Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric4/lastSuccessfulBuild/artifact/SRDynamic_master_20-builds_graph.jpg", alt="SRDynamic", style="width:525px;height:350px;border:0">

commit 95d1465424bc5b0ddeef2186b4bcc493e797f94a 7d13b59ecf0968dae20a3ccee7c59cad3f21f66d (HEAD -] master, origin/master, origin/HEAD)
Author: ONOS Jenkins User [jenkins@onlab.usJian Li [pyguni@gmail.com]
AuthorDate: Thu Jul 1 19:25:42 2021 +0000Fri Sep 24 15:08:53 2021 +0900
Commit: ONOS Jenkins User [jenkins@onlab.usJian Li [pyguni@gmail.com]
CommitDate: Thu Jul 1 19:25:42 Fri Sep 24 06:51:38 2021 +0000
Starting snapshot 2.6.0-SNAPSHOT
Fix: make protocol field optional in kubevirt load balancer
--
(cherry picked from commit 70d491cba5689d69708568f693b92432ebe52ba5)

Case 1: Bridging and Routing sanity test with 2x2 leaf-spine topologyand 1 nodes. - FAIL

...

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling Atomix - PASS (tick)
  • 1.4 Uninstalling ONOS package - PASS (tick)
  • 1.5 Creating ONOS package - PASS (tick)
  • 1.6 Installing Atomix - PASS (tick)
  • 1.7 Installing ONOS package - PASS (tick)
  • 1.8 Set up ONOS secure SSH - PASS (tick)
  • 1.9 Checking ONOS service - PASS (tick)
  • 1.10 Starting ONOS CLI sessions - PASS (tick)
  • 1.11 Checking ONOS nodes - PASS (tick)
  • 1.12 Checking ONOS applications - PASS (tick)
  • 1.13 Set logging levels - PASS (tick)
  • 1.14 Set ONOS configurations - PASS (tick)
  • 1.15 Starting Mininet Topology - PASS (tick)
  • 1.16 Check whether the flow count is >= 116 - PASS (tick)
  • 1.17 Check whether all flow status are ADDED - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.21 Pushing new configuration - No Result (warning)
  • 1.22 Pushing new configuration - No Result (warning)
  • 1.23 Check whether the flow count is >= 140 - PASS (tick)
  • 1.24 Check whether all flow status are ADDED - PASS (tick)
  • 1.25 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', 'in1', 'out1'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.26 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.27 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.28 Verify full connectivity for ['olt1', 'vsg1'] with tag CASE1 - PASS (tick)
  • 1.29 Stopping Mininet - PASS (tick)
  • 1.30 Copying karaf logs - PASS (tick)

...