Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Published from Jenkins build: https://jenkins.onosproject.org/job/SR-pipeline-1.13/140/

...

HTML
<img src="https://jenkins.onosproject.org/view/QA/job/postjob-Fabric2/lastSuccessfulBuild/artifact/SRClusterRestart_onos-1.13_20-builds_graph.jpg", alt="SRClusterRestart", style="width:525px;height:350px;border:0">

commit 248e7cd94b80596dc2f4b41a93fb985e811ce411 1dbadbd3baf3ac1906a85f3d0d0731e0da8c3b57 (HEAD -] onos-1.13, origin/onos-1.13)
Author: Jonathan Hart Charles Chan [jono@opennetworkingrascov@gmail.orgcom]
AuthorDate: Tue Thu Aug 21 1723 14:5330:02 33 2018 -0700
Commit: Jonathan Hart Charles Chan [jono@opennetworkingrascov@gmail.orgcom]
CommitDate: Thu Aug 23 0030 15:04:35 :30 2018 +0000
Allow LLDP traps to be installed on OLTs-0700

Remove NextId from internal stores when the NextObj fails

Case 1: Cluster Restart test with 2x2 Leaf-spine - FAIL

...

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling ONOS package - PASS (tick)
  • 1.4 Creating ONOS package - PASS (tick)
  • 1.5 Installing ONOS package - PASS (tick)
  • 1.6 Set up ONOS secure SSH - PASS (tick)
  • 1.7 Checking ONOS service - PASS (tick)
  • 1.8 Starting ONOS CLI sessions - PASS (tick)
  • 1.9 Checking ONOS nodes - PASS (tick)
  • 1.10 Checking ONOS applications - PASS (tick)
  • 1.11 Starting Mininet Topology - PASS (tick)
  • 1.12 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.13 Check whether all flow status are ADDED - PASS (tick)
  • 1.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.15 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.16 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.17 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.21 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.22 Checking if ONOS CLI is ready - PASS (tick)
  • 1.23 Checking if ONOS CLI is ready - PASS (tick)
  • 1.24 Checking if ONOS CLI is ready - PASS (tick)
  • 1.25 Checking ONOS nodes - PASS (tick)
  • 1.26 Check number of topology elements - PASS (tick)
  • 1.27 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.28 Check whether all flow status are ADDED - PASS (tick)
  • 1.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 1.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)FAIL (error)
    • IP connectivity failed
  • 1.32 Stopping Mininet - PASS (tick)
  • 1.33 Copying karaf logs - PASS (tick)

...

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling ONOS package - PASS (tick)
  • 2.3 Creating ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Set up ONOS secure SSH - PASS (tick)
  • 2.6 Checking ONOS service - PASS (tick)
  • 2.7 Starting ONOS CLI sessions - PASS (tick)
  • 2.8 Checking ONOS nodes - PASS (tick)
  • 2.9 Checking ONOS applications - PASS (tick)
  • 2.10 Starting Mininet Topology - PASS (tick)
  • 2.11 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.12 Check whether all flow status are ADDED - PASS (tick)
  • 2.13 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.14 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.15 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.16 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.20 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.21 Checking if ONOS CLI is ready - PASS (tick)
  • 2.22 Checking if ONOS CLI is ready - PASS (tick)
  • 2.23 Checking if ONOS CLI is ready - PASS (tick)
  • 2.24 Checking ONOS nodes - PASS (tick)
  • 2.25 Check number of topology elements - PASS (tick)
  • 2.26 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.27 Check whether all flow status are ADDED - PASS (tick)
  • 2.28 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.29 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 2.30 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - FAIL (error)
  • IP connectivity failed
  • PASS (tick)
  • 2.31 Stopping Mininet - PASS (tick)
  • 2.32 Copying karaf logs - PASS (tick)

...