Case 101: Test link failures with IPv4 hosts, ONOS cluster size: 3 - PASS

  • 101.1 Constructing test variables - No Result (warning)
  • 101.2 Constructing test variables - PASS (tick)
  • 101.3 Apply cell to environment - PASS (tick)
  • 101.4 Uninstalling ONOS package - PASS (tick)
  • 101.5 Creating ONOS package - PASS (tick)
  • 101.6 Installing ONOS package - PASS (tick)
  • 101.7 Set up ONOS secure SSH - PASS (tick)
  • 101.8 Checking ONOS service - PASS (tick)
  • 101.9 Starting ONOS CLI sessions - PASS (tick)
  • 101.10 Starting Mininet Topology - PASS (tick)
  • 101.11 Verify host IP address assignment in ONOS - PASS (tick)
  • 101.12 Verify IP address assignment from hosts - PASS (tick)
  • 101.13 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE101 - PASS (tick)
  • 101.14 Killing a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 101.15 Verify host IP address assignment in ONOS - PASS (tick)
  • 101.16 Verify IP address assignment from hosts - PASS (tick)
  • 101.17 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE101 - PASS (tick)
  • 101.18 Restoring a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 101.19 Verify host IP address assignment in ONOS - PASS (tick)
  • 101.20 Verify IP address assignment from hosts - PASS (tick)
  • 101.21 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE101 - PASS (tick)
  • 101.22 Killing a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 101.23 Verify host IP address assignment in ONOS - PASS (tick)
  • 101.24 Verify IP address assignment from hosts - PASS (tick)
  • 101.25 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE101 - PASS (tick)
  • 101.26 Restoring a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 101.27 Verify host IP address assignment in ONOS - PASS (tick)
  • 101.28 Verify IP address assignment from hosts - PASS (tick)
  • 101.29 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE101 - PASS (tick)
  • 101.30 Stopping Mininet - PASS (tick)
  • 101.31 Copying karaf logs - PASS (tick)

Case 102: Test link failures with IPv6 hosts, ONOS cluster size: 3 - FAIL

  • 102.1 Apply cell to environment - PASS (tick)
  • 102.2 Uninstalling ONOS package - PASS (tick)
  • 102.3 Installing ONOS package - PASS (tick)
  • 102.4 Set up ONOS secure SSH - PASS (tick)
  • 102.5 Checking ONOS service - PASS (tick)
  • 102.6 Starting ONOS CLI sessions - PASS (tick)
  • 102.7 Starting Mininet Topology - PASS (tick)
  • 102.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 102.9 Verify IP address assignment from hosts - PASS (tick)
  • 102.10 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE102 - PASS (tick)
  • 102.11 Killing a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 102.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 102.13 Verify IP address assignment from hosts - PASS (tick)
  • 102.14 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE102 - FAIL (error)
    • IPv6 connectivity failed
  • 102.15 Restoring a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 102.16 Verify host IP address assignment in ONOS - PASS (tick)
  • 102.17 Verify IP address assignment from hosts - PASS (tick)
  • 102.18 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE102 - FAIL (error)
    • IPv6 connectivity failed
  • 102.19 Killing a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 102.20 Verify host IP address assignment in ONOS - PASS (tick)
  • 102.21 Verify IP address assignment from hosts - PASS (tick)
  • 102.22 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE102 - FAIL (error)
    • IPv6 connectivity failed
  • 102.23 Restoring a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 102.24 Verify host IP address assignment in ONOS - PASS (tick)
  • 102.25 Verify IP address assignment from hosts - PASS (tick)
  • 102.26 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE102 - FAIL (error)
    • IPv6 connectivity failed
  • 102.27 Stopping Mininet - PASS (tick)
  • 102.28 Copying karaf logs - PASS (tick)

Case 103: Test link failures with IPv4 and IPv6 hosts, ONOS cluster size: 3 - FAIL

  • 103.1 Apply cell to environment - PASS (tick)
  • 103.2 Uninstalling ONOS package - PASS (tick)
  • 103.3 Installing ONOS package - PASS (tick)
  • 103.4 Set up ONOS secure SSH - PASS (tick)
  • 103.5 Checking ONOS service - PASS (tick)
  • 103.6 Starting ONOS CLI sessions - PASS (tick)
  • 103.7 Starting Mininet Topology - PASS (tick)
  • 103.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 103.9 Verify IP address assignment from hosts - PASS (tick)
  • 103.10 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE103 - FAIL (error)
    • IPv4 connectivity failed
  • 103.11 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE103 - FAIL (error)
    • IPv6 connectivity failed
  • 103.12 Killing a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 103.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 103.14 Verify IP address assignment from hosts - PASS (tick)
  • 103.15 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE103 - FAIL (error)
    • IPv4 connectivity failed
  • 103.16 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE103 - FAIL (error)
    • IPv6 connectivity failed
  • 103.17 Restoring a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 103.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 103.19 Verify IP address assignment from hosts - PASS (tick)
  • 103.20 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE103 - FAIL (error)
    • IPv4 connectivity failed
  • 103.21 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE103 - FAIL (error)
    • IPv6 connectivity failed
  • 103.22 Killing a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 103.23 Verify host IP address assignment in ONOS - PASS (tick)
  • 103.24 Verify IP address assignment from hosts - PASS (tick)
  • 103.25 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE103 - FAIL (error)
    • IPv4 connectivity failed
  • 103.26 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE103 - FAIL (error)
    • IPv6 connectivity failed
  • 103.27 Restoring a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 103.28 Verify host IP address assignment in ONOS - PASS (tick)
  • 103.29 Verify IP address assignment from hosts - PASS (tick)
  • 103.30 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE103 - FAIL (error)
    • IPv4 connectivity failed
  • 103.31 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE103 - FAIL (error)
    • IPv6 connectivity failed
  • 103.32 Stopping Mininet - PASS (tick)
  • 103.33 Copying karaf logs - PASS (tick)

Case 104: Test link failures with IPv4 hosts (including external hosts), ONOS cluster size: 3 - FAIL

  • 104.1 Apply cell to environment - PASS (tick)
  • 104.2 Uninstalling ONOS package - PASS (tick)
  • 104.3 Installing ONOS package - PASS (tick)
  • 104.4 Set up ONOS secure SSH - PASS (tick)
  • 104.5 Checking ONOS service - PASS (tick)
  • 104.6 Starting ONOS CLI sessions - PASS (tick)
  • 104.7 Starting Mininet Topology - PASS (tick)
  • 104.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 104.9 Verify IP address assignment from hosts - PASS (tick)
  • 104.10 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE104 - FAIL (error)
    • IPv4 connectivity failed
  • 104.11 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE104 - PASS (tick)
  • 104.12 Killing a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 104.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 104.14 Verify IP address assignment from hosts - PASS (tick)
  • 104.15 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE104 - FAIL (error)
    • IPv4 connectivity failed
  • 104.16 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE104 - PASS (tick)
  • 104.17 Restoring a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 104.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 104.19 Verify IP address assignment from hosts - PASS (tick)
  • 104.20 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE104 - PASS (tick)
  • 104.21 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE104 - PASS (tick)
  • 104.22 Killing a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 104.23 Verify host IP address assignment in ONOS - PASS (tick)
  • 104.24 Verify IP address assignment from hosts - PASS (tick)
  • 104.25 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE104 - FAIL (error)
    • IPv4 connectivity failed
  • 104.26 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE104 - PASS (tick)
  • 104.27 Restoring a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 104.28 Verify host IP address assignment in ONOS - PASS (tick)
  • 104.29 Verify IP address assignment from hosts - PASS (tick)
  • 104.30 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE104 - PASS (tick)
  • 104.31 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE104 - PASS (tick)
  • 104.32 Stopping Mininet - PASS (tick)
  • 104.33 Copying karaf logs - PASS (tick)

Case 105: Test link failures with IPv6 hosts (including external hosts), ONOS cluster size: 3 - FAIL

  • 105.1 Apply cell to environment - PASS (tick)
  • 105.2 Uninstalling ONOS package - PASS (tick)
  • 105.3 Installing ONOS package - PASS (tick)
  • 105.4 Set up ONOS secure SSH - PASS (tick)
  • 105.5 Checking ONOS service - PASS (tick)
  • 105.6 Starting ONOS CLI sessions - PASS (tick)
  • 105.7 Starting Mininet Topology - PASS (tick)
  • 105.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 105.9 Verify IP address assignment from hosts - PASS (tick)
  • 105.10 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.11 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.12 Killing a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 105.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 105.14 Verify IP address assignment from hosts - PASS (tick)
  • 105.15 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.16 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.17 Restoring a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 105.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 105.19 Verify IP address assignment from hosts - PASS (tick)
  • 105.20 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.21 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.22 Killing a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 105.23 Verify host IP address assignment in ONOS - PASS (tick)
  • 105.24 Verify IP address assignment from hosts - PASS (tick)
  • 105.25 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.26 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.27 Restoring a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 105.28 Verify host IP address assignment in ONOS - PASS (tick)
  • 105.29 Verify IP address assignment from hosts - PASS (tick)
  • 105.30 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.31 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE105 - FAIL (error)
    • IPv6 connectivity failed
  • 105.32 Stopping Mininet - PASS (tick)
  • 105.33 Copying karaf logs - PASS (tick)

Case 106: Test link failures with IPv4 and IPv6 hosts (including external hosts), ONOS cluster size: 3 - FAIL

  • 106.1 Apply cell to environment - PASS (tick)
  • 106.2 Uninstalling ONOS package - PASS (tick)
  • 106.3 Installing ONOS package - PASS (tick)
  • 106.4 Set up ONOS secure SSH - PASS (tick)
  • 106.5 Checking ONOS service - PASS (tick)
  • 106.6 Starting ONOS CLI sessions - PASS (tick)
  • 106.7 Starting Mininet Topology - PASS (tick)
  • 106.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 106.9 Verify IP address assignment from hosts - PASS (tick)
  • 106.10 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.11 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.12 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.13 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.14 Killing a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 106.15 Verify host IP address assignment in ONOS - PASS (tick)
  • 106.16 Verify IP address assignment from hosts - PASS (tick)
  • 106.17 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.18 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.19 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.20 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.21 Restoring a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 106.22 Verify host IP address assignment in ONOS - PASS (tick)
  • 106.23 Verify IP address assignment from hosts - PASS (tick)
  • 106.24 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.25 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.26 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.27 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.28 Killing a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 106.29 Verify host IP address assignment in ONOS - PASS (tick)
  • 106.30 Verify IP address assignment from hosts - PASS (tick)
  • 106.31 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.32 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.33 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.34 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.35 Restoring a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 106.36 Verify host IP address assignment in ONOS - PASS (tick)
  • 106.37 Verify IP address assignment from hosts - PASS (tick)
  • 106.38 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.39 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.40 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE106 - FAIL (error)
    • IPv4 connectivity failed
  • 106.41 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE106 - FAIL (error)
    • IPv6 connectivity failed
  • 106.42 Stopping Mininet - PASS (tick)
  • 106.43 Copying karaf logs - PASS (tick)

Case 107: Test link failures with IPv4 hosts (including external host configured with route-add command), ONOS cluster size: 3 - FAIL

  • 107.1 Apply cell to environment - PASS (tick)
  • 107.2 Uninstalling ONOS package - PASS (tick)
  • 107.3 Installing ONOS package - PASS (tick)
  • 107.4 Set up ONOS secure SSH - PASS (tick)
  • 107.5 Checking ONOS service - PASS (tick)
  • 107.6 Starting ONOS CLI sessions - PASS (tick)
  • 107.7 Add static route for subnet 10.0.88.0/24 towards router interface 10.0.1.1 - PASS (tick)
  • 107.8 Starting Mininet Topology - PASS (tick)
  • 107.9 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.10 Verify IP address assignment from hosts - PASS (tick)
  • 107.11 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE107 - FAIL (error)
    • IPv4 connectivity failed
  • 107.12 Killing a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 107.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.14 Verify IP address assignment from hosts - PASS (tick)
  • 107.15 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE107 - FAIL (error)
    • IPv4 connectivity failed
  • 107.16 Restoring a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 107.17 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.18 Verify IP address assignment from hosts - PASS (tick)
  • 107.19 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE107 - FAIL (error)
    • IPv4 connectivity failed
  • 107.20 Killing a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 107.21 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.22 Verify IP address assignment from hosts - PASS (tick)
  • 107.23 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE107 - FAIL (error)
    • IPv4 connectivity failed
  • 107.24 Restoring a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 107.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 107.26 Verify IP address assignment from hosts - PASS (tick)
  • 107.27 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE107 - FAIL (error)
    • IPv4 connectivity failed
  • 107.28 Stopping Mininet - PASS (tick)
  • 107.29 Copying karaf logs - PASS (tick)

Case 108: Test link failures with IPv6 hosts (including external host configured with route-add command), ONOS cluster size: 3 - FAIL

  • 108.1 Apply cell to environment - PASS (tick)
  • 108.2 Uninstalling ONOS package - PASS (tick)
  • 108.3 Installing ONOS package - PASS (tick)
  • 108.4 Set up ONOS secure SSH - PASS (tick)
  • 108.5 Checking ONOS service - PASS (tick)
  • 108.6 Starting ONOS CLI sessions - PASS (tick)
  • 108.7 Add static route for subnet 2000::8700/120 towards router interface 2000::101 - PASS (tick)
  • 108.8 Starting Mininet Topology - PASS (tick)
  • 108.9 Verify host IP address assignment in ONOS - PASS (tick)
  • 108.10 Verify IP address assignment from hosts - PASS (tick)
  • 108.11 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE108 - FAIL (error)
    • IPv6 connectivity failed
  • 108.12 Killing a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 108.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 108.14 Verify IP address assignment from hosts - PASS (tick)
  • 108.15 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE108 - FAIL (error)
    • IPv6 connectivity failed
  • 108.16 Restoring a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 108.17 Verify host IP address assignment in ONOS - PASS (tick)
  • 108.18 Verify IP address assignment from hosts - PASS (tick)
  • 108.19 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE108 - FAIL (error)
    • IPv6 connectivity failed
  • 108.20 Killing a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 108.21 Verify host IP address assignment in ONOS - PASS (tick)
  • 108.22 Verify IP address assignment from hosts - PASS (tick)
  • 108.23 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE108 - FAIL (error)
    • IPv6 connectivity failed
  • 108.24 Restoring a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 108.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 108.26 Verify IP address assignment from hosts - PASS (tick)
  • 108.27 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE108 - FAIL (error)
    • IPv6 connectivity failed
  • 108.28 Stopping Mininet - PASS (tick)
  • 108.29 Copying karaf logs - PASS (tick)

Case 109: Test link failures with IPv4 and IPv6 hosts (including external host configured with route-add command), ONOS cluster size: 3 - PASS

  • 109.1 Apply cell to environment - PASS (tick)
  • 109.2 Uninstalling ONOS package - PASS (tick)
  • 109.3 Installing ONOS package - PASS (tick)
  • 109.4 Set up ONOS secure SSH - PASS (tick)
  • 109.5 Checking ONOS service - PASS (tick)
  • 109.6 Starting ONOS CLI sessions - PASS (tick)
  • 109.7 Add static route for subnet 10.0.88.0/24 towards router interface 10.0.1.1 - PASS (tick)
  • 109.8 Add static route for subnet 2000::8700/120 towards router interface 2000::101 - PASS (tick)
  • 109.9 Starting Mininet Topology - PASS (tick)
  • 109.10 Verify host IP address assignment in ONOS - PASS (tick)
  • 109.11 Verify IP address assignment from hosts - PASS (tick)
  • 109.12 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE109 - PASS (tick)
  • 109.13 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE109 - PASS (tick)
  • 109.14 Killing a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 109.15 Verify host IP address assignment in ONOS - PASS (tick)
  • 109.16 Verify IP address assignment from hosts - PASS (tick)
  • 109.17 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE109 - PASS (tick)
  • 109.18 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE109 - PASS (tick)
  • 109.19 Restoring a batch of links [[u'leaf5', u'spine101'], [u'leaf4', u'spine101'], [u'leaf1', u'spine101'], [u'leaf3', u'spine101'], [u'leaf2', u'spine101']] - PASS (tick)
  • 109.20 Verify host IP address assignment in ONOS - PASS (tick)
  • 109.21 Verify IP address assignment from hosts - PASS (tick)
  • 109.22 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE109 - PASS (tick)
  • 109.23 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE109 - PASS (tick)
  • 109.24 Killing a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 109.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 109.26 Verify IP address assignment from hosts - PASS (tick)
  • 109.27 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE109 - PASS (tick)
  • 109.28 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE109 - PASS (tick)
  • 109.29 Restoring a batch of links [[u'leaf5', u'spine102'], [u'leaf4', u'spine102'], [u'leaf1', u'spine102'], [u'leaf3', u'spine102'], [u'leaf2', u'spine102']] - PASS (tick)
  • 109.30 Verify host IP address assignment in ONOS - PASS (tick)
  • 109.31 Verify IP address assignment from hosts - PASS (tick)
  • 109.32 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE109 - PASS (tick)
  • 109.33 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE109 - PASS (tick)
  • 109.34 Stopping Mininet - PASS (tick)
  • 109.35 Copying karaf logs - PASS (tick)

Case 201: Test switch failures with IPv4 hosts, ONOS cluster size: 3 - FAIL

  • 201.1 Apply cell to environment - PASS (tick)
  • 201.2 Uninstalling ONOS package - PASS (tick)
  • 201.3 Installing ONOS package - PASS (tick)
  • 201.4 Set up ONOS secure SSH - PASS (tick)
  • 201.5 Checking ONOS service - PASS (tick)
  • 201.6 Starting ONOS CLI sessions - PASS (tick)
  • 201.7 Starting Mininet Topology - PASS (tick)
  • 201.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.9 Verify IP address assignment from hosts - PASS (tick)
  • 201.10 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE201 - FAIL (error)
    • IPv4 connectivity failed
  • 201.11 Kill spine102 - PASS (tick)
  • 201.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.13 Verify IP address assignment from hosts - PASS (tick)
  • 201.14 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE201 - FAIL (error)
    • IPv4 connectivity failed
  • 201.15 Recovering spine102 - PASS (tick)
  • 201.16 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.17 Verify IP address assignment from hosts - PASS (tick)
  • 201.18 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE201 - FAIL (error)
    • IPv4 connectivity failed
  • 201.19 Kill spine101 - PASS (tick)
  • 201.20 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.21 Verify IP address assignment from hosts - PASS (tick)
  • 201.22 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE201 - PASS (tick)
  • 201.23 Recovering spine101 - PASS (tick)
  • 201.24 Verify host IP address assignment in ONOS - PASS (tick)
  • 201.25 Verify IP address assignment from hosts - PASS (tick)
  • 201.26 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE201 - PASS (tick)
  • 201.27 Stopping Mininet - PASS (tick)
  • 201.28 Copying karaf logs - PASS (tick)

Case 202: Test switch failures with IPv6 hosts, ONOS cluster size: 3 - PASS

  • 202.1 Apply cell to environment - PASS (tick)
  • 202.2 Uninstalling ONOS package - PASS (tick)
  • 202.3 Installing ONOS package - PASS (tick)
  • 202.4 Set up ONOS secure SSH - PASS (tick)
  • 202.5 Checking ONOS service - PASS (tick)
  • 202.6 Starting ONOS CLI sessions - PASS (tick)
  • 202.7 Starting Mininet Topology - PASS (tick)
  • 202.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 202.9 Verify IP address assignment from hosts - PASS (tick)
  • 202.10 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE202 - PASS (tick)
  • 202.11 Kill spine102 - PASS (tick)
  • 202.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 202.13 Verify IP address assignment from hosts - PASS (tick)
  • 202.14 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE202 - PASS (tick)
  • 202.15 Recovering spine102 - PASS (tick)
  • 202.16 Verify host IP address assignment in ONOS - PASS (tick)
  • 202.17 Verify IP address assignment from hosts - PASS (tick)
  • 202.18 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE202 - PASS (tick)
  • 202.19 Kill spine101 - PASS (tick)
  • 202.20 Verify host IP address assignment in ONOS - PASS (tick)
  • 202.21 Verify IP address assignment from hosts - PASS (tick)
  • 202.22 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE202 - PASS (tick)
  • 202.23 Recovering spine101 - PASS (tick)
  • 202.24 Verify host IP address assignment in ONOS - PASS (tick)
  • 202.25 Verify IP address assignment from hosts - PASS (tick)
  • 202.26 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE202 - PASS (tick)
  • 202.27 Stopping Mininet - PASS (tick)
  • 202.28 Copying karaf logs - PASS (tick)

Case 203: Test switch failures with IPv4 and IPv6 hosts, ONOS cluster size: 3 - PASS

  • 203.1 Apply cell to environment - PASS (tick)
  • 203.2 Uninstalling ONOS package - PASS (tick)
  • 203.3 Installing ONOS package - PASS (tick)
  • 203.4 Set up ONOS secure SSH - PASS (tick)
  • 203.5 Checking ONOS service - PASS (tick)
  • 203.6 Starting ONOS CLI sessions - PASS (tick)
  • 203.7 Starting Mininet Topology - PASS (tick)
  • 203.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 203.9 Verify IP address assignment from hosts - PASS (tick)
  • 203.10 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE203 - PASS (tick)
  • 203.11 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE203 - PASS (tick)
  • 203.12 Kill spine102 - PASS (tick)
  • 203.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 203.14 Verify IP address assignment from hosts - PASS (tick)
  • 203.15 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE203 - PASS (tick)
  • 203.16 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE203 - PASS (tick)
  • 203.17 Recovering spine102 - PASS (tick)
  • 203.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 203.19 Verify IP address assignment from hosts - PASS (tick)
  • 203.20 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE203 - PASS (tick)
  • 203.21 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE203 - PASS (tick)
  • 203.22 Kill spine101 - PASS (tick)
  • 203.23 Verify host IP address assignment in ONOS - PASS (tick)
  • 203.24 Verify IP address assignment from hosts - PASS (tick)
  • 203.25 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE203 - PASS (tick)
  • 203.26 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE203 - PASS (tick)
  • 203.27 Recovering spine101 - PASS (tick)
  • 203.28 Verify host IP address assignment in ONOS - PASS (tick)
  • 203.29 Verify IP address assignment from hosts - PASS (tick)
  • 203.30 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE203 - PASS (tick)
  • 203.31 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE203 - PASS (tick)
  • 203.32 Stopping Mininet - PASS (tick)
  • 203.33 Copying karaf logs - PASS (tick)

Case 204: Test switch failures with IPv4 hosts (including external hosts), ONOS cluster size: 3 - PASS

  • 204.1 Apply cell to environment - PASS (tick)
  • 204.2 Uninstalling ONOS package - PASS (tick)
  • 204.3 Installing ONOS package - PASS (tick)
  • 204.4 Set up ONOS secure SSH - PASS (tick)
  • 204.5 Checking ONOS service - PASS (tick)
  • 204.6 Starting ONOS CLI sessions - PASS (tick)
  • 204.7 Starting Mininet Topology - PASS (tick)
  • 204.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.9 Verify IP address assignment from hosts - PASS (tick)
  • 204.10 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE204 - PASS (tick)
  • 204.11 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE204 - PASS (tick)
  • 204.12 Kill spine102 - PASS (tick)
  • 204.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.14 Verify IP address assignment from hosts - PASS (tick)
  • 204.15 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE204 - PASS (tick)
  • 204.16 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE204 - PASS (tick)
  • 204.17 Recovering spine102 - PASS (tick)
  • 204.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.19 Verify IP address assignment from hosts - PASS (tick)
  • 204.20 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE204 - PASS (tick)
  • 204.21 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE204 - PASS (tick)
  • 204.22 Kill spine101 - PASS (tick)
  • 204.23 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.24 Verify IP address assignment from hosts - PASS (tick)
  • 204.25 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE204 - PASS (tick)
  • 204.26 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE204 - PASS (tick)
  • 204.27 Recovering spine101 - PASS (tick)
  • 204.28 Verify host IP address assignment in ONOS - PASS (tick)
  • 204.29 Verify IP address assignment from hosts - PASS (tick)
  • 204.30 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE204 - PASS (tick)
  • 204.31 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE204 - PASS (tick)
  • 204.32 Stopping Mininet - PASS (tick)
  • 204.33 Copying karaf logs - PASS (tick)

Case 205: Test switch failures with IPv6 hosts (including external hosts), ONOS cluster size: 3 - FAIL

  • 205.1 Apply cell to environment - PASS (tick)
  • 205.2 Uninstalling ONOS package - PASS (tick)
  • 205.3 Installing ONOS package - PASS (tick)
  • 205.4 Set up ONOS secure SSH - PASS (tick)
  • 205.5 Checking ONOS service - PASS (tick)
  • 205.6 Starting ONOS CLI sessions - PASS (tick)
  • 205.7 Starting Mininet Topology - PASS (tick)
  • 205.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 205.9 Verify IP address assignment from hosts - PASS (tick)
  • 205.10 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE205 - FAIL (error)
    • IPv6 connectivity failed
  • 205.11 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE205 - PASS (tick)
  • 205.12 Kill spine102 - PASS (tick)
  • 205.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 205.14 Verify IP address assignment from hosts - PASS (tick)
  • 205.15 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE205 - FAIL (error)
    • IPv6 connectivity failed
  • 205.16 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE205 - PASS (tick)
  • 205.17 Recovering spine102 - PASS (tick)
  • 205.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 205.19 Verify IP address assignment from hosts - PASS (tick)
  • 205.20 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE205 - FAIL (error)
    • IPv6 connectivity failed
  • 205.21 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE205 - PASS (tick)
  • 205.22 Kill spine101 - PASS (tick)
  • 205.23 Verify host IP address assignment in ONOS - PASS (tick)
  • 205.24 Verify IP address assignment from hosts - PASS (tick)
  • 205.25 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE205 - FAIL (error)
    • IPv6 connectivity failed
  • 205.26 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE205 - PASS (tick)
  • 205.27 Recovering spine101 - PASS (tick)
  • 205.28 Verify host IP address assignment in ONOS - PASS (tick)
  • 205.29 Verify IP address assignment from hosts - PASS (tick)
  • 205.30 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE205 - PASS (tick)
  • 205.31 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE205 - PASS (tick)
  • 205.32 Stopping Mininet - PASS (tick)
  • 205.33 Copying karaf logs - PASS (tick)

Case 206: Test switch failures with IPv4 and IPv6 hosts (including external hosts), ONOS cluster size: 3 - FAIL

  • 206.1 Apply cell to environment - PASS (tick)
  • 206.2 Uninstalling ONOS package - PASS (tick)
  • 206.3 Installing ONOS package - PASS (tick)
  • 206.4 Set up ONOS secure SSH - PASS (tick)
  • 206.5 Checking ONOS service - PASS (tick)
  • 206.6 Starting ONOS CLI sessions - PASS (tick)
  • 206.7 Starting Mininet Topology - PASS (tick)
  • 206.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 206.9 Verify IP address assignment from hosts - PASS (tick)
  • 206.10 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE206 - FAIL (error)
    • IPv6 connectivity failed
  • 206.11 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE206 - PASS (tick)
  • 206.12 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE206 - PASS (tick)
  • 206.13 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE206 - PASS (tick)
  • 206.14 Kill spine102 - PASS (tick)
  • 206.15 Verify host IP address assignment in ONOS - PASS (tick)
  • 206.16 Verify IP address assignment from hosts - PASS (tick)
  • 206.17 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE206 - FAIL (error)
    • IPv6 connectivity failed
  • 206.18 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE206 - PASS (tick)
  • 206.19 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE206 - PASS (tick)
  • 206.20 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE206 - PASS (tick)
  • 206.21 Recovering spine102 - PASS (tick)
  • 206.22 Verify host IP address assignment in ONOS - PASS (tick)
  • 206.23 Verify IP address assignment from hosts - PASS (tick)
  • 206.24 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE206 - FAIL (error)
    • IPv6 connectivity failed
  • 206.25 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE206 - FAIL (error)
    • IPv4 connectivity failed
  • 206.26 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE206 - PASS (tick)
  • 206.27 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE206 - PASS (tick)
  • 206.28 Kill spine101 - PASS (tick)
  • 206.29 Verify host IP address assignment in ONOS - PASS (tick)
  • 206.30 Verify IP address assignment from hosts - PASS (tick)
  • 206.31 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE206 - FAIL (error)
    • IPv6 connectivity failed
  • 206.32 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE206 - FAIL (error)
    • IPv4 connectivity failed
  • 206.33 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE206 - PASS (tick)
  • 206.34 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE206 - PASS (tick)
  • 206.35 Recovering spine101 - PASS (tick)
  • 206.36 Verify host IP address assignment in ONOS - PASS (tick)
  • 206.37 Verify IP address assignment from hosts - PASS (tick)
  • 206.38 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE206 - PASS (tick)
  • 206.39 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE206 - PASS (tick)
  • 206.40 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE206 - PASS (tick)
  • 206.41 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE206 - PASS (tick)
  • 206.42 Stopping Mininet - PASS (tick)
  • 206.43 Copying karaf logs - PASS (tick)

Case 207: Test switch failures with IPv4 hosts (including external host configured with route-add command), ONOS cluster size: 3 - PASS

  • 207.1 Apply cell to environment - PASS (tick)
  • 207.2 Uninstalling ONOS package - PASS (tick)
  • 207.3 Installing ONOS package - PASS (tick)
  • 207.4 Set up ONOS secure SSH - PASS (tick)
  • 207.5 Checking ONOS service - PASS (tick)
  • 207.6 Starting ONOS CLI sessions - PASS (tick)
  • 207.7 Add static route for subnet 10.0.88.0/24 towards router interface 10.0.1.1 - PASS (tick)
  • 207.8 Starting Mininet Topology - PASS (tick)
  • 207.9 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.10 Verify IP address assignment from hosts - PASS (tick)
  • 207.11 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE207 - PASS (tick)
  • 207.12 Kill spine102 - PASS (tick)
  • 207.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.14 Verify IP address assignment from hosts - PASS (tick)
  • 207.15 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE207 - PASS (tick)
  • 207.16 Recovering spine102 - PASS (tick)
  • 207.17 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.18 Verify IP address assignment from hosts - PASS (tick)
  • 207.19 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE207 - PASS (tick)
  • 207.20 Kill spine101 - PASS (tick)
  • 207.21 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.22 Verify IP address assignment from hosts - PASS (tick)
  • 207.23 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE207 - PASS (tick)
  • 207.24 Recovering spine101 - PASS (tick)
  • 207.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 207.26 Verify IP address assignment from hosts - PASS (tick)
  • 207.27 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE207 - PASS (tick)
  • 207.28 Stopping Mininet - PASS (tick)
  • 207.29 Copying karaf logs - PASS (tick)

Case 208: Test switch failures with IPv6 hosts (including external host configured with route-add command), ONOS cluster size: 3 - PASS

  • 208.1 Apply cell to environment - PASS (tick)
  • 208.2 Uninstalling ONOS package - PASS (tick)
  • 208.3 Installing ONOS package - PASS (tick)
  • 208.4 Set up ONOS secure SSH - PASS (tick)
  • 208.5 Checking ONOS service - PASS (tick)
  • 208.6 Starting ONOS CLI sessions - PASS (tick)
  • 208.7 Add static route for subnet 2000::8700/120 towards router interface 2000::101 - PASS (tick)
  • 208.8 Starting Mininet Topology - PASS (tick)
  • 208.9 Verify host IP address assignment in ONOS - PASS (tick)
  • 208.10 Verify IP address assignment from hosts - PASS (tick)
  • 208.11 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE208 - PASS (tick)
  • 208.12 Kill spine102 - PASS (tick)
  • 208.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 208.14 Verify IP address assignment from hosts - PASS (tick)
  • 208.15 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE208 - PASS (tick)
  • 208.16 Recovering spine102 - PASS (tick)
  • 208.17 Verify host IP address assignment in ONOS - PASS (tick)
  • 208.18 Verify IP address assignment from hosts - PASS (tick)
  • 208.19 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE208 - PASS (tick)
  • 208.20 Kill spine101 - PASS (tick)
  • 208.21 Verify host IP address assignment in ONOS - PASS (tick)
  • 208.22 Verify IP address assignment from hosts - PASS (tick)
  • 208.23 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE208 - PASS (tick)
  • 208.24 Recovering spine101 - PASS (tick)
  • 208.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 208.26 Verify IP address assignment from hosts - PASS (tick)
  • 208.27 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE208 - PASS (tick)
  • 208.28 Stopping Mininet - PASS (tick)
  • 208.29 Copying karaf logs - PASS (tick)

Case 209: Test switch failures with IPv4 and IPv6 hosts (including external host configured with route-add command), ONOS cluster size: 3 - FAIL

  • 209.1 Apply cell to environment - PASS (tick)
  • 209.2 Uninstalling ONOS package - PASS (tick)
  • 209.3 Installing ONOS package - PASS (tick)
  • 209.4 Set up ONOS secure SSH - PASS (tick)
  • 209.5 Checking ONOS service - PASS (tick)
  • 209.6 Starting ONOS CLI sessions - PASS (tick)
  • 209.7 Add static route for subnet 10.0.88.0/24 towards router interface 10.0.1.1 - PASS (tick)
  • 209.8 Add static route for subnet 2000::8700/120 towards router interface 2000::101 - PASS (tick)
  • 209.9 Starting Mininet Topology - PASS (tick)
  • 209.10 Verify host IP address assignment in ONOS - PASS (tick)
  • 209.11 Verify IP address assignment from hosts - PASS (tick)
  • 209.12 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE209 - FAIL (error)
    • IPv4 connectivity failed
  • 209.13 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE209 - FAIL (error)
    • IPv6 connectivity failed
  • 209.14 Kill spine102 - PASS (tick)
  • 209.15 Verify host IP address assignment in ONOS - PASS (tick)
  • 209.16 Verify IP address assignment from hosts - PASS (tick)
  • 209.17 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE209 - FAIL (error)
    • IPv4 connectivity failed
  • 209.18 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE209 - FAIL (error)
    • IPv6 connectivity failed
  • 209.19 Recovering spine102 - PASS (tick)
  • 209.20 Verify host IP address assignment in ONOS - PASS (tick)
  • 209.21 Verify IP address assignment from hosts - PASS (tick)
  • 209.22 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE209 - FAIL (error)
    • IPv4 connectivity failed
  • 209.23 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE209 - FAIL (error)
    • IPv6 connectivity failed
  • 209.24 Kill spine101 - PASS (tick)
  • 209.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 209.26 Verify IP address assignment from hosts - PASS (tick)
  • 209.27 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE209 - PASS (tick)
  • 209.28 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE209 - PASS (tick)
  • 209.29 Recovering spine101 - PASS (tick)
  • 209.30 Verify host IP address assignment in ONOS - PASS (tick)
  • 209.31 Verify IP address assignment from hosts - PASS (tick)
  • 209.32 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE209 - PASS (tick)
  • 209.33 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE209 - PASS (tick)
  • 209.34 Stopping Mininet - PASS (tick)
  • 209.35 Copying karaf logs - PASS (tick)

Case 301: Test node failures with IPv4 hosts, ONOS cluster size: 3 - PASS

  • 301.1 Apply cell to environment - PASS (tick)
  • 301.2 Uninstalling ONOS package - PASS (tick)
  • 301.3 Installing ONOS package - PASS (tick)
  • 301.4 Set up ONOS secure SSH - PASS (tick)
  • 301.5 Checking ONOS service - PASS (tick)
  • 301.6 Starting ONOS CLI sessions - PASS (tick)
  • 301.7 Starting Mininet Topology - PASS (tick)
  • 301.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.9 Verify IP address assignment from hosts - PASS (tick)
  • 301.10 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE301 - PASS (tick)
  • 301.11 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 301.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.13 Verify IP address assignment from hosts - PASS (tick)
  • 301.14 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE301 - PASS (tick)
  • 301.15 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 301.16 Checking if ONOS CLI is ready - PASS (tick)
  • 301.17 Checking ONOS nodes - PASS (tick)
  • 301.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.19 Verify IP address assignment from hosts - PASS (tick)
  • 301.20 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE301 - PASS (tick)
  • 301.21 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 301.22 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.23 Verify IP address assignment from hosts - PASS (tick)
  • 301.24 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE301 - PASS (tick)
  • 301.25 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 301.26 Checking if ONOS CLI is ready - PASS (tick)
  • 301.27 Checking ONOS nodes - PASS (tick)
  • 301.28 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.29 Verify IP address assignment from hosts - PASS (tick)
  • 301.30 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE301 - PASS (tick)
  • 301.31 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 301.32 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.33 Verify IP address assignment from hosts - PASS (tick)
  • 301.34 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE301 - PASS (tick)
  • 301.35 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 301.36 Checking if ONOS CLI is ready - PASS (tick)
  • 301.37 Checking ONOS nodes - PASS (tick)
  • 301.38 Verify host IP address assignment in ONOS - PASS (tick)
  • 301.39 Verify IP address assignment from hosts - PASS (tick)
  • 301.40 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE301 - PASS (tick)
  • 301.41 Stopping Mininet - PASS (tick)
  • 301.42 Copying karaf logs - PASS (tick)

Case 302: Test node failures with IPv6 hosts, ONOS cluster size: 3 - FAIL

  • 302.1 Apply cell to environment - PASS (tick)
  • 302.2 Uninstalling ONOS package - PASS (tick)
  • 302.3 Installing ONOS package - PASS (tick)
  • 302.4 Set up ONOS secure SSH - PASS (tick)
  • 302.5 Checking ONOS service - PASS (tick)
  • 302.6 Starting ONOS CLI sessions - PASS (tick)
  • 302.7 Starting Mininet Topology - PASS (tick)
  • 302.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 302.9 Verify IP address assignment from hosts - PASS (tick)
  • 302.10 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE302 - PASS (tick)
  • 302.11 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 302.12 Verify host IP address assignment in ONOS - PASS (tick)
  • 302.13 Verify IP address assignment from hosts - PASS (tick)
  • 302.14 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE302 - PASS (tick)
  • 302.15 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 302.16 Checking if ONOS CLI is ready - PASS (tick)
  • 302.17 Checking ONOS nodes - PASS (tick)
  • 302.18 Verify host IP address assignment in ONOS - PASS (tick)
  • 302.19 Verify IP address assignment from hosts - PASS (tick)
  • 302.20 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE302 - PASS (tick)
  • 302.21 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 302.22 Verify host IP address assignment in ONOS - PASS (tick)
  • 302.23 Verify IP address assignment from hosts - PASS (tick)
  • 302.24 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE302 - FAIL (error)
    • IPv6 connectivity failed
  • 302.25 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 302.26 Checking if ONOS CLI is ready - PASS (tick)
  • 302.27 Checking ONOS nodes - PASS (tick)
  • 302.28 Verify host IP address assignment in ONOS - PASS (tick)
  • 302.29 Verify IP address assignment from hosts - PASS (tick)
  • 302.30 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE302 - FAIL (error)
    • IPv6 connectivity failed
  • 302.31 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 302.32 Verify host IP address assignment in ONOS - PASS (tick)
  • 302.33 Verify IP address assignment from hosts - PASS (tick)
  • 302.34 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE302 - FAIL (error)
    • IPv6 connectivity failed
  • 302.35 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 302.36 Checking if ONOS CLI is ready - PASS (tick)
  • 302.37 Checking ONOS nodes - PASS (tick)
  • 302.38 Verify host IP address assignment in ONOS - PASS (tick)
  • 302.39 Verify IP address assignment from hosts - PASS (tick)
  • 302.40 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE302 - FAIL (error)
    • IPv6 connectivity failed
  • 302.41 Stopping Mininet - PASS (tick)
  • 302.42 Copying karaf logs - PASS (tick)

Case 303: Test node failures with IPv4 and IPv6 hosts, ONOS cluster size: 3 - FAIL

  • 303.1 Apply cell to environment - PASS (tick)
  • 303.2 Uninstalling ONOS package - PASS (tick)
  • 303.3 Installing ONOS package - PASS (tick)
  • 303.4 Set up ONOS secure SSH - PASS (tick)
  • 303.5 Checking ONOS service - PASS (tick)
  • 303.6 Starting ONOS CLI sessions - PASS (tick)
  • 303.7 Starting Mininet Topology - PASS (tick)
  • 303.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 303.9 Verify IP address assignment from hosts - PASS (tick)
  • 303.10 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE303 - PASS (tick)
  • 303.11 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE303 - PASS (tick)
  • 303.12 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 303.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 303.14 Verify IP address assignment from hosts - PASS (tick)
  • 303.15 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE303 - PASS (tick)
  • 303.16 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE303 - PASS (tick)
  • 303.17 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 303.18 Checking if ONOS CLI is ready - PASS (tick)
  • 303.19 Checking ONOS nodes - PASS (tick)
  • 303.20 Verify host IP address assignment in ONOS - PASS (tick)
  • 303.21 Verify IP address assignment from hosts - PASS (tick)
  • 303.22 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE303 - PASS (tick)
  • 303.23 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE303 - PASS (tick)
  • 303.24 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 303.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 303.26 Verify IP address assignment from hosts - PASS (tick)
  • 303.27 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE303 - PASS (tick)
  • 303.28 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE303 - FAIL (error)
    • IPv6 connectivity failed
  • 303.29 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 303.30 Checking if ONOS CLI is ready - PASS (tick)
  • 303.31 Checking ONOS nodes - PASS (tick)
  • 303.32 Verify host IP address assignment in ONOS - PASS (tick)
  • 303.33 Verify IP address assignment from hosts - PASS (tick)
  • 303.34 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE303 - PASS (tick)
  • 303.35 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE303 - FAIL (error)
    • IPv6 connectivity failed
  • 303.36 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 303.37 Verify host IP address assignment in ONOS - PASS (tick)
  • 303.38 Verify IP address assignment from hosts - PASS (tick)
  • 303.39 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE303 - PASS (tick)
  • 303.40 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE303 - FAIL (error)
    • IPv6 connectivity failed
  • 303.41 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 303.42 Checking if ONOS CLI is ready - PASS (tick)
  • 303.43 Checking ONOS nodes - PASS (tick)
  • 303.44 Verify host IP address assignment in ONOS - PASS (tick)
  • 303.45 Verify IP address assignment from hosts - PASS (tick)
  • 303.46 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE303 - PASS (tick)
  • 303.47 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE303 - FAIL (error)
    • IPv6 connectivity failed
  • 303.48 Stopping Mininet - PASS (tick)
  • 303.49 Copying karaf logs - PASS (tick)

Case 304: Test node failures with IPv4 hosts (including external hosts), ONOS cluster size: 3 - FAIL

  • 304.1 Apply cell to environment - PASS (tick)
  • 304.2 Uninstalling ONOS package - PASS (tick)
  • 304.3 Installing ONOS package - PASS (tick)
  • 304.4 Set up ONOS secure SSH - PASS (tick)
  • 304.5 Checking ONOS service - PASS (tick)
  • 304.6 Starting ONOS CLI sessions - PASS (tick)
  • 304.7 Starting Mininet Topology - PASS (tick)
  • 304.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.9 Verify IP address assignment from hosts - PASS (tick)
  • 304.10 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE304 - PASS (tick)
  • 304.11 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE304 - PASS (tick)
  • 304.12 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 304.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.14 Verify IP address assignment from hosts - PASS (tick)
  • 304.15 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE304 - FAIL (error)
    • IPv4 connectivity failed
  • 304.16 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE304 - PASS (tick)
  • 304.17 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 304.18 Checking if ONOS CLI is ready - PASS (tick)
  • 304.19 Checking ONOS nodes - PASS (tick)
  • 304.20 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.21 Verify IP address assignment from hosts - PASS (tick)
  • 304.22 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE304 - PASS (tick)
  • 304.23 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE304 - PASS (tick)
  • 304.24 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 304.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.26 Verify IP address assignment from hosts - PASS (tick)
  • 304.27 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE304 - PASS (tick)
  • 304.28 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE304 - PASS (tick)
  • 304.29 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 304.30 Checking if ONOS CLI is ready - PASS (tick)
  • 304.31 Checking ONOS nodes - PASS (tick)
  • 304.32 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.33 Verify IP address assignment from hosts - PASS (tick)
  • 304.34 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE304 - PASS (tick)
  • 304.35 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE304 - PASS (tick)
  • 304.36 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 304.37 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.38 Verify IP address assignment from hosts - PASS (tick)
  • 304.39 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE304 - FAIL (error)
    • IPv4 connectivity failed
  • 304.40 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE304 - PASS (tick)
  • 304.41 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 304.42 Checking if ONOS CLI is ready - PASS (tick)
  • 304.43 Checking ONOS nodes - PASS (tick)
  • 304.44 Verify host IP address assignment in ONOS - PASS (tick)
  • 304.45 Verify IP address assignment from hosts - PASS (tick)
  • 304.46 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE304 - FAIL (error)
    • IPv4 connectivity failed
  • 304.47 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE304 - PASS (tick)
  • 304.48 Stopping Mininet - PASS (tick)
  • 304.49 Copying karaf logs - PASS (tick)

Case 305: Test node failures with IPv6 hosts (including external hosts), ONOS cluster size: 3 - FAIL

  • 305.1 Apply cell to environment - PASS (tick)
  • 305.2 Uninstalling ONOS package - PASS (tick)
  • 305.3 Installing ONOS package - PASS (tick)
  • 305.4 Set up ONOS secure SSH - PASS (tick)
  • 305.5 Checking ONOS service - PASS (tick)
  • 305.6 Starting ONOS CLI sessions - PASS (tick)
  • 305.7 Starting Mininet Topology - PASS (tick)
  • 305.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 305.9 Verify IP address assignment from hosts - PASS (tick)
  • 305.10 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE305 - PASS (tick)
  • 305.11 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE305 - PASS (tick)
  • 305.12 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 305.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 305.14 Verify IP address assignment from hosts - PASS (tick)
  • 305.15 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.16 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.17 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 305.18 Checking if ONOS CLI is ready - PASS (tick)
  • 305.19 Checking ONOS nodes - PASS (tick)
  • 305.20 Verify host IP address assignment in ONOS - PASS (tick)
  • 305.21 Verify IP address assignment from hosts - PASS (tick)
  • 305.22 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.23 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.24 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 305.25 Verify host IP address assignment in ONOS - PASS (tick)
  • 305.26 Verify IP address assignment from hosts - PASS (tick)
  • 305.27 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.28 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.29 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 305.30 Checking if ONOS CLI is ready - PASS (tick)
  • 305.31 Checking ONOS nodes - PASS (tick)
  • 305.32 Verify host IP address assignment in ONOS - PASS (tick)
  • 305.33 Verify IP address assignment from hosts - PASS (tick)
  • 305.34 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.35 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.36 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 305.37 Verify host IP address assignment in ONOS - PASS (tick)
  • 305.38 Verify IP address assignment from hosts - PASS (tick)
  • 305.39 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.40 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.41 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 305.42 Checking if ONOS CLI is ready - PASS (tick)
  • 305.43 Checking ONOS nodes - PASS (tick)
  • 305.44 Verify host IP address assignment in ONOS - PASS (tick)
  • 305.45 Verify IP address assignment from hosts - PASS (tick)
  • 305.46 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.47 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE305 - FAIL (error)
    • IPv6 connectivity failed
  • 305.48 Stopping Mininet - PASS (tick)
  • 305.49 Copying karaf logs - PASS (tick)

Case 306: Test node failures with IPv4 and IPv6 hosts (including external hosts), ONOS cluster size: 3 - FAIL

  • 306.1 Apply cell to environment - PASS (tick)
  • 306.2 Uninstalling ONOS package - PASS (tick)
  • 306.3 Installing ONOS package - PASS (tick)
  • 306.4 Set up ONOS secure SSH - PASS (tick)
  • 306.5 Checking ONOS service - PASS (tick)
  • 306.6 Starting ONOS CLI sessions - PASS (tick)
  • 306.7 Starting Mininet Topology - PASS (tick)
  • 306.8 Verify host IP address assignment in ONOS - PASS (tick)
  • 306.9 Verify IP address assignment from hosts - PASS (tick)
  • 306.10 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.11 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.12 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.13 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.14 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 306.15 Verify host IP address assignment in ONOS - PASS (tick)
  • 306.16 Verify IP address assignment from hosts - PASS (tick)
  • 306.17 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.18 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.19 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.20 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.21 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 306.22 Checking if ONOS CLI is ready - PASS (tick)
  • 306.23 Checking ONOS nodes - PASS (tick)
  • 306.24 Verify host IP address assignment in ONOS - PASS (tick)
  • 306.25 Verify IP address assignment from hosts - PASS (tick)
  • 306.26 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.27 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.28 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.29 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.30 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 306.31 Verify host IP address assignment in ONOS - PASS (tick)
  • 306.32 Verify IP address assignment from hosts - PASS (tick)
  • 306.33 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.34 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.35 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.36 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.37 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 306.38 Checking if ONOS CLI is ready - PASS (tick)
  • 306.39 Checking ONOS nodes - PASS (tick)
  • 306.40 Verify host IP address assignment in ONOS - PASS (tick)
  • 306.41 Verify IP address assignment from hosts - PASS (tick)
  • 306.42 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.43 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.44 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.45 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.46 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 306.47 Verify host IP address assignment in ONOS - PASS (tick)
  • 306.48 Verify IP address assignment from hosts - PASS (tick)
  • 306.49 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.50 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.51 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.52 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.53 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 306.54 Checking if ONOS CLI is ready - PASS (tick)
  • 306.55 Checking ONOS nodes - PASS (tick)
  • 306.56 Verify host IP address assignment in ONOS - PASS (tick)
  • 306.57 Verify IP address assignment from hosts - PASS (tick)
  • 306.58 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh1v6', u'rh11v6', u'rh2v6', u'rh22v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.59 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh1v4', u'rh2v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.60 Verify full connectivity for [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] with tag CASE306 - FAIL (error)
    • IPv4 connectivity failed
  • 306.61 Verify full connectivity for [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] with tag CASE306 - FAIL (error)
    • IPv6 connectivity failed
  • 306.62 Stopping Mininet - PASS (tick)
  • 306.63 Copying karaf logs - PASS (tick)

Case 307: Test node failures with IPv4 hosts (including external host configured with route-add command), ONOS cluster size: 3 - PASS

  • 307.1 Apply cell to environment - PASS (tick)
  • 307.2 Uninstalling ONOS package - PASS (tick)
  • 307.3 Installing ONOS package - PASS (tick)
  • 307.4 Set up ONOS secure SSH - PASS (tick)
  • 307.5 Checking ONOS service - PASS (tick)
  • 307.6 Starting ONOS CLI sessions - PASS (tick)
  • 307.7 Add static route for subnet 10.0.88.0/24 towards router interface 10.0.1.1 - PASS (tick)
  • 307.8 Starting Mininet Topology - PASS (tick)
  • 307.9 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.10 Verify IP address assignment from hosts - PASS (tick)
  • 307.11 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE307 - PASS (tick)
  • 307.12 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 307.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.14 Verify IP address assignment from hosts - PASS (tick)
  • 307.15 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE307 - PASS (tick)
  • 307.16 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 307.17 Checking if ONOS CLI is ready - PASS (tick)
  • 307.18 Checking ONOS nodes - PASS (tick)
  • 307.19 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.20 Verify IP address assignment from hosts - PASS (tick)
  • 307.21 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE307 - PASS (tick)
  • 307.22 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 307.23 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.24 Verify IP address assignment from hosts - PASS (tick)
  • 307.25 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE307 - PASS (tick)
  • 307.26 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 307.27 Checking if ONOS CLI is ready - PASS (tick)
  • 307.28 Checking ONOS nodes - PASS (tick)
  • 307.29 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.30 Verify IP address assignment from hosts - PASS (tick)
  • 307.31 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE307 - PASS (tick)
  • 307.32 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 307.33 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.34 Verify IP address assignment from hosts - PASS (tick)
  • 307.35 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE307 - PASS (tick)
  • 307.36 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 307.37 Checking if ONOS CLI is ready - PASS (tick)
  • 307.38 Checking ONOS nodes - PASS (tick)
  • 307.39 Verify host IP address assignment in ONOS - PASS (tick)
  • 307.40 Verify IP address assignment from hosts - PASS (tick)
  • 307.41 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE307 - PASS (tick)
  • 307.42 Stopping Mininet - PASS (tick)
  • 307.43 Copying karaf logs - PASS (tick)

Case 308: Test node failures with IPv6 hosts (including external host configured with route-add command), ONOS cluster size: 3 - FAIL

  • 308.1 Apply cell to environment - PASS (tick)
  • 308.2 Uninstalling ONOS package - PASS (tick)
  • 308.3 Installing ONOS package - PASS (tick)
  • 308.4 Set up ONOS secure SSH - PASS (tick)
  • 308.5 Checking ONOS service - PASS (tick)
  • 308.6 Starting ONOS CLI sessions - PASS (tick)
  • 308.7 Add static route for subnet 2000::8700/120 towards router interface 2000::101 - PASS (tick)
  • 308.8 Starting Mininet Topology - PASS (tick)
  • 308.9 Verify host IP address assignment in ONOS - PASS (tick)
  • 308.10 Verify IP address assignment from hosts - PASS (tick)
  • 308.11 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE308 - FAIL (error)
    • IPv6 connectivity failed
  • 308.12 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 308.13 Verify host IP address assignment in ONOS - PASS (tick)
  • 308.14 Verify IP address assignment from hosts - PASS (tick)
  • 308.15 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE308 - FAIL (error)
    • IPv6 connectivity failed
  • 308.16 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 308.17 Checking if ONOS CLI is ready - PASS (tick)
  • 308.18 Checking ONOS nodes - PASS (tick)
  • 308.19 Verify host IP address assignment in ONOS - PASS (tick)
  • 308.20 Verify IP address assignment from hosts - PASS (tick)
  • 308.21 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE308 - FAIL (error)
    • IPv6 connectivity failed
  • 308.22 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 308.23 Verify host IP address assignment in ONOS - PASS (tick)
  • 308.24 Verify IP address assignment from hosts - PASS (tick)
  • 308.25 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE308 - FAIL (error)
    • IPv6 connectivity failed
  • 308.26 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 308.27 Checking if ONOS CLI is ready - PASS (tick)
  • 308.28 Checking ONOS nodes - PASS (tick)
  • 308.29 Verify host IP address assignment in ONOS - PASS (tick)
  • 308.30 Verify IP address assignment from hosts - PASS (tick)
  • 308.31 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE308 - FAIL (error)
    • IPv6 connectivity failed
  • 308.32 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 308.33 Verify host IP address assignment in ONOS - PASS (tick)
  • 308.34 Verify IP address assignment from hosts - PASS (tick)
  • 308.35 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE308 - FAIL (error)
    • IPv6 connectivity failed
  • 308.36 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 308.37 Checking if ONOS CLI is ready - PASS (tick)
  • 308.38 Checking ONOS nodes - PASS (tick)
  • 308.39 Verify host IP address assignment in ONOS - PASS (tick)
  • 308.40 Verify IP address assignment from hosts - PASS (tick)
  • 308.41 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE308 - FAIL (error)
    • IPv6 connectivity failed
  • 308.42 Stopping Mininet - PASS (tick)
  • 308.43 Copying karaf logs - PASS (tick)

Case 309: Test node failures with IPv4 and IPv6 hosts (including external host configured with route-add command), ONOS cluster size: 3 - FAIL

  • 309.1 Apply cell to environment - PASS (tick)
  • 309.2 Uninstalling ONOS package - PASS (tick)
  • 309.3 Installing ONOS package - PASS (tick)
  • 309.4 Set up ONOS secure SSH - PASS (tick)
  • 309.5 Checking ONOS service - PASS (tick)
  • 309.6 Starting ONOS CLI sessions - PASS (tick)
  • 309.7 Add static route for subnet 10.0.88.0/24 towards router interface 10.0.1.1 - PASS (tick)
  • 309.8 Add static route for subnet 2000::8700/120 towards router interface 2000::101 - PASS (tick)
  • 309.9 Starting Mininet Topology - PASS (tick)
  • 309.10 Verify host IP address assignment in ONOS - PASS (tick)
  • 309.11 Verify IP address assignment from hosts - PASS (tick)
  • 309.12 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE309 - PASS (tick)
  • 309.13 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE309 - PASS (tick)
  • 309.14 Killing ONOS instances with index(es): [0] - PASS (tick)
  • 309.15 Verify host IP address assignment in ONOS - PASS (tick)
  • 309.16 Verify IP address assignment from hosts - PASS (tick)
  • 309.17 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE309 - PASS (tick)
  • 309.18 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE309 - FAIL (error)
    • IPv6 connectivity failed
  • 309.19 Recovering ONOS instances with index(es): [0] - PASS (tick)
  • 309.20 Checking if ONOS CLI is ready - PASS (tick)
  • 309.21 Checking ONOS nodes - PASS (tick)
  • 309.22 Verify host IP address assignment in ONOS - PASS (tick)
  • 309.23 Verify IP address assignment from hosts - PASS (tick)
  • 309.24 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE309 - PASS (tick)
  • 309.25 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE309 - FAIL (error)
    • IPv6 connectivity failed
  • 309.26 Killing ONOS instances with index(es): [1] - PASS (tick)
  • 309.27 Verify host IP address assignment in ONOS - PASS (tick)
  • 309.28 Verify IP address assignment from hosts - PASS (tick)
  • 309.29 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE309 - PASS (tick)
  • 309.30 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE309 - FAIL (error)
    • IPv6 connectivity failed
  • 309.31 Recovering ONOS instances with index(es): [1] - PASS (tick)
  • 309.32 Checking if ONOS CLI is ready - PASS (tick)
  • 309.33 Checking ONOS nodes - PASS (tick)
  • 309.34 Verify host IP address assignment in ONOS - PASS (tick)
  • 309.35 Verify IP address assignment from hosts - PASS (tick)
  • 309.36 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE309 - PASS (tick)
  • 309.37 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE309 - FAIL (error)
    • IPv6 connectivity failed
  • 309.38 Killing ONOS instances with index(es): [2] - PASS (tick)
  • 309.39 Verify host IP address assignment in ONOS - PASS (tick)
  • 309.40 Verify IP address assignment from hosts - PASS (tick)
  • 309.41 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE309 - PASS (tick)
  • 309.42 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE309 - FAIL (error)
    • IPv6 connectivity failed
  • 309.43 Recovering ONOS instances with index(es): [2] - PASS (tick)
  • 309.44 Checking if ONOS CLI is ready - PASS (tick)
  • 309.45 Checking ONOS nodes - PASS (tick)
  • 309.46 Verify host IP address assignment in ONOS - PASS (tick)
  • 309.47 Verify IP address assignment from hosts - PASS (tick)
  • 309.48 Verify unidirectional connectivity from [u'h1v4', u'h2v4', u'h3v4', u'h4v4', u'h5v4', u'h6v4', u'h7v4', u'h8v4', u'h9v4', u'h10v4', u'h11v4'] to [u'rh5v4'] with tag CASE309 - PASS (tick)
  • 309.49 Verify unidirectional connectivity from [u'h1v6', u'h2v6', u'h3v6', u'h4v6', u'h5v6', u'h6v6', u'h7v6', u'h8v6', u'h9v6', u'h10v6', u'h11v6'] to [u'rh5v6'] with tag CASE309 - FAIL (error)
    • IPv6 connectivity failed
  • 309.50 Stopping Mininet - PASS (tick)
  • 309.51 Copying karaf logs - PASS (tick)