Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.0/1044/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.0_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit ffeb196152315802e9c4519e4a6e095cec7c26cd 4862978e6adcf33049dd887e6c298a7848b9c909 (HEAD -] onos-2.0, origin/onos-2.0)
Author: Ray Milkey Andrea Campanella [ray@opennetworkingandrea@opennetworking.org]
AuthorDate: Fri Wed Feb 8 166 10:5202:25 15 2019 -0800+0100
Commit: Ray Milkey Andrea Campanella [ray@opennetworkingandrea@opennetworking.org]
CommitDate: Sun Mon Feb 10 0311 17:2558:20 46 2019 +0000
Allow Atomix fetch command to follow redirects
[ONOS-7917] Improving device description query in Netconf Device provider
--
(cherry picked from commit 79705aab230752c3f72b58a65c6e1d265c4c32857eb01712a22695fa5dc8ca234d9989969e16f182)

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 13.1 Constructing test variables - PASS (tick)
  • 13.2 Apply cell to environment - PASS (tick)
  • 13.3 Uninstalling Atomix - PASS (tick)
  • 13.4 Uninstalling ONOS package - PASS (tick)
  • 13.5 Creating ONOS package - PASS (tick)
  • 13.6 Installing Atomix - PASS (tick)
  • 13.7 Installing ONOS package - PASS (tick)
  • 13.8 Set up ONOS secure SSH - PASS (tick)
  • 13.9 Checking ONOS service - PASS (tick)
  • 13.10 Starting ONOS CLI sessions - PASS (tick)
  • 13.11 Checking ONOS nodes - PASS (tick)
  • 13.12 Checking ONOS applications - PASS (tick)
  • 13.13 Starting Mininet Topology - PASS (tick)
  • 13.14 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.15 Check whether all flow status are ADDED - PASS (tick)
  • 13.16 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_Before - PASS (tick)
  • 13.17 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 13.18 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 13.19 Check whether the flow count is bigger than 104 - PASS (tick)
  • 13.20 Check whether all flow status are ADDED - PASS (tick)
  • 13.21 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE13_After - PASS (tick)
  • 13.22 Stopping Mininet - PASS (tick)
  • 13.23 Copying karaf logs - PASS (tick)

Case 23: Changing port configuration from untagged 10 to tagged 20 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.13 Check whether all flow status are ADDED - PASS (tick)
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - PASS (tick)
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - PASS (tick)
  • 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 23.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 23.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - PASS (tick)
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling Atomix - PASS (tick)
  • 33.3 Uninstalling ONOS package - PASS (tick)
  • 33.4 Installing Atomix - PASS (tick)
  • 33.5 Installing ONOS package - PASS (tick)
  • 33.6 Set up ONOS secure SSH - PASS (tick)
  • 33.7 Checking ONOS service - PASS (tick)
  • 33.8 Starting ONOS CLI sessions - PASS (tick)
  • 33.9 Checking ONOS nodes - PASS (tick)
  • 33.10 Checking ONOS applications - PASS (tick)
  • 33.11 Starting Mininet Topology - PASS (tick)
  • 33.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.13 Check whether all flow status are ADDED - PASS (tick)
  • 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.22 Stopping Mininet - PASS (tick)
  • 33.23 Copying karaf logs - PASS (tick)

Case 43: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling Atomix - PASS (tick)
  • 43.3 Uninstalling ONOS package - PASS (tick)
  • 43.4 Installing Atomix - PASS (tick)
  • 43.5 Installing ONOS package - PASS (tick)
  • 43.6 Set up ONOS secure SSH - PASS (tick)
  • 43.7 Checking ONOS service - PASS (tick)
  • 43.8 Starting ONOS CLI sessions - PASS (tick)
  • 43.9 Checking ONOS nodes - PASS (tick)
  • 43.10 Checking ONOS applications - PASS (tick)
  • 43.11 Starting Mininet Topology - PASS (tick)
  • 43.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.13 Check whether all flow status are ADDED - PASS (tick)
  • 43.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS (tick)
  • 43.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS (tick)
  • 43.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 43.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 43.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 43.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS (tick)
  • 43.22 Stopping Mininet - PASS (tick)
  • 43.23 Copying karaf logs - PASS (tick)

...

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling Atomix - PASS (tick)
  • 113.3 Uninstalling ONOS package - PASS (tick)
  • 113.4 Installing Atomix - PASS (tick)
  • 113.5 Installing ONOS package - PASS (tick)
  • 113.6 Set up ONOS secure SSH - PASS (tick)
  • 113.7 Checking ONOS service - PASS (tick)
  • 113.8 Starting ONOS CLI sessions - PASS (tick)
  • 113.9 Checking ONOS nodes - PASS (tick)
  • 113.10 Checking ONOS applications - PASS (tick)
  • 113.11 Starting Mininet Topology - PASS (tick)
  • 113.12 Check whether the flow count is bigger than 104 - FAIL (error)
  • Flow count looks wrong: 12
  • PASS (tick)
  • 113.13 Check whether all flow status are ADDED - PASS (tick)
  • 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - FAIL (error)
    • Flow count looks wrong: 3
  • PASS (tick)
  • 113.18 Check whether the flow count is bigger than 104 - FAIL (error)
    • Flow count looks wrong: 12
  • PASS (tick)
  • 113.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.22 Stopping Mininet - PASS (tick)
  • 113.23 Copying karaf logs - PASS (tick)

...