Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 13 Next »

SRClusterRestart at 13 Aug 2017 02:23:20

commit 52f5828004e9c59774a94542e74af7dcc18d9771 (HEAD, origin/onos-1.9, onos-1.9)
Author: Ray Milkey [ray@onlab.us]
AuthorDate: Fri Jun 23 12:46:32 2017 -0700
Commit: Ray Milkey [ray@onlab.us]
CommitDate: Fri Jun 23 12:46:32 2017 -0700

Starting snapshot 1.9.3-SNAPSHOT

Case 1: Copy karaf logs - FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 1.1 Constructing test variables - No Result (warning)
  • 1.2 Constructing test variables - PASS (tick)
  • 1.3 Apply cell to environment - PASS (tick)
  • 1.4 Creating ONOS package - PASS (tick)
  • 1.5 Installing ONOS package - PASS (tick)
  • 1.6 Set up ONOS secure SSH - PASS (tick)
  • 1.7 Checking ONOS service - PASS (tick)
  • 1.8 Checking if ONOS CLI is ready - PASS (tick)
  • 1.9 Starting Mininet Topology - PASS (tick)
  • 1.10 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong: False
  • 1.11 Check whether all flow status are ADDED - PASS (tick)
  • 1.12 Connectivity for [u'h1', u'h2', u'h3', u'h4'] CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.13 Connectivity for [u'olt10', u'vsg10'] CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.14 Connectivity for [u'olt5', u'vsg5'] CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.15 Killing ONOS instance - PASS (tick)
  • 1.16 Connectivity for [u'h1', u'h2', u'h3', u'h4'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.17 Connectivity for [u'olt10', u'vsg10'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.18 Connectivity for [u'olt5', u'vsg5'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.19 Recovering ONOS instance - PASS (tick)
  • 1.20 Checking if ONOS CLI is ready - PASS (tick)
  • 1.21 Checking if ONOS CLI is ready - PASS (tick)
  • 1.22 Checking if ONOS CLI is ready - PASS (tick)
  • 1.23 Checking ONOS nodes - PASS (tick)
  • 1.24 Check whether the flow count is bigger than 116 - FAIL (error)
    • Flow count looks wrong: False
  • 1.25 Check whether all flow status are ADDED - PASS (tick)
  • 1.26 Connectivity for [u'h1', u'h2', u'h3', u'h4'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.27 Connectivity for [u'olt10', u'vsg10'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.28 Connectivity for [u'olt5', u'vsg5'] CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.29 Stopping Mininet - PASS (tick)
  • 1.30 Copying karaf logs - PASS (tick)

Case 2: Copy karaf logs - FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Creating ONOS package - PASS (tick)
  • 2.3 Installing ONOS package - PASS (tick)
  • 2.4 Set up ONOS secure SSH - PASS (tick)
  • 2.5 Checking ONOS service - PASS (tick)
  • 2.6 Checking if ONOS CLI is ready - PASS (tick)
  • 2.7 Starting Mininet Topology - PASS (tick)
  • 2.8 Check whether the flow count is bigger than 350 - FAIL (error)
    • Flow count looks wrong: False
  • 2.9 Check whether all flow status are ADDED - PASS (tick)
  • 2.10 Connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.11 Connectivity for [u'olt10', u'vsg10'] CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.12 Connectivity for [u'olt5', u'vsg5'] CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.13 Killing ONOS instance - PASS (tick)
  • 2.14 Connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.15 Connectivity for [u'olt10', u'vsg10'] CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.16 Connectivity for [u'olt5', u'vsg5'] CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.17 Recovering ONOS instance - PASS (tick)
  • 2.18 Checking if ONOS CLI is ready - PASS (tick)
  • 2.19 Checking if ONOS CLI is ready - PASS (tick)
  • 2.20 Checking if ONOS CLI is ready - PASS (tick)
  • 2.21 Checking ONOS nodes - PASS (tick)
  • 2.22 Check whether the flow count is bigger than 350 - FAIL (error)
    • Flow count looks wrong: False
  • 2.23 Check whether all flow status are ADDED - PASS (tick)
  • 2.24 Connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.25 Connectivity for [u'olt10', u'vsg10'] CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.26 Connectivity for [u'olt5', u'vsg5'] CASE3_Recovery - FAIL (error)
    • IP connectivity failed
  • 2.27 Stopping Mininet - PASS (tick)
  • 2.28 Copying karaf logs - PASS (tick)

Case 3: Copy karaf logs - FAIL

Copying the karaf logs to preserve them throughreinstalling ONOS

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Creating ONOS package - PASS (tick)
  • 3.3 Installing ONOS package - PASS (tick)
  • 3.4 Set up ONOS secure SSH - PASS (tick)
  • 3.5 Checking ONOS service - PASS (tick)
  • 3.6 Checking if ONOS CLI is ready - PASS (tick)
  • 3.7 Starting Mininet Topology - PASS (tick)
  • 3.8 Check whether the flow count is bigger than 15 - FAIL (error)
    • Flow count looks wrong: False
  • 3.9 Check whether all flow status are ADDED - PASS (tick)
  • 3.10 Connectivity for [u'h1', u'h2'] CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.11 Connectivity for [u'olt10', u'vsg10'] CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.12 Connectivity for [u'olt5', u'vsg5'] CASE3 - FAIL (error)
    • IP connectivity failed
  • 3.13 Killing ONOS instance - PASS (tick)
  • 3.14 Connectivity for [u'h1', u'h2'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.15 Connectivity for [u'olt10', u'vsg10'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.16 Connectivity for [u'olt5', u'vsg5'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.17 Recovering ONOS instance - PASS (tick)
  • 3.18 Checking if ONOS CLI is ready - PASS (tick)
  • 3.19 Checking if ONOS CLI is ready - PASS (tick)
  • 3.20 Checking if ONOS CLI is ready - PASS (tick)
  • 3.21 Checking ONOS nodes - PASS (tick)
  • 3.22 Check whether the flow count is bigger than 15 - FAIL (error)
    • Flow count looks wrong: False
  • 3.23 Check whether all flow status are ADDED - PASS (tick)
  • 3.24 Connectivity for [u'h1', u'h2'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.25 Connectivity for [u'olt10', u'vsg10'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.26 Connectivity for [u'olt5', u'vsg5'] CASE3_Failure - FAIL (error)
    • IP connectivity failed
  • 3.27 Stopping Mininet - PASS (tick)
  • 3.28 Copying karaf logs - PASS (tick)
  • No labels