Have questions? Stuck? Please check our FAQ for some common questions and answers.

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 20 Next »

SRClusterRestart at 02 Sep 2018 03:46:45

SRClusterRestart

commit 1dbadbd3baf3ac1906a85f3d0d0731e0da8c3b57 (HEAD -] onos-1.13, origin/onos-1.13)
Author: Charles Chan [rascov@gmail.com]
AuthorDate: Thu Aug 23 14:30:33 2018 -0700
Commit: Charles Chan [rascov@gmail.com]
CommitDate: Thu Aug 30 15:04:35 2018 -0700

Remove NextId from internal stores when the NextObj fails

Case 1: Cluster Restart test with 2x2 Leaf-spine - FAIL

  • 1.1 Constructing test variables - PASS (tick)
  • 1.2 Apply cell to environment - PASS (tick)
  • 1.3 Uninstalling ONOS package - PASS (tick)
  • 1.4 Creating ONOS package - PASS (tick)
  • 1.5 Installing ONOS package - PASS (tick)
  • 1.6 Set up ONOS secure SSH - PASS (tick)
  • 1.7 Checking ONOS service - PASS (tick)
  • 1.8 Starting ONOS CLI sessions - PASS (tick)
  • 1.9 Checking ONOS nodes - PASS (tick)
  • 1.10 Checking ONOS applications - PASS (tick)
  • 1.11 Starting Mininet Topology - PASS (tick)
  • 1.12 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.13 Check whether all flow status are ADDED - PASS (tick)
  • 1.14 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1 - FAIL (error)
    • IP connectivity failed
  • 1.15 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1 - PASS (tick)
  • 1.16 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1 - PASS (tick)
  • 1.17 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.18 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.19 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - PASS (tick)
  • 1.20 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - PASS (tick)
  • 1.21 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 1.22 Checking if ONOS CLI is ready - PASS (tick)
  • 1.23 Checking if ONOS CLI is ready - PASS (tick)
  • 1.24 Checking if ONOS CLI is ready - PASS (tick)
  • 1.25 Checking ONOS nodes - PASS (tick)
  • 1.26 Check number of topology elements - PASS (tick)
  • 1.27 Check whether the flow count is bigger than 116 - PASS (tick)
  • 1.28 Check whether all flow status are ADDED - PASS (tick)
  • 1.29 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.30 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.31 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE1_Failure - FAIL (error)
    • IP connectivity failed
  • 1.32 Stopping Mininet - PASS (tick)
  • 1.33 Copying karaf logs - PASS (tick)

Case 2: Cluster Restart test with 4x4 Leaf-spine - FAIL

  • 2.1 Apply cell to environment - PASS (tick)
  • 2.2 Uninstalling ONOS package - PASS (tick)
  • 2.3 Creating ONOS package - PASS (tick)
  • 2.4 Installing ONOS package - PASS (tick)
  • 2.5 Set up ONOS secure SSH - PASS (tick)
  • 2.6 Checking ONOS service - PASS (tick)
  • 2.7 Starting ONOS CLI sessions - PASS (tick)
  • 2.8 Checking ONOS nodes - PASS (tick)
  • 2.9 Checking ONOS applications - PASS (tick)
  • 2.10 Starting Mininet Topology - PASS (tick)
  • 2.11 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.12 Check whether all flow status are ADDED - PASS (tick)
  • 2.13 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2 - FAIL (error)
    • IP connectivity failed
  • 2.14 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2 - PASS (tick)
  • 2.15 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2 - PASS (tick)
  • 2.16 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.17 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.20 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 2.21 Checking if ONOS CLI is ready - PASS (tick)
  • 2.22 Checking if ONOS CLI is ready - PASS (tick)
  • 2.23 Checking if ONOS CLI is ready - PASS (tick)
  • 2.24 Checking ONOS nodes - PASS (tick)
  • 2.25 Check number of topology elements - PASS (tick)
  • 2.26 Check whether the flow count is bigger than 350 - PASS (tick)
  • 2.27 Check whether all flow status are ADDED - PASS (tick)
  • 2.28 Verify full connectivity for [u'h1', u'h2', u'h3', u'h4', u'h5', u'h6', u'h7', u'h8'] with tag CASE2_Failure - FAIL (error)
    • IP connectivity failed
  • 2.29 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE2_Failure - PASS (tick)
  • 2.30 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE2_Failure - PASS (tick)
  • 2.31 Stopping Mininet - PASS (tick)
  • 2.32 Copying karaf logs - PASS (tick)

Case 3: Cluster Restart test with single switch - PASS

  • 3.1 Apply cell to environment - PASS (tick)
  • 3.2 Uninstalling ONOS package - PASS (tick)
  • 3.3 Creating ONOS package - PASS (tick)
  • 3.4 Installing ONOS package - PASS (tick)
  • 3.5 Set up ONOS secure SSH - PASS (tick)
  • 3.6 Checking ONOS service - PASS (tick)
  • 3.7 Starting ONOS CLI sessions - PASS (tick)
  • 3.8 Checking ONOS nodes - PASS (tick)
  • 3.9 Checking ONOS applications - PASS (tick)
  • 3.10 Starting Mininet Topology - PASS (tick)
  • 3.11 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.12 Check whether all flow status are ADDED - PASS (tick)
  • 3.13 Verify full connectivity for [u'h1', u'h2'] with tag CASE3 - PASS (tick)
  • 3.14 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3 - PASS (tick)
  • 3.15 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3 - PASS (tick)
  • 3.16 Killing ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.17 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.18 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS (tick)
  • 3.19 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS (tick)
  • 3.20 Recovering ONOS instances with index(es): [0, 1, 2] - PASS (tick)
  • 3.21 Checking if ONOS CLI is ready - PASS (tick)
  • 3.22 Checking if ONOS CLI is ready - PASS (tick)
  • 3.23 Checking if ONOS CLI is ready - PASS (tick)
  • 3.24 Checking ONOS nodes - PASS (tick)
  • 3.25 Check number of topology elements - PASS (tick)
  • 3.26 Check whether the flow count is bigger than 15 - PASS (tick)
  • 3.27 Check whether all flow status are ADDED - PASS (tick)
  • 3.28 Verify full connectivity for [u'h1', u'h2'] with tag CASE3_Failure - PASS (tick)
  • 3.29 Verify full connectivity for [u'olt10', u'vsg10'] with tag CASE3_Failure - PASS (tick)
  • 3.30 Verify full connectivity for [u'olt5', u'vsg5'] with tag CASE3_Failure - PASS (tick)
  • 3.31 Stopping Mininet - PASS (tick)
  • 3.32 Copying karaf logs - PASS (tick)
  • No labels