Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.0/1052/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.0_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit 194d83dcc2417d84c232fdbbca3ed464fb8bd0b4 d678dceffc43a2d789a30379e70a0f32af8fcdb3 (HEAD -] onos-2.0, origin/onos-2.0)
Author: Arjun E K [arjun.k02@infosysCharles Chan [rascov@gmail.com]
AuthorDate: Fri Feb 8 07:47:23 2019 -0500Tue Jan 22 17:25:04 2019 -0800
Commit: Pier Luigi Ventre [pier@opennetworkingCharles Chan [charles@opennetworking.org]
CommitDate: Mon Wed Feb 18 1620 01:4114:57 06 2019 +0000
fix for service not found error
--
(cherry picked from commit cab2869c3115bcbe11f310c8b7dfdf44c76c6e5b)

Deprecate CpqD pipeliners

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 53.1 Apply cell to environment - PASS (tick)
  • 53.2 Uninstalling Atomix - PASS (tick)
  • 53.3 Uninstalling ONOS package - PASS (tick)
  • 53.4 Installing Atomix - PASS (tick)
  • 53.5 Installing ONOS package - PASS (tick)
  • 53.6 Set up ONOS secure SSH - PASS (tick)
  • 53.7 Checking ONOS service - PASS (tick)
  • 53.8 Starting ONOS CLI sessions - PASS (tick)
  • 53.9 Checking ONOS nodes - PASS (tick)
  • 53.10 Checking ONOS applications - PASS (tick)
  • 53.11 Starting Mininet Topology - PASS (tick)
  • 53.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.13 Check whether all flow status are ADDED - PASS (tick)
  • 53.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_Before - PASS (tick)
  • 53.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_Before - PASS (tick)
  • 53.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 53.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 53.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 53.19 Check whether all flow status are ADDED - PASS (tick)
  • 53.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE53_After - PASS (tick)
  • 53.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE53_After - PASS (tick)
  • 53.22 Stopping Mininet - PASS (tick)
  • 53.23 Copying karaf logs - PASS (tick)

Case 63: Changing port configuration from untagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

PASS

  • 63.1 Apply cell to environment - PASS (tick)
  • 63.2 Uninstalling Atomix - PASS (tick)
  • 63.3 Uninstalling ONOS package - PASS (tick)
  • 63.4 Installing Atomix - PASS (tick)
  • 63.5 Installing ONOS package - PASS (tick)
  • 63.6 Set up ONOS secure SSH - PASS (tick)
  • 63.7 Checking ONOS service - PASS (tick)
  • 63.8 Starting ONOS CLI sessions - PASS (tick)
  • 63.9 Checking ONOS nodes - PASS (tick)
  • 63.10 Checking ONOS applications - PASS (tick)
  • 63.11 Starting Mininet Topology - PASS (tick)
  • 63.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.13 Check whether all flow status are ADDED - PASS (tick)
  • 63.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 63.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 63.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 63.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 63.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 63.19 Check whether all flow status are ADDED - PASS (tick)
  • 63.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE63_After - PASS (tick)
  • 63.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE63_After - PASS (tick)
  • 63.22 Stopping Mininet - PASS (tick)
  • 63.23 Copying karaf logs - PASS (tick)

...

  • 83.1 Apply cell to environment - PASS (tick)
  • 83.2 Uninstalling Atomix - PASS (tick)
  • 83.3 Uninstalling ONOS package - PASS (tick)
  • 83.4 Installing Atomix - PASS (tick)
  • 83.5 Installing ONOS package - PASS (tick)
  • 83.6 Set up ONOS secure SSH - PASS (tick)
  • 83.7 Checking ONOS service - PASS (tick)
  • 83.8 Starting ONOS CLI sessions - PASS (tick)
  • 83.9 Checking ONOS nodes - PASS (tick)
  • 83.10 Checking ONOS applications - PASS (tick)
  • 83.11 Starting Mininet Topology - PASS (tick)
  • 83.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.13 Check whether all flow status are ADDED - PASS (tick)
  • 83.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_Before - PASS (tick)
  • 83.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_Before - PASS (tick)
  • 83.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 83.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 83.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 83.19 Check whether all flow status are ADDED - PASS (tick)
  • 83.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE83_After - PASS (tick)
  • 83.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE83_After - PASS (tick)
  • 83.22 Stopping Mininet - PASS (tick)
  • 83.23 Copying karaf logs - PASS (tick)

Case 93: Changing port configuration from tagged 10 to tagged 120 with native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 93.1 Apply cell to environment - PASS (tick)
  • 93.2 Uninstalling Atomix - PASS (tick)
  • 93.3 Uninstalling ONOS package - PASS (tick)
  • 93.4 Installing Atomix - PASS (tick)
  • 93.5 Installing ONOS package - PASS (tick)
  • 93.6 Set up ONOS secure SSH - PASS (tick)
  • 93.7 Checking ONOS service - PASS (tick)
  • 93.8 Starting ONOS CLI sessions - PASS (tick)
  • 93.9 Checking ONOS nodes - PASS (tick)
  • 93.10 Checking ONOS applications - PASS (tick)
  • 93.11 Starting Mininet Topology - PASS (tick)
  • 93.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.13 Check whether all flow status are ADDED - PASS (tick)
  • 93.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_Before - PASS (tick)
  • 93.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_Before - PASS (tick)
  • 93.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 93.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 93.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 93.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 93.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE93_After - PASS (tick)
  • 93.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE93_After - PASS (tick)
  • 93.22 Stopping Mininet - PASS (tick)
  • 93.23 Copying karaf logs - PASS (tick)

...