb 2020 02:11:04

<img src="https://jenkins.onosproject.org/view/QA/job/postjob-VM/lastSuccessfulBuild/artifact/FUNCgroup_master_20-builds_graph.jpg", alt="FUNCgroup", style="width:525px;height:350px;border:0">
commit 811ea2b63db393d2fc8bdccb792023e17d342502 (HEAD -] master, origin/master, origin/HEAD)
Author: Thomas Vachuska [tom@opennetworking.org]
AuthorDate: Tue Feb 11 10:20:10 2020 -0800
Commit: Thomas Vachuska [tom@opennetworking.org]
CommitDate: Tue Feb 11 19:49:53 2020 +0000

Add ability to administratively remove ports of an offline device.

Case 1: Pull onos branch and build onos on Teststation. - PASS

For loading from params file, and pull and build the latest ONOS package

Case 2: Starting up 1 node(s) ONOS cluster - PASS

Set up ONOS with 1 node(s) ONOS cluster

Case 3: Compare ONOS Topology view to Mininet topology - PASS

Compare topology elements between Mininet and ONOS

Case 5: Verify Group of type All are successfully Added - FAIL

Install a Group of type ALL Verify the Group is Added Add a flow using the group Send a packet that verifies the action bucket of the group

Case 6: Delete the Group and Flow added through Rest api - PASS

Case 7: Verify Group of type INDIRECT are successfully Added - PASS

Install a Group of type INDIRECT Verify the Group is Added Add a flow using the group Send a packet that verifies the action bucket of the group

Case 6: Delete the Group and Flow added through Rest api - PASS

Case 10: Stop Mininet and Scapy - PASS

Stopping the current mininet topology to start up fresh

Case 100: - PASS