Due to a ransomware attack, the wiki was reverted to a July 2022 version. . We apologize for the lack of a more recent valid backup.
SRSanity at 02 Jul 2021 19:31:16
commit 375942a31f14dd27db811abb3be1d1c57c50f312 (HEAD -] onos-2.2, origin/onos-2.2)
Author: pierventre [pier@opennetworking.org]
AuthorDate: Tue Jun 29 14:04:42 2021 +0200
Commit: pierventre [pier@opennetworking.org]
CommitDate: Thu Jul 1 19:28:01 2021 +0200
[SDFAB-271] Change the default max inbound metadata size for grpc channels
Case 1: Bridging and Routing sanity test with 2x2 Leaf-spine and 1 Onos - PASS
- 1.1 Constructing test variables - PASS
- 1.2 Apply cell to environment - PASS
- 1.3 Uninstalling Atomix - PASS
- 1.4 Uninstalling ONOS package - PASS
- 1.5 Creating ONOS package - PASS
- 1.6 Installing Atomix - PASS
- 1.7 Installing ONOS package - PASS
- 1.8 Set up ONOS secure SSH - PASS
- 1.9 Checking ONOS service - PASS
- 1.10 Starting ONOS CLI sessions - PASS
- 1.11 Checking ONOS nodes - PASS
- 1.12 Checking ONOS applications - PASS
- 1.13 Set logging levels - PASS
- 1.14 Set ONOS configurations - PASS
- 1.15 Starting Mininet Topology - PASS
- 1.16 Check whether the flow count is >= 116 - PASS
- 1.17 Check whether all flow status are ADDED - PASS
- 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - PASS
- 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS
- 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS
- 1.21 Stopping Mininet - PASS
- 1.22 Copying karaf logs - PASS
Case 2: Bridging and Routing sanity test with 4x4 Leaf-spine and 1 Onos - FAIL
- 2.1 Apply cell to environment - PASS
- 2.2 Uninstalling Atomix - PASS
- 2.3 Uninstalling ONOS package - PASS
- 2.4 Creating ONOS package - PASS
- 2.5 Installing Atomix - PASS
- 2.6 Installing ONOS package - PASS
- 2.7 Set up ONOS secure SSH - PASS
- 2.8 Checking ONOS service - PASS
- 2.9 Starting ONOS CLI sessions - PASS
- 2.10 Checking ONOS nodes - PASS
- 2.11 Checking ONOS applications - PASS
- 2.12 Set logging levels - PASS
- 2.13 Set ONOS configurations - PASS
- 2.14 Starting Mininet Topology - PASS
- 2.15 Check whether the flow count is >= 350 - PASS
- 2.16 Check whether all flow status are ADDED - PASS
- 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL
- IP connectivity failed
- 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS
- 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS
- 2.20 Stopping Mininet - PASS
- 2.21 Copying karaf logs - PASS
Case 3: Bridging and Routing sanity test with single switch and 1 Onos - PASS
- 3.1 Apply cell to environment - PASS
- 3.2 Uninstalling Atomix - PASS
- 3.3 Uninstalling ONOS package - PASS
- 3.4 Creating ONOS package - PASS
- 3.5 Installing Atomix - PASS
- 3.6 Installing ONOS package - PASS
- 3.7 Set up ONOS secure SSH - PASS
- 3.8 Checking ONOS service - PASS
- 3.9 Starting ONOS CLI sessions - PASS
- 3.10 Checking ONOS nodes - PASS
- 3.11 Checking ONOS applications - PASS
- 3.12 Set logging levels - PASS
- 3.13 Set ONOS configurations - PASS
- 3.14 Starting Mininet Topology - PASS
- 3.15 Check whether the flow count is >= 15 - PASS
- 3.16 Check whether all flow status are ADDED - PASS
- 3.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS
- 3.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS
- 3.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS
- 3.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE3 - PASS
- 3.21 Stopping Mininet - PASS
- 3.22 Copying karaf logs - PASS
Case 4: Bridging and Routing sanity test with 2x2 Leaf-spine and 3 Onos - FAIL
- 4.1 Apply cell to environment - PASS
- 4.2 Uninstalling Atomix - PASS
- 4.3 Uninstalling ONOS package - PASS
- 4.4 Creating ONOS package - PASS
- 4.5 Installing Atomix - PASS
- 4.6 Installing ONOS package - PASS
- 4.7 Set up ONOS secure SSH - PASS
- 4.8 Checking ONOS service - PASS
- 4.9 Starting ONOS CLI sessions - PASS
- 4.10 Checking ONOS nodes - PASS
- 4.11 Checking ONOS applications - PASS
- 4.12 Set logging levels - PASS
- 4.13 Set ONOS configurations - PASS
- 4.14 Starting Mininet Topology - PASS
- 4.15 Check whether the flow count is >= 116 - PASS
- 4.16 Check whether all flow status are ADDED - PASS
- 4.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL
- IP connectivity failed
- 4.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - PASS
- 4.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - PASS
- 4.20 Stopping Mininet - PASS
- 4.21 Copying karaf logs - PASS
Case 5: Bridging and Routing sanity test with 4x4 Leaf-spine and 3 Onos - FAIL
- 5.1 Apply cell to environment - PASS
- 5.2 Uninstalling Atomix - PASS
- 5.3 Uninstalling ONOS package - PASS
- 5.4 Creating ONOS package - PASS
- 5.5 Installing Atomix - PASS
- 5.6 Installing ONOS package - PASS
- 5.7 Set up ONOS secure SSH - PASS
- 5.8 Checking ONOS service - PASS
- 5.9 Starting ONOS CLI sessions - PASS
- 5.10 Checking ONOS nodes - PASS
- 5.11 Checking ONOS applications - PASS
- 5.12 Set logging levels - PASS
- 5.13 Set ONOS configurations - PASS
- 5.14 Starting Mininet Topology - PASS
- 5.15 Check whether the flow count is >= 350 - PASS
- 5.16 Check whether all flow status are ADDED - PASS
- 5.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL
- IP connectivity failed
- 5.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - PASS
- 5.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - PASS
- 5.20 Stopping Mininet - PASS
- 5.21 Copying karaf logs - PASS
Case 6: Bridging and Routing sanity test with single switch and 3 Onos - PASS
- 6.1 Apply cell to environment - PASS
- 6.2 Uninstalling Atomix - PASS
- 6.3 Uninstalling ONOS package - PASS
- 6.4 Creating ONOS package - PASS
- 6.5 Installing Atomix - PASS
- 6.6 Installing ONOS package - PASS
- 6.7 Set up ONOS secure SSH - PASS
- 6.8 Checking ONOS service - PASS
- 6.9 Starting ONOS CLI sessions - PASS
- 6.10 Checking ONOS nodes - PASS
- 6.11 Checking ONOS applications - PASS
- 6.12 Set logging levels - PASS
- 6.13 Set ONOS configurations - PASS
- 6.14 Starting Mininet Topology - PASS
- 6.15 Check whether the flow count is >= 15 - PASS
- 6.16 Check whether all flow status are ADDED - PASS
- 6.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS
- 6.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - PASS
- 6.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - PASS
- 6.20 Verify full connectivity for [u'olt1', u'vsg1'] with tag CASE6 - PASS
- 6.21 Stopping Mininet - PASS
- 6.22 Copying karaf logs - PASS