Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.15/1291/

...

  • 65.1 Apply cell to environment - PASS (tick)
  • 65.2 Uninstalling Atomix - PASS (tick)
  • 65.3 Uninstalling ONOS package - PASS (tick)
  • 65.4 Installing Atomix - PASS (tick)
  • 65.5 Installing ONOS package - PASS (tick)
  • 65.6 Set up ONOS secure SSH - PASS (tick)
  • 65.7 Checking ONOS service - PASS (tick)
  • 65.8 Starting ONOS CLI sessions - PASS (tick)
  • 65.9 Checking ONOS nodes - PASS (tick)
  • 65.10 Checking ONOS applications - PASS (tick)
  • 65.11 Starting Mininet Topology - PASS (tick)
  • 65.12 Check whether the flow count is bigger than 28 - PASS (tick)
  • 65.13 Check whether all flow status are ADDED - PASS (tick)
  • 65.14 Check whether the flow count of device of:0000000000000001 is bigger than 28 - PASS (tick)
  • 65.15 Verify full connectivity for [u'h1', u'h2'] with tag CASE65 - PASS (tick)
  • 65.16 Stopping Mininet - PASS (tick)
  • 65.17 Copying karaf logs - PASS (tick)

Case 66: Bridging test between two tagged hosts with different vlan id, with dual-homed ToR and 3 ONOS instances -

...

PASS

  • 66.1 Apply cell to environment - PASS (tick)
  • 66.2 Uninstalling Atomix - PASS (tick)
  • 66.3 Uninstalling ONOS package - PASS (tick)
  • 66.4 Installing Atomix - PASS (tick)
  • 66.5 Installing ONOS package - PASS (tick)
  • 66.6 Set up ONOS secure SSH - PASS (tick)
  • 66.7 Checking ONOS service - PASS (tick)
  • 66.8 Starting ONOS CLI sessions - PASS (tick)
  • 66.9 Checking ONOS nodes - PASS (tick)
  • 66.10 Checking ONOS applications - PASS (tick)
  • 66.11 Starting Mininet Topology - PASS (tick)
  • 66.12 Check whether the flow count is bigger than 74 - FAIL (error)
    • Flow count looks wrong: 32
  • PASS (tick)
  • 66.13 Check whether all flow status are ADDED - PASS (tick)
  • 66.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
    • Flow count looks wrong: 16
  • PASS (tick)
  • 66.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 16
  • PASS (tick)
  • 66.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE66 - PASS (tick)
  • 66.17 Stopping Mininet - PASS (tick)
  • 66.18 Copying karaf logs - PASS (tick)

...