  • 17.1 Apply cell to environment - PASS (tick)
  • 17.2 Uninstalling Atomix - PASS (tick)
  • 17.3 Uninstalling ONOS package - PASS (tick)
  • 17.4 Installing Atomix - PASS (tick)
  • 17.5 Installing ONOS package - PASS (tick)
  • 17.6 Set up ONOS secure SSH - PASS (tick)
  • 17.7 Checking ONOS service - PASS (tick)
  • 17.8 Starting ONOS CLI sessions - PASS (tick)
  • 17.9 Checking ONOS nodes - PASS (tick)
  • 17.10 Checking ONOS applications - PASS (tick)
  • 17.11 Starting Mininet Topology - PASS (tick)
  • 17.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 17.13 Check whether all flow status are ADDED - PASS (tick)
  • 17.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 17.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 17.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE17 - PASS (tick)
  • 17.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE17 - PASS (tick)
  • 17.18 Stopping Mininet - PASS (tick)
  • 17.19 Copying karaf logs - PASS (tick)

Case 18: Bridging test between two tagged hosts, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

FAIL

  • 18.1 Apply cell to environment - PASS (tick)
  • 18.2 Uninstalling Atomix - PASS (tick)
  • 18.3 Uninstalling ONOS package - PASS (tick)
  • 18.4 Installing Atomix - PASS (tick)
  • 18.5 Installing ONOS package - PASS (tick)
  • 18.6 Set up ONOS secure SSH - PASS (tick)FAIL (error)
    • Failed to secure ssh
  • 18.7 Checking ONOS service - PASS (tick)
  • 18.8 Starting ONOS CLI sessions - PASS (tick)
  • 18.9 Checking ONOS nodes - PASS (tick)
  • 18.10 Checking ONOS applications - PASS (tick)
  • 18.11 Starting Mininet Topology - PASS (tick)
  • 18.12 Check whether the flow count is bigger than 212 - PASS (tick)
  • 18.13 Check whether all flow status are ADDED - PASS (tick)
  • 18.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - PASS (tick)
  • 18.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - PASS (tick)
  • 18.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - PASS (tick)
  • 18.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - PASS (tick)
  • 18.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE18 - PASS (tick)
  • 18.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE18 - PASS (tick)
  • 18.20 Stopping Mininet - PASS (tick)
  • 18.21 Copying karaf logs - PASS (tick)

...

  • 77.1 Apply cell to environment - PASS (tick)
  • 77.2 Uninstalling Atomix - PASS (tick)
  • 77.3 Uninstalling ONOS package - PASS (tick)
  • 77.4 Installing Atomix - PASS (tick)
  • 77.5 Installing ONOS package - PASS (tick)
  • 77.6 Set up ONOS secure SSH - PASS (tick)
  • 77.7 Checking ONOS service - PASS (tick)
  • 77.8 Starting ONOS CLI sessions - PASS (tick)
  • 77.9 Checking ONOS nodes - PASS (tick)
  • 77.10 Checking ONOS applications - PASS (tick)
  • 77.11 Starting Mininet Topology - PASS (tick)
  • 77.12 Check whether the flow count is bigger than 74 - PASS (tick)
  • 77.13 Check whether all flow status are ADDED - PASS (tick)
  • 77.14 Check whether the flow count of device of:0000000000000001 is bigger than 37 - PASS (tick)
  • 77.15 Check whether the flow count of device of:0000000000000002 is bigger than 37 - PASS (tick)
  • 77.16 Verify full connectivity for [u'h1', u'h2'] with tag CASE77 - PASS (tick)
  • 77.17 Verify full connectivity for [u'h3', u'h4'] with tag CASE77 - PASS (tick)
  • 77.18 Stopping Mininet - PASS (tick)
  • 77.19 Copying karaf logs - PASS (tick)

Case 78: Bridging test between untagged and tagged hosts with different vlan id, with 2x4 dual-homed leaf-spine topology and 3 ONOS instances -

...

PASS

  • 78.1 Apply cell to environment - PASS (tick)
  • 78.2 Uninstalling Atomix - PASS (tick)
  • 78.3 Uninstalling ONOS package - PASS (tick)
  • 78.4 Installing Atomix - PASS (tick)
  • 78.5 Installing ONOS package - PASS (tick)
  • 78.6 Set up ONOS secure SSH - PASS (tick)
  • 78.7 Checking ONOS service - PASS (tick)
  • 78.8 Starting ONOS CLI sessions - PASS (tick)
  • 78.9 Checking ONOS nodes - PASS (tick)
  • 78.10 Checking ONOS applications - PASS (tick)
  • 78.11 Starting Mininet Topology - PASS (tick)
  • 78.12 Check whether the flow count is bigger than 212 - FAIL (error)
  • Flow count looks wrong: 114
  • PASS (tick)
  • 78.13 Check whether all flow status are ADDED - PASS (tick)
  • 78.14 Check whether the flow count of device of:0000000000000001 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 78.15 Check whether the flow count of device of:0000000000000002 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 78.16 Check whether the flow count of device of:0000000000000003 is bigger than 53 - FAIL (error)
    • Flow count looks wrong: 18
  • PASS (tick)
  • 78.17 Check whether the flow count of device of:0000000000000004 is bigger than 53 - FAIL (error)
  • Flow count looks wrong: 18
  • PASS (tick)
  • 78.18 Verify full connectivity for [u'h1', u'h2'] with tag CASE78 - PASS (tick)
  • 78.19 Verify full connectivity for [u'h3', u'h4'] with tag CASE78 - PASS (tick)
  • 78.20 Stopping Mininet - PASS (tick)
  • 78.21 Copying karaf logs - PASS (tick)