Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-2.0/1073/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric3/lastSuccessfulBuild/artifact/SRDynamicConf_onos-2.0_20-builds_graph.jpg", alt="SRDynamicConf", style="width:525px;height:350px;border:0">

commit 5854f2bf57e1f96d45624755b3302a56ecba17d1 5fe98dbcbed9df6eec0e72a07e2d716f2d35dd5a (HEAD -] onos-2.0, origin/onos-2.0)
Author: Harshada Chaundkar [Harshada_Chaundkar@comcast.comAndrea Campanella [andrea@opennetworking.org]
AuthorDate: Fri Mar 8 14:15:53 2019 -0500Mon Feb 18 17:45:01 2019 +0100
Commit: Charles Chan Andrea Campanella [rascov@gmailandrea@opennetworking.comorg]
CommitDate: Mon Tue Mar 11 1512 18:3733:08 12 2019 -0700
Fixed potential NPE in packet-stats for ipv4 tcp packets
Fix for ADVA ols with TAPI

Case 13: Changing port configuration from untagged 10 to tagged 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

...

  • 23.1 Apply cell to environment - PASS (tick)
  • 23.2 Uninstalling Atomix - PASS (tick)
  • 23.3 Uninstalling ONOS package - PASS (tick)
  • 23.4 Installing Atomix - PASS (tick)
  • 23.5 Installing ONOS package - PASS (tick)
  • 23.6 Set up ONOS secure SSH - PASS (tick)
  • 23.7 Checking ONOS service - PASS (tick)
  • 23.8 Starting ONOS CLI sessions - PASS (tick)
  • 23.9 Checking ONOS nodes - PASS (tick)
  • 23.10 Checking ONOS applications - PASS (tick)
  • 23.11 Starting Mininet Topology - PASS (tick)
  • 23.12 Check whether the flow count is bigger than 106 - FAIL (error)
  • Flow count looks wrong: 96
  • PASS (tick)
  • 23.13 Check whether all flow status are ADDED - PASS (tick)
  • 23.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE23_Before - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 23.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_Before - FAIL (error)
    • IP connectivity failed
  • PASS (tick)
  • 23 23.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 45
  • PASS (tick)
  • 23.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 19
  • PASS (tick)
  • 23.18 Check whether the flow count is bigger than 106 - FAIL (error)
    • Flow count looks wrong: 97
  • PASS (tick)
  • 23.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 23.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE23_After - PASS (tick)
  • 23.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE23_After - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 23.22 Stopping Mininet - PASS (tick)
  • 23.23 Copying karaf logs - PASS (tick)

Case 33: Changing port configuration from untagged 10 to untagged 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 33.1 Apply cell to environment - PASS (tick)
  • 33.2 Uninstalling Atomix - PASS (tick)
  • 33.3 Uninstalling ONOS package - PASS (tick)
  • 33.4 Installing Atomix - PASS (tick)
  • 33.5 Installing ONOS package - PASS (tick)
  • 33.6 Set up ONOS secure SSH - PASS (tick)
  • 33.7 Checking ONOS service - PASS (tick)
  • 33.8 Starting ONOS CLI sessions - PASS (tick)
  • 33.9 Checking ONOS nodes - PASS (tick)
  • 33.10 Checking ONOS applications - PASS (tick)
  • 33.11 Starting Mininet Topology - PASS (tick)
  • 33.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.13 Check whether all flow status are ADDED - PASS (tick)
  • 33.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_Before - PASS (tick)
  • 33.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_Before - PASS (tick)
  • 33.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 33.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 33.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 33.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 33.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE33_After - PASS (tick)
  • 33.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE33_After - PASS (tick)
  • 33.22 Stopping Mininet - PASS (tick)
  • 33.23 Copying karaf logs - PASS (tick)

Case 43: Changing port configuration from untagged 10 to tagged 20, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 43.1 Apply cell to environment - PASS (tick)
  • 43.2 Uninstalling Atomix - PASS (tick)
  • 43.3 Uninstalling ONOS package - PASS (tick)
  • 43.4 Installing Atomix - PASS (tick)
  • 43.5 Installing ONOS package - PASS (tick)
  • 43.6 Set up ONOS secure SSH - PASS (tick)
  • 43.7 Checking ONOS service - PASS (tick)
  • 43.8 Starting ONOS CLI sessions - PASS (tick)
  • 43.9 Checking ONOS nodes - PASS (tick)
  • 43.10 Checking ONOS applications - PASS (tick)
  • 43.11 Starting Mininet Topology - PASS (tick)
  • 43.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.13 Check whether all flow status are ADDED - PASS (tick)
  • 43.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE43_Before - PASS (tick)
  • 43.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_Before - PASS (tick)
  • 43.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 43.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 43.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 43.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 43.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE43_After - PASS (tick)
  • 43.21 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE43_After - PASS (tick)
  • 43.22 Stopping Mininet - PASS (tick)
  • 43.23 Copying karaf logs - PASS (tick)

...

  • 113.1 Apply cell to environment - PASS (tick)
  • 113.2 Uninstalling Atomix - PASS (tick)
  • 113.3 Uninstalling ONOS package - PASS (tick)
  • 113.4 Installing Atomix - PASS (tick)
  • 113.5 Installing ONOS package - PASS (tick)
  • 113.6 Set up ONOS secure SSH - PASS (tick)
  • 113.7 Checking ONOS service - PASS (tick)
  • 113.8 Starting ONOS CLI sessions - PASS (tick)
  • 113.9 Checking ONOS nodes - PASS (tick)
  • 113.10 Checking ONOS applications - PASS (tick)
  • 113.11 Starting Mininet Topology - PASS (tick)
  • 113.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.13 Check whether all flow status are ADDED - PASS (tick)
  • 113.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_Before - PASS (tick)
  • 113.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE113_Before - PASS (tick)
  • 113.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 113.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 113.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 113.19 Check whether all flow status are ADDED - PASS (tick)
  • 113.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE113_After - PASS (tick)
  • 113.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE113_After - PASS (tick)
  • 113.22 Stopping Mininet - PASS (tick)
  • 113.23 Copying karaf logs - PASS (tick)

Case 123: Changing port configuration from tagged 20 and native 10 to tagged 20 and native 110, with 2x2 leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 123.1 Apply cell to environment - PASS (tick)
  • 123.2 Uninstalling Atomix - PASS (tick)
  • 123.3 Uninstalling ONOS package - PASS (tick)
  • 123.4 Installing Atomix - PASS (tick)
  • 123.5 Installing ONOS package - PASS (tick)
  • 123.6 Set up ONOS secure SSH - PASS (tick)
  • 123.7 Checking ONOS service - PASS (tick)
  • 123.8 Starting ONOS CLI sessions - PASS (tick)
  • 123.9 Checking ONOS nodes - PASS (tick)
  • 123.10 Checking ONOS applications - PASS (tick)
  • 123.11 Starting Mininet Topology - PASS (tick)
  • 123.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.13 Check whether all flow status are ADDED - PASS (tick)
  • 123.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_Before - PASS (tick)
  • 123.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_Before - PASS (tick)
  • 123.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 123.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 123.18 Check whether the flow count is bigger than 104 - PASS (tick)
  • 123.19 Check whether all flow status are ADDED - PASS (tick)FAIL (error)
    • Flow status is wrong!
  • 123.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE123_After - PASS (tick)
  • 123.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE123_After - PASS (tick)
  • 123.22 Stopping Mininet - PASS (tick)
  • 123.23 Copying karaf logs - PASS (tick)

...

  • 213.1 Apply cell to environment - PASS (tick)
  • 213.2 Uninstalling Atomix - PASS (tick)
  • 213.3 Uninstalling ONOS package - PASS (tick)
  • 213.4 Installing Atomix - PASS (tick)
  • 213.5 Installing ONOS package - PASS (tick)
  • 213.6 Set up ONOS secure SSH - PASS (tick)
  • 213.7 Checking ONOS service - PASS (tick)
  • 213.8 Starting ONOS CLI sessions - PASS (tick)
  • 213.9 Checking ONOS nodes - PASS (tick)
  • 213.10 Checking ONOS applications - PASS (tick)
  • 213.11 Starting Mininet Topology - PASS (tick)
  • 213.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.13 Check whether all flow status are ADDED - PASS (tick)
  • 213.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_Before - PASS (tick)
  • 213.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_Before - PASS (tick)
  • 213.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 213.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 213.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 213.19 Check whether all flow status are ADDED - PASS (tick)
  • 213.20 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE213_After - PASS (tick)
  • 213.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE213_After - PASS (tick)
  • 213.22 Stopping Mininet - PASS (tick)
  • 213.23 Copying karaf logs - PASS (tick)

Case 223: Changing port configuration from tagged 20 and native 10 to tagged 120 and native 10, with 2x2 leaf-spine topology and 3 ONOS instances - PASS

  • 223.1 Apply cell to environment - PASS (tick)
  • 223.2 Uninstalling Atomix - PASS (tick)
  • 223.3 Uninstalling ONOS package - PASS (tick)
  • 223.4 Installing Atomix - PASS (tick)
  • 223.5 Installing ONOS package - PASS (tick)
  • 223.6 Set up ONOS secure SSH - PASS (tick)
  • 223.7 Checking ONOS service - PASS (tick)
  • 223.8 Starting ONOS CLI sessions - PASS (tick)
  • 223.9 Checking ONOS nodes - PASS (tick)
  • 223.10 Checking ONOS applications - PASS (tick)
  • 223.11 Starting Mininet Topology - PASS (tick)
  • 223.12 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.13 Check whether all flow status are ADDED - PASS (tick)
  • 223.14 Verify full connectivity for [u'h1', u'h3', u'h4'] with tag CASE223_Before - PASS (tick)
  • 223.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE223_Before - PASS (tick)
  • 223.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 223.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 223.18 Check whether the flow count is bigger than 106 - PASS (tick)
  • 223.19 Check whether all flow status are ADDED - PASS (tick)
  • 223.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE223_After - PASS (tick)
  • 223.21 Verify full connectivity for [u'h1', u'h2', u'h3'] with tag CASE223_After - PASS (tick)
  • 223.22 Stopping Mininet - PASS (tick)
  • 223.23 Copying karaf logs - PASS (tick)

Case 233: Consecutive configuration changes, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 233.1 Apply cell to environment - PASS (tick)
  • 233.2 Uninstalling Atomix - PASS (tick)
  • 233.3 Uninstalling ONOS package - PASS (tick)
  • 233.4 Installing Atomix - PASS (tick)
  • 233.5 Installing ONOS package - PASS (tick)
  • 233.6 Set up ONOS secure SSH - PASS (tick)
  • 233.7 Checking ONOS service - PASS (tick)
  • 233.8 Starting ONOS CLI sessions - PASS (tick)
  • 233.9 Checking ONOS nodes - PASS (tick)
  • 233.10 Checking ONOS applications - PASS (tick)
  • 233.11 Starting Mininet Topology - PASS (tick)
  • 233.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.13 Check whether all flow status are ADDED - PASS (tick)
  • 233.14 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_Before - PASS (tick)
  • 233.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_Before - PASS (tick)
  • 233.16 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.17 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.18 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.19 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.20 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_1 - PASS (tick)
  • 233.21 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_1 - PASS (tick)
  • 233.22 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.23 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.24 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_2 - PASS (tick)
  • 233.25 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_2 - PASS (tick)
  • 233.26 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.27 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.28 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_3 - PASS (tick)
  • 233.29 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_3 - PASS (tick)
  • 233.30 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.31 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.32 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_4 - PASS (tick)
  • 233.33 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_4 - FAIL (error)
    • IP connectivity failed
  • 233.34 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.35 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.36 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_5 - PASS (tick)
  • 233.37 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_5 - PASS (tick)
  • 233.38 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.39 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.40 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_6 - PASS (tick)
  • 233.41 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_6 - PASS (tick)
  • 233.42 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 233.43 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 233.44 Check whether the flow count is bigger than 104 - PASS (tick)
  • 233.45 Check whether all flow status are ADDED - PASS (tick)
  • 233.46 Verify full connectivity for [u'h3', u'h4'] with tag CASE233_After - PASS (tick)
  • 233.47 Verify full connectivity for [u'h1', u'h2'] with tag CASE233_After - PASS (tick)
  • 233.48 Stopping Mininet - PASS (tick)
  • 233.49 Copying karaf logs - PASS (tick)

Case 243: Changing port configuration from 10.0.2.254/24 to 10.0.6.254/24, with 2x2 leaf-spine topology and 3 ONOS instances - FAIL

  • 243.1 Apply cell to environment - PASS (tick)
  • 243.2 Uninstalling Atomix - PASS (tick)
  • 243.3 Uninstalling ONOS package - PASS (tick)
  • 243.4 Installing Atomix - PASS (tick)
  • 243.5 Installing ONOS package - PASS (tick)
  • 243.6 Set up ONOS secure SSH - PASS (tick)
  • 243.7 Checking ONOS service - PASS (tick)
  • 243.8 Starting ONOS CLI sessions - PASS (tick)
  • 243.9 Checking ONOS nodes - PASS (tick)
  • 243.10 Checking ONOS applications - PASS (tick)
  • 243.11 Starting Mininet Topology - PASS (tick)
  • 243.12 Check whether the flow count is bigger than 104 - PASS (tick)
  • 243.13 Check whether all flow status are ADDED - PASS (tick)
  • 243.14 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_Before - FAIL (error)
    • IP connectivity failed
  • 243.15 Check whether the flow count of device of:0000000000000001 is bigger than 52 - PASS (tick)
  • 243.16 Check whether the flow count of device of:0000000000000002 is bigger than 52 - PASS (tick)
  • 243.17 Check whether the flow count is bigger than 104 - PASS (tick)
  • 243.18 Check whether all flow status are ADDED - PASS (tick)
  • 243.19 Verify full connectivity for [u'h1', u'h2', u'h5'] with tag CASE243_After - FAIL (error)
    • IP connectivity failed
  • 243.20 Stopping Mininet - PASS (tick)
  • 243.21 Copying karaf logs - PASS (tick)