commit 86b869e1657ec09472a18e008e386b7cba82dc4f a18900c28c4da57b901a75d28f8c61ba1c675f4d (HEAD -] onos-2.5, origin/onos-2.5)
Author: pierventre [pier@opennetworking.org]
AuthorDate: Mon Wed Apr 21 12 23:1257:16 47 2021 +0200
Commit: pierventre Pier Luigi Ventre [pier@opennetworking.org]
CommitDate: Thu Apr 22 17Mon May 3 11:03:41 :07 2021 +02000000

[AETHER-1516] Barefoot/bmv2 drivers are never loaded1550] Add additional trace logs in P4RT SB

Case 5: Bridging test between two untagged hosts on vlan-untagged port, with single ToR, ovs switches and 3 ONOS instances - PASS

...

  • 6.1 Apply cell to environment - PASS (tick)
  • 6.2 Uninstalling Atomix - PASS (tick)
  • 6.3 Uninstalling ONOS package - PASS (tick)
  • 6.4 Installing Atomix - PASS (tick)
  • 6.5 Installing ONOS package - PASS (tick)
  • 6.6 Set up ONOS secure SSH - PASS (tick)
  • 6.7 Checking ONOS service - PASS (tick)
  • 6.8 Starting ONOS CLI sessions - PASS (tick)
  • 6.9 Checking ONOS nodes - PASS (tick)
  • 6.10 Checking ONOS applications - PASS (tick)
  • 6.11 Set logging levels - PASS (tick)
  • 6.12 Set ONOS configurations - PASS (tick)
  • 6.13 Starting Mininet Topology - PASS (tick)
  • 6.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 6.15 Check whether all flow status are ADDED - PASS (tick)
  • 6.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 6.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 6.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE6 - PASS (tick)
  • 6.19 Stopping Mininet - PASS (tick)
  • 6.20 Copying karaf logs - PASS (tick)

Case 7: Bridging test between two untagged hosts on vlan-untagged port, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 7.1 Apply cell to environment - PASS (tick)
  • 7.2 Uninstalling Atomix - PASS (tick)
  • 7.3 Uninstalling ONOS package - PASS (tick)
  • 7.4 Installing Atomix - PASS (tick)
  • 7.5 Installing ONOS package - PASS (tick)
  • 7.6 Set up ONOS secure SSH - PASS (tick)
  • 7.7 Checking ONOS service - PASS (tick)
  • 7.8 Starting ONOS CLI sessions - PASS (tick)
  • 7.9 Checking ONOS nodes - PASS (tick)
  • 7.10 Checking ONOS applications - PASS (tick)
  • 7.11 Set logging levels - PASS (tick)
  • 7.12 Set ONOS configurations - PASS (tick)
  • 7.13 Starting Mininet Topology - PASS (tick)
  • 7.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 7.15 Check whether all flow status are ADDED - FAIL (error)
  • Flow status is wrong!
  • PASS (tick)
  • 7.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 7.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 23
  • PASS (tick)
  • 7.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE7 - PASS (tick)
  • 7.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE7 - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 7.20 Stopping Mininet - PASS (tick)
  • 7.21 Copying karaf logs - PASS (tick)

...

  • 37.1 Apply cell to environment - PASS (tick)
  • 37.2 Uninstalling Atomix - PASS (tick)
  • 37.3 Uninstalling ONOS package - PASS (tick)
  • 37.4 Installing Atomix - PASS (tick)
  • 37.5 Installing ONOS package - PASS (tick)
  • 37.6 Set up ONOS secure SSH - PASS (tick)
  • 37.7 Checking ONOS service - PASS (tick)
  • 37.8 Starting ONOS CLI sessions - PASS (tick)
  • 37.9 Checking ONOS nodes - PASS (tick)
  • 37.10 Checking ONOS applications - PASS (tick)
  • 37.11 Set logging levels - PASS (tick)
  • 37.12 Set ONOS configurations - PASS (tick)
  • 37.13 Starting Mininet Topology - PASS (tick)
  • 37.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 37.15 Check whether all flow status are ADDED - PASS (tick)
  • 37.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 37.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 37.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE37 - PASS (tick)
  • 37.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE37 - PASS (tick)
  • 37.20 Stopping Mininet - PASS (tick)
  • 37.21 Copying karaf logs - PASS (tick)

Case 38: Bridging test between two untagged hosts, one on vlan-untagged port and the other on vlan-native port, with 2x4 dual-homed leaf-spine topology, ovs switches and 3 ONOS instances -

...

FAIL

  • 38.1 Apply cell to environment - PASS (tick)
  • 38.2 Uninstalling Atomix - PASS (tick)
  • 38.3 Uninstalling ONOS package - PASS (tick)
  • 38.4 Installing Atomix - PASS (tick)
  • 38.5 Installing ONOS package - PASS (tick)
  • 38.6 Set up ONOS secure SSH - PASS (tick)
  • 38.7 Checking ONOS service - PASS (tick)
  • 38.8 Starting ONOS CLI sessions - PASS (tick)
  • 38.9 Checking ONOS nodes - PASS (tick)
  • 38.10 Checking ONOS applications - PASS (tick)
  • 38.11 Set logging levels - PASS (tick)
  • 38.12 Set ONOS configurations - PASS (tick)
  • 38.13 Starting Mininet Topology - PASS (tick)
  • 38.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 38.15 Check whether all flow status are ADDED - PASS (tick)
  • 38.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 38.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 38.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 38.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 38.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE38 - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 38.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE38 - PASS (tick)
  • 38.22 Stopping Mininet - PASS (tick)
  • 38.23 Copying karaf logs - PASS (tick)

...

  • 48.1 Apply cell to environment - PASS (tick)
  • 48.2 Uninstalling Atomix - PASS (tick)
  • 48.3 Uninstalling ONOS package - PASS (tick)
  • 48.4 Installing Atomix - PASS (tick)
  • 48.5 Installing ONOS package - PASS (tick)
  • 48.6 Set up ONOS secure SSH - PASS (tick)
  • 48.7 Checking ONOS service - PASS (tick)
  • 48.8 Starting ONOS CLI sessions - PASS (tick)
  • 48.9 Checking ONOS nodes - PASS (tick)
  • 48.10 Checking ONOS applications - PASS (tick)
  • 48.11 Set logging levels - PASS (tick)
  • 48.12 Set ONOS configurations - PASS (tick)
  • 48.13 Starting Mininet Topology - PASS (tick)
  • 48.14 Check whether the flow count is bigger than 212 - PASS (tick)
  • 48.15 Check whether all flow status are ADDED - PASS (tick)
  • 48.16 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 48.17 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 48.18 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 48.19 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 48.20 Verify full connectivity for [u'h1', u'h2'] with tag CASE48 - PASS (tick)
  • 48.21 Verify full connectivity for [u'h3', u'h4'] with tag CASE48 - PASS (tick)
  • 48.22 Stopping Mininet - PASS (tick)
  • 48.23 Copying karaf logs - PASS (tick)

Case 55: Bridging test between two untagged hosts with different vlan id, with single ToR, ovs switches and 3 ONOS instances -

...

PASS

  • 55.1 Apply cell to environment - PASS (tick)
  • 55.2 Uninstalling Atomix - PASS (tick)
  • 55.3 Uninstalling ONOS package - PASS (tick)
  • 55.4 Installing Atomix - PASS (tick)
  • 55.5 Installing ONOS package - PASS (tick)
  • 55.6 Set up ONOS secure SSH - PASS (tick)
  • 55.7 Checking ONOS service - PASS (tick)
  • 55.8 Starting ONOS CLI sessions - PASS (tick)
  • 55.9 Checking ONOS nodes - PASS (tick)
  • 55.10 Checking ONOS applications - PASS (tick)
  • 55.11 Set logging levels - PASS (tick)
  • 55.12 Set ONOS configurations - PASS (tick)
  • 55.13 Starting Mininet Topology - PASS (tick)
  • 55.14 Check whether the flow count is bigger than 28 - FAIL (error)
    • Flow count looks wrong; found 21, expecting at least 28
  • PASS (tick)
  • 55.15 Check whether all flow status are ADDED - PASS (tick)
  • 55.16 Check whether the flow count of device of:0000000000000001 is bigger than 28 - FAIL (error)
    • Flow count looks wrong: 21
  • PASS (tick)
  • 55.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE55 - PASS (tick)
  • 55.18 Stopping Mininet - PASS (tick)
  • 55.19 Copying karaf logs - PASS (tick)

...

  • 56.1 Apply cell to environment - PASS (tick)
  • 56.2 Uninstalling Atomix - PASS (tick)
  • 56.3 Uninstalling ONOS package - PASS (tick)
  • 56.4 Installing Atomix - PASS (tick)
  • 56.5 Installing ONOS package - PASS (tick)
  • 56.6 Set up ONOS secure SSH - PASS (tick)
  • 56.7 Checking ONOS service - PASS (tick)
  • 56.8 Starting ONOS CLI sessions - PASS (tick)
  • 56.9 Checking ONOS nodes - PASS (tick)
  • 56.10 Checking ONOS applications - PASS (tick)
  • 56.11 Set logging levels - PASS (tick)
  • 56.12 Set ONOS configurations - PASS (tick)
  • 56.13 Starting Mininet Topology - PASS (tick)
  • 56.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 56.15 Check whether all flow status are ADDED - PASS (tick)
  • 56.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 56.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 56.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE56 - PASS (tick)
  • 56.19 Stopping Mininet - PASS (tick)
  • 56.20 Copying karaf logs - PASS (tick)

Case 57: Bridging test between two untagged hosts with different vlan id, with 2x2 leaf-spine topology, ovs switches and 3 ONOS instances -

...

PASS

  • 57.1 Apply cell to environment - PASS (tick)
  • 57.2 Uninstalling Atomix - PASS (tick)
  • 57.3 Uninstalling ONOS package - PASS (tick)
  • 57.4 Installing Atomix - PASS (tick)
  • 57.5 Installing ONOS package - PASS (tick)
  • 57.6 Set up ONOS secure SSH - PASS (tick)
  • 57.7 Checking ONOS service - PASS (tick)
  • 57.8 Starting ONOS CLI sessions - PASS (tick)
  • 57.9 Checking ONOS nodes - PASS (tick)
  • 57.10 Checking ONOS applications - PASS (tick)
  • 57.11 Set logging levels - PASS (tick)
  • 57.12 Set ONOS configurations - PASS (tick)
  • 57.13 Starting Mininet Topology - PASS (tick)
  • 57.14 Check whether the flow count is bigger than 74 - PASS (tick)
  • 57.15 Check whether all flow status are ADDED - PASS (tick)
  • 57.16 Check whether the flow count of device of:0000000000000001 is bigger than 37 - FAIL (error)
  • Flow count looks wrong: 19
  • PASS (tick)
  • 57.17 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 57.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE57 - PASS (tick)
  • 57.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE57 - PASS (tick)
  • 57.20 Stopping Mininet - PASS (tick)
  • 57.21 Copying karaf logs - PASS (tick)

...