SRSanity at 31 Jan 2020 19:31:17

SRSanity

commit 5e8f07e1d2597767353f44804d9ea0058c20341d (HEAD -] onos-2.2, origin/onos-2.2)
Author: ONOS Jenkins User [jenkins@onlab.us]
AuthorDate: Wed Jan 29 02:25:41 2020 +0000
Commit: ONOS Jenkins User [jenkins@onlab.us]
CommitDate: Wed Jan 29 02:25:41 2020 +0000

Starting snapshot 2.2.1-SNAPSHOT

Case 1: Bridging and Routing sanity test with 2x2 Leaf-spine and 1 Onos - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Starting Mininet Topology - PASS (tick)
  • 1.14 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.15 Check whether all flow status are ADDED - PASS (tick)
  • 1.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.17 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.18 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.19 Stopping Mininet - PASS (tick)
  • 1.20 Copying karaf logs - PASS (tick)

Case 2: Bridging and Routing sanity test with 4x4 Leaf-spine and 1 Onos - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling Atomix - PASS (tick)
  • 2.3 Uninstalling ONOS package - PASS (tick)
  • 2.4 Creating ONOS package - PASS (tick)
  • 2.5 Installing Atomix - PASS (tick)
  • 2.6 Installing ONOS package - PASS (tick)
  • 2.7 Set up ONOS secure SSH - PASS (tick)
  • 2.8 Checking ONOS service - PASS (tick)
  • 2.9 Starting ONOS CLI sessions - PASS (tick)
  • 2.10 Checking ONOS nodes - PASS (tick)
  • 2.11 Checking ONOS applications - PASS (tick)
  • 2.12 Starting Mininet Topology - PASS (tick)
  • 2.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.14 Check whether all flow status are ADDED - PASS (tick)
  • 2.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.18 Stopping Mininet - PASS (tick)
  • 2.19 Copying karaf logs - PASS (tick)

Case 3: Bridging and Routing sanity test with single switch and 1 Onos - FAIL

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling Atomix - PASS (tick)
  • 3.3 Uninstalling ONOS package - PASS (tick)
  • 3.4 Creating ONOS package - PASS (tick)
  • 3.5 Installing Atomix - PASS (tick)
  • 3.6 Installing ONOS package - PASS (tick)
  • 3.7 Set up ONOS secure SSH - PASS (tick)
  • 3.8 Checking ONOS service - PASS (tick)
  • 3.9 Starting ONOS CLI sessions - PASS (tick)
  • 3.10 Checking ONOS nodes - PASS (tick)
  • 3.11 Checking ONOS applications - PASS (tick)
  • 3.12 Starting Mininet Topology - PASS (tick)
  • 3.13 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.14 Check whether all flow status are ADDED - PASS (tick)
  • 3.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.18 Stopping Mininet - PASS (tick)
  • 3.19 Copying karaf logs - PASS (tick)

Case 4: Bridging and Routing sanity test with 2x2 Leaf-spine and 3 Onos - FAIL

  • 4.1 Apply cell to environment - PASS (tick)
  • 4.2 Uninstalling Atomix - PASS (tick)
  • 4.3 Uninstalling ONOS package - PASS (tick)
  • 4.4 Creating ONOS package - PASS (tick)
  • 4.5 Installing Atomix - PASS (tick)
  • 4.6 Installing ONOS package - PASS (tick)
  • 4.7 Set up ONOS secure SSH - PASS (tick)
  • 4.8 Checking ONOS service - PASS (tick)
  • 4.9 Starting ONOS CLI sessions - PASS (tick)
  • 4.10 Checking ONOS nodes - PASS (tick)
  • 4.11 Checking ONOS applications - PASS (tick)
  • 4.12 Starting Mininet Topology - PASS (tick)
  • 4.13 Check whether the flow count is bigger than 116 - PASS (tick)
  • 4.14 Check whether all flow status are ADDED - PASS (tick)
  • 4.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE4 - FAIL (error)
    • IP connectivity failed
  • 4.18 Stopping Mininet - PASS (tick)
  • 4.19 Copying karaf logs - PASS (tick)

Case 5: Bridging and Routing sanity test with 4x4 Leaf-spine and 3 Onos - FAIL

  • 5.1 Apply cell to environment - PASS (tick)
  • 5.2 Uninstalling Atomix - PASS (tick)
  • 5.3 Uninstalling ONOS package - PASS (tick)
  • 5.4 Creating ONOS package - PASS (tick)
  • 5.5 Installing Atomix - PASS (tick)
  • 5.6 Installing ONOS package - PASS (tick)
  • 5.7 Set up ONOS secure SSH - PASS (tick)
  • 5.8 Checking ONOS service - PASS (tick)
  • 5.9 Starting ONOS CLI sessions - PASS (tick)
  • 5.10 Checking ONOS nodes - PASS (tick)
  • 5.11 Checking ONOS applications - PASS (tick)
  • 5.12 Starting Mininet Topology - PASS (tick)
  • 5.13 Check whether the flow count is bigger than 350 - PASS (tick)
  • 5.14 Check whether all flow status are ADDED - PASS (tick)
  • 5.15 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE5 - FAIL (error)
    • IP connectivity failed
  • 5.18 Stopping Mininet - PASS (tick)
  • 5.19 Copying karaf logs - PASS (tick)

Case 6: Bridging and Routing sanity test with single switch and 3 Onos - FAIL

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Creating ONOS package - PASS (tick)
  • 6.5 Installing Atomix - PASS (tick)
  • 6.6 Installing ONOS package - PASS (tick)
  • 6.7 Set up ONOS secure SSH - PASS (tick)
  • 6.8 Checking ONOS service - PASS (tick)
  • 6.9 Starting ONOS CLI sessions - PASS (tick)
  • 6.10 Checking ONOS nodes - PASS (tick)
  • 6.11 Checking ONOS applications - PASS (tick)
  • 6.12 Starting Mininet Topology - PASS (tick)
  • 6.13 Check whether the flow count is bigger than 15 - PASS (tick)
  • 6.14 Check whether all flow status are ADDED - PASS (tick)
  • 6.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.16 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.17 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE6 - FAIL (error)
    • IP connectivity failed
  • 6.18 Stopping Mininet - PASS (tick)
  • 6.19 Copying karaf logs - PASS (tick)
  • No labels