Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.15/1107/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRBridging_onos-1.15_20-builds_graph.jpg", alt="SRBridging", style="width:525px;height:350px;border:0">

commit 6c5ab65da7249c76bdec350200aceb58e5b45d0f 2a6c8e917e1b871d1c4aba24c91b2e968c2a1d59 (HEAD -] onos-1.15, origin/onos-1.15)
Author: Jian Li [pyguni@gmailSean Condon [sean.condon@microsemi.com]
AuthorDate: Mon Mar 4 1022:3916:28 20 2019 +09000000
Commit: Jian Li Sean Condon [pyguni@gmailscondo01@gmail.com]
CommitDate: Mon Mar 4 0122:4120:28 2019 +0000
Fix: resolve openstack node attribute serialization issues
[ONOS-7943] Error in topo layout overlay

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR and 3 ONOS instances - PASS

...

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Starting Mininet Topology - PASS (tick)
  • 7.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.13 Check whether all flow status are ADDED - PASS (tick)
  • 7.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 7.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 7.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - PASS (tick)
  • 7.18 Stopping Mininet - PASS (tick)
  • 7.19 Copying karaf logs - PASS (tick)

Case 8: Bridging test between two untagged hosts on vlan-untagged port, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 8.1 Apply cell to environment - PASS (tick)
  • 8.2 Uninstalling Atomix - PASS (tick)
  • 8.3 Uninstalling ONOS package - PASS (tick)
  • 8.4 Installing Atomix - PASS (tick)
  • 8.5 Installing ONOS package - PASS (tick)
  • 8.6 Set up ONOS secure SSH - PASS (tick)
  • 8.7 Checking ONOS service - PASS (tick)
  • 8.8 Starting ONOS CLI sessions - PASS (tick)
  • 8.9 Checking ONOS nodes - PASS (tick)
  • 8.10 Checking ONOS applications - PASS (tick)
  • 8.11 Starting Mininet Topology - PASS (tick)
  • 8.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 8.13 Check whether all flow status are ADDED - PASS (tick)
  • 8.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 8.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 8.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 8.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 8.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE8 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 8.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE8 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 8.20 Stopping Mininet - PASS (tick)
  • 8.21 Copying karaf logs - PASS (tick)

...