The difference is that we use the IXIA tester to simulate openflow switches,and switches, total 100 switches was set and 100000 flows for each switch, the results show below.
Test Results
Flow_mode rate(P/S) Single mode(ONOS) | Flow_mode rate(P/S) Three mode(ONOS1) | Flow_mode rate(P/S) Three mode(ONOS2) | Flow_mode rate(P/S) Three mode(ONOS3) | |
---|---|---|---|---|
First | 10760 | 13112 | 12569 | 8941 |
Second | 11414 | 8383 | 7865 | 11244 |
Third | 11892 | 8558 | 7376 | 8477 |
Fourth | 12029 | 7983 | 7790 | 9028 |
Fifth | 12174 | 13387 | 13087 | 7666 |
Sixth | 11319 | 9126 | 8905 | 8335 |
Seventh | 11225 | 14442 | 13546 | 7906 |
Eighth | 12585 | 10446 | 9748 | 12318 |
Ninth | 12065 | 10456 | 9878 | 8406 |
Tenth | 10413 | 9638 | 9237 | 13580 |
Avg | 11587 | 10553 | 10000 | 9590 |
Std | 644 | 2188 | 2165 | 1939 |