commit 07e46f47e78385aa8933877d450596caf8c5897d 6de1240c890a08fec66e92869b7d7bc08d02adb5 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Sean Condon Thomas Vachuska [seantom@opennetworking.condon@microsemi.comorg]
AuthorDate: Thu Jan 31 2015:5402:53 27 2019 +0000-0800
Commit: Andrea Campanella Thomas Vachuska [andrea@opennetworkingtom@opennetworking.org]
CommitDate: Fri Mon Feb 1 114 10:1438:18 55 2019 +0000
[ONOS-7907] Glyph specified for device not used in device table or device detail boxes
--
(cherry picked from commit 794d250740dcf2bdad65ad0f5ebe473d3093a266)-0800

Removing Topology 2 from the nav menu.

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 57.1 Apply cell to environment - PASS (tick)
  • 57.2 Uninstalling Atomix - PASS (tick)
  • 57.3 Uninstalling ONOS package - PASS (tick)
  • 57.4 Installing Atomix - PASS (tick)
  • 57.5 Installing ONOS package - PASS (tick)
  • 57.6 Set up ONOS secure SSH - PASS (tick)
  • 57.7 Checking ONOS service - PASS (tick)
  • 57.8 Starting ONOS CLI sessions - PASS (tick)
  • 57.9 Checking ONOS nodes - PASS (tick)
  • 57.10 Checking ONOS applications - PASS (tick)
  • 57.11 Starting Mininet Topology - PASS (tick)
  • 57.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 57.13 Check whether all flow status are ADDED - PASS (tick)
  • 57.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 57.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 57.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS (tick)
  • 57.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS (tick)
  • 57.18 Stopping Mininet - PASS (tick)
  • 57.19 Copying karaf logs - PASS (tick)

Case 58: Bridging test between two untagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 58.1 Apply cell to environment - PASS (tick)
  • 58.2 Uninstalling Atomix - PASS (tick)
  • 58.3 Uninstalling ONOS package - PASS (tick)
  • 58.4 Installing Atomix - PASS (tick)
  • 58.5 Installing ONOS package - PASS (tick)
  • 58.6 Set up ONOS secure SSH - PASS (tick)
  • 58.7 Checking ONOS service - PASS (tick)
  • 58.8 Starting ONOS CLI sessions - PASS (tick)
  • 58.9 Checking ONOS nodes - PASS (tick)
  • 58.10 Checking ONOS applications - PASS (tick)
  • 58.11 Starting Mininet Topology - PASS (tick)
  • 58.12 Check whether the flow count is bigger than 212 - PASS (tick)FAIL (error)
    • Flow count looks wrong: False
  • 58.13 Check whether all flow status are ADDED - PASS (tick)
  • 58.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 16
  • 58.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 16
  • 58.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 45
  • 58.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)FAIL (error)
    • Flow count looks wrong: 16
  • 58.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE58 - PASS (tick)
  • 58.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE58 - PASS (tick)
  • 58.20 Stopping Mininet - PASS (tick)
  • 58.21 Copying karaf logs - PASS (tick)

...